These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
808 related items for PubMed ID: 17441460
1. [Usefulness of an earphone-type infrared tympanic thermometer for intraoperative core temperature monitoring]. Hayase T, Yamakage M, Kiya T, Satoh J, Namiki A. Masui; 2007 Apr; 56(4):459-63. PubMed ID: 17441460 [Abstract] [Full Text] [Related]
2. The usefulness of an earphone-type infrared tympanic thermometer for intraoperative core temperature monitoring. Kiya T, Yamakage M, Hayase T, Satoh J, Namiki A. Anesth Analg; 2007 Dec; 105(6):1688-92, table of contents. PubMed ID: 18042868 [Abstract] [Full Text] [Related]
3. [Usefulness of a noncontact continuous tympanic thermometer in patients undergoing cardiac surgery using an artificial heart-lung machine]. Yamagishi A, Toyama Y, Tobise F, Ichimiya T, Iwasaki H. Masui; 2012 Aug; 61(8):896-900. PubMed ID: 22991822 [Abstract] [Full Text] [Related]
4. [Relative accuracy of Thermoscan PRO-1 in patients under general anesthesia]. Harioka T, Nomura K, Ito T. Masui; 1994 Sep; 43(9):1395-400. PubMed ID: 7967043 [Abstract] [Full Text] [Related]
5. [Utility of an infrared ear thermometer as an intraoperative core temperature monitor]. Kamada Y, Miyamoto N, Yamakage M, Tsujiguchi N, Namiki A. Masui; 1999 Oct; 48(10):1121-5. PubMed ID: 10554504 [Abstract] [Full Text] [Related]
6. [Temperature measurement in the ear canal: comparison of an infrared thermometer with conventional temperature probes and evaluation of clinical factors on infrared measurement]. Rohrberg M, Fritz U, Weyland W, Braun U. Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Jul; 32(7):409-13. PubMed ID: 9340028 [Abstract] [Full Text] [Related]
7. [Reading children's temperatures with the tympanic infrared thermometer and the rectal mercury thermometer: equally good results in the emergency room]. Draaisma JM, van Lemmen RJ, de Jong AA, Doesburg W. Ned Tijdschr Geneeskd; 1997 May 10; 141(19):938-41. PubMed ID: 9340539 [Abstract] [Full Text] [Related]
8. The usefulness of an earphone-type infrared tympanic thermometer during cardiac surgery with cardiopulmonary bypass: clinical report. Masamune T, Yamauchi M, Wada K, Iwashita H, Okuyama K, Ino H, Yamakage M, Ishiyama T, Matsukawa T. J Anesth; 2011 Aug 10; 25(4):576-9. PubMed ID: 21519927 [Abstract] [Full Text] [Related]
9. [Measurement of the body temperature of adults by rectal digital thermometer and the infrared tympanic thermometer: equally good results in the department of internal medicine]. Postma CT, Wahjudi J, Kamps JA, de Boo T, van der Meer JW. Ned Tijdschr Geneeskd; 1997 May 10; 141(19):942-6. PubMed ID: 9340540 [Abstract] [Full Text] [Related]
10. [Use of modified infrared aural canal thermometers during cardiac surgery]. Kawamura A, Matsukawa T, Ozaki M, Okuyama K, Ohkawa I, Kumazawa T. Masui; 2000 Jul 10; 49(7):792-5. PubMed ID: 10933038 [Abstract] [Full Text] [Related]
11. [The ear thermometer; not a good replacement for the rectal thermometer]. Van Berkel M, Jooren MC, Timmermans A, van der Velde EA. Ned Tijdschr Geneeskd; 1998 Sep 19; 142(38):2102-5. PubMed ID: 9856224 [Abstract] [Full Text] [Related]
12. [Can ear temperature measurement be used in a hospital?]. Nordås TG, Leiren S, Hansen KS. Tidsskr Nor Laegeforen; 2005 Oct 20; 125(20):2763-5. PubMed ID: 16244675 [Abstract] [Full Text] [Related]
13. Measurement accuracy of fever by tympanic and axillary thermometry. Devrim I, Kara A, Ceyhan M, Tezer H, Uludağ AK, Cengiz AB, Yiğitkanl I, Seçmeer G. Pediatr Emerg Care; 2007 Jan 20; 23(1):16-9. PubMed ID: 17228215 [Abstract] [Full Text] [Related]
14. "Deep-forehead" temperature correlates well with blood temperature. Harioka T, Matsukawa T, Ozaki M, Nomura K, Sone T, Kakuyama M, Toda H. Can J Anaesth; 2000 Oct 20; 47(10):980-3. PubMed ID: 11032273 [Abstract] [Full Text] [Related]
15. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people. Khorshid L, Eşer I, Zaybak A, Yapucu U. J Clin Nurs; 2005 Apr 20; 14(4):496-500. PubMed ID: 15807757 [Abstract] [Full Text] [Related]
16. Temperature measurement: comparison of non-invasive methods used in adult critical care. Farnell S, Maxwell L, Tan S, Rhodes A, Philips B. J Clin Nurs; 2005 May 20; 14(5):632-9. PubMed ID: 15840078 [Abstract] [Full Text] [Related]
17. [Infrared tympanic thermometry compared to mercury thermometers]. Valle PC, Kildahl-Andersen O, Steinvoll K. Tidsskr Nor Laegeforen; 2000 Jan 10; 120(1):15-7. PubMed ID: 10815472 [Abstract] [Full Text] [Related]
18. Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting. Freed GL, Fraley JK. Pediatrics; 1992 Mar 10; 89(3):384-6. PubMed ID: 1741208 [Abstract] [Full Text] [Related]
19. Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery. Robinson J, Charlton J, Seal R, Spady D, Joffres MR. Can J Anaesth; 1998 Apr 10; 45(4):317-23. PubMed ID: 9597204 [Abstract] [Full Text] [Related]
20. [A new medium sized probe of the non-tactile type for tympanic membrane temperature monitoring]. Nishiyama T, Hanaoka K. Masui; 1996 Sep 10; 45(9):1164-7. PubMed ID: 8905957 [Abstract] [Full Text] [Related] Page: [Next] [New Search]