These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


523 related items for PubMed ID: 17507138

  • 1. Does compression-only cardiopulmonary resuscitation generate adequate passive ventilation during cardiac arrest?
    Deakin CD, O'Neill JF, Tabor T.
    Resuscitation; 2007 Oct; 75(1):53-9. PubMed ID: 17507138
    [Abstract] [Full Text] [Related]

  • 2. Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (P(ET)CO2) during CPR in out-of-hospital cardiac arrest (OHCA).
    Axelsson C, Karlsson T, Axelsson AB, Herlitz J.
    Resuscitation; 2009 Oct; 80(10):1099-103. PubMed ID: 19716640
    [Abstract] [Full Text] [Related]

  • 3. Arterial blood gases during basic life support of human cardiac arrest victims.
    Pytte M, Dorph E, Sunde K, Kramer-Johansen J, Wik L, Steen PA.
    Resuscitation; 2008 Apr; 77(1):35-8. PubMed ID: 18035475
    [Abstract] [Full Text] [Related]

  • 4. Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest.
    Timerman S, Cardoso LF, Ramires JA, Halperin H.
    Resuscitation; 2004 Jun; 61(3):273-80. PubMed ID: 15172705
    [Abstract] [Full Text] [Related]

  • 5. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP, Pirrallo RG, Yannopoulos D, Klein JP, von Briesen C, Sparks CW, Deja KA, Conrad CJ, Kitscha DJ, Provo TA, Lurie KG.
    Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
    [Abstract] [Full Text] [Related]

  • 6. Comparison of chest compression only and standard cardiopulmonary resuscitation for out-of-hospital cardiac arrest in Singapore.
    Ong ME, Ng FS, Anushia P, Tham LP, Leong BS, Ong VY, Tiah L, Lim SH, Anantharaman V.
    Resuscitation; 2008 Aug; 78(2):119-26. PubMed ID: 18502559
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Treatment of out-of-hospital cardiac arrest with LUCAS, a new device for automatic mechanical compression and active decompression resuscitation.
    Steen S, Sjöberg T, Olsson P, Young M.
    Resuscitation; 2005 Oct; 67(1):25-30. PubMed ID: 16159692
    [Abstract] [Full Text] [Related]

  • 9. Do we hyperventilate cardiac arrest patients?
    O'Neill JF, Deakin CD.
    Resuscitation; 2007 Apr; 73(1):82-5. PubMed ID: 17289248
    [Abstract] [Full Text] [Related]

  • 10. Quality of cardiopulmonary resuscitation before and during transport in out-of-hospital cardiac arrest.
    Olasveengen TM, Wik L, Steen PA.
    Resuscitation; 2008 Feb; 76(2):185-90. PubMed ID: 17728039
    [Abstract] [Full Text] [Related]

  • 11. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation.
    Rubertsson S, Karlsten R.
    Resuscitation; 2005 Jun; 65(3):357-63. PubMed ID: 15919574
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Increased chest compression to ventilation ratio improves delivery of CPR.
    Hostler D, Rittenberger JC, Roth R, Callaway CW.
    Resuscitation; 2007 Sep; 74(3):446-52. PubMed ID: 17383069
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. Passive oxygen insufflation is superior to bag-valve-mask ventilation for witnessed ventricular fibrillation out-of-hospital cardiac arrest.
    Bobrow BJ, Ewy GA, Clark L, Chikani V, Berg RA, Sanders AB, Vadeboncoeur TF, Hilwig RW, Kern KB.
    Ann Emerg Med; 2009 Nov; 54(5):656-662.e1. PubMed ID: 19660833
    [Abstract] [Full Text] [Related]

  • 17. Reducing ventilation frequency during cardiopulmonary resuscitation in a porcine model of cardiac arrest.
    Yannopoulos D, Tang W, Roussos C, Aufderheide TP, Idris AH, Lurie KG.
    Respir Care; 2005 May; 50(5):628-35. PubMed ID: 15871757
    [Abstract] [Full Text] [Related]

  • 18. [The effect of the external chest compression appliance (AutoPulse) on cardiac arrest in the emergency department and influence on blood gas and N-terminal B-type natriuretic peptide].
    Liu QY, Li CS.
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2010 Nov; 22(11):660-2. PubMed ID: 21122199
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Cardiopulmonary resuscitation by chest compression alone or with mouth-to-mouth ventilation.
    Hallstrom A, Cobb L, Johnson E, Copass M.
    N Engl J Med; 2000 May 25; 342(21):1546-53. PubMed ID: 10824072
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 27.