These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode. Wu BY, Hou SH, Yin F, Li J, Zhao ZX, Huang JD, Chen Q. Biosens Bioelectron; 2007 Jan 15; 22(6):838-44. PubMed ID: 16675215 [Abstract] [Full Text] [Related]
3. Direct electrochemistry and electrocatalysis of hemoglobin in poly-3-hydroxybutyrate membrane. Ma X, Liu X, Xiao H, Li G. Biosens Bioelectron; 2005 Mar 15; 20(9):1836-42. PubMed ID: 15681201 [Abstract] [Full Text] [Related]
5. Direct electrochemistry of hemoglobin entrapped in cyanoethyl cellulose film and its electrocatalysis to nitric oxide. Jia S, Fei J, Zhou J, Chen X, Meng J. Biosens Bioelectron; 2009 Jun 15; 24(10):3049-54. PubMed ID: 19375300 [Abstract] [Full Text] [Related]
6. An amperometric biosensor based on hemoglobin immobilized in poly(epsilon-caprolactone) film and its application. Zheng W, Li J, Zheng YF. Biosens Bioelectron; 2008 May 15; 23(10):1562-6. PubMed ID: 18282699 [Abstract] [Full Text] [Related]
7. Direct electrochemistry of hemoglobin in PHEA and its catalysis to H2O2. Lu Q, Zhou T, Hu S. Biosens Bioelectron; 2007 Jan 15; 22(6):899-904. PubMed ID: 16621505 [Abstract] [Full Text] [Related]
8. Direct electrochemistry of hemoglobin on carbonized titania nanotubes and its application in a sensitive reagentless hydrogen peroxide biosensor. Guo C, Hu F, Li CM, Shen PK. Biosens Bioelectron; 2008 Dec 01; 24(4):825-30. PubMed ID: 18722103 [Abstract] [Full Text] [Related]
9. A new film for the fabrication of an unmediated H2O2 biosensor. Xu Y, Peng W, Liu X, Li G. Biosens Bioelectron; 2004 Oct 15; 20(3):533-7. PubMed ID: 15494236 [Abstract] [Full Text] [Related]
10. Quaternary ammonium functionalized clay film electrodes modified with polyphenol oxidase for the sensitive detection of catechol. Mbouguen JK, Ngameni E, Walcarius A. Biosens Bioelectron; 2007 Sep 30; 23(2):269-75. PubMed ID: 17537626 [Abstract] [Full Text] [Related]
11. Immobilization of hemoglobin on electrodeposited cobalt-oxide nanoparticles: direct voltammetry and electrocatalytic activity. Salimi A, Hallaj R, Soltanian S. Biophys Chem; 2007 Nov 30; 130(3):122-31. PubMed ID: 17825977 [Abstract] [Full Text] [Related]
12. A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode. Cao S, Yuan R, Chai Y, Zhang L, Li X, Gao F. Bioprocess Biosyst Eng; 2007 Mar 30; 30(2):71-8. PubMed ID: 17242931 [Abstract] [Full Text] [Related]
14. Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode. Quan D, Min DG, Cha GS, Nam H. Bioelectrochemistry; 2006 Oct 30; 69(2):267-75. PubMed ID: 16713751 [Abstract] [Full Text] [Related]
15. Electrochemical behavior of biocatalytical composite based on heme-proteins, didodecyldimethylammonium bromide and room-temperature ionic liquid. Xu Y, Hu C, Hu S. Anal Chim Acta; 2010 Mar 17; 663(1):19-26. PubMed ID: 20172091 [Abstract] [Full Text] [Related]
16. A novel hydrogen peroxide sensor based on the direct electron transfer of horseradish peroxidase immobilized on silica-hydroxyapatite hybrid film. Wang B, Zhang JJ, Pan ZY, Tao XQ, Wang HS. Biosens Bioelectron; 2009 Jan 01; 24(5):1141-5. PubMed ID: 18707863 [Abstract] [Full Text] [Related]
17. Electrocatalytic oxidation of NADH with Meldola's blue functionalized carbon nanotubes electrodes. Zhu L, Zhai J, Yang R, Tian C, Guo L. Biosens Bioelectron; 2007 May 15; 22(11):2768-73. PubMed ID: 17267199 [Abstract] [Full Text] [Related]
18. Direct mediatorless electron transport between the monolayer of photosystem II and poly(mercapto-p-benzoquinone) modified gold electrode--new design of biosensor for herbicide detection. Maly J, Masojidek J, Masci A, Ilie M, Cianci E, Foglietti V, Vastarella W, Pilloton R. Biosens Bioelectron; 2005 Dec 15; 21(6):923-32. PubMed ID: 16257662 [Abstract] [Full Text] [Related]
19. Glucose biosensor based on multi-wall carbon nanotubes and screen printed carbon electrodes. Guan WJ, Li Y, Chen YQ, Zhang XB, Hu GQ. Biosens Bioelectron; 2005 Sep 15; 21(3):508-12. PubMed ID: 16076441 [Abstract] [Full Text] [Related]
20. A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment. Yang J, Yang T, Feng Y, Jiao K. Anal Biochem; 2007 Jun 01; 365(1):24-30. PubMed ID: 17420003 [Abstract] [Full Text] [Related] Page: [Next] [New Search]