These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


162 related items for PubMed ID: 17675331

  • 1. GFR determination in adults with a single-sample iohexol plasma clearance method based on the mean sojourn time.
    Gref M, Karp K.
    Nephrol Dial Transplant; 2007 Nov; 22(11):3166-73. PubMed ID: 17675331
    [Abstract] [Full Text] [Related]

  • 2. Chromium-51-EDTA clearance in adults with a single-plasma sample.
    Mårtensson J, Groth S, Rehling M, Gref M.
    J Nucl Med; 1998 Dec; 39(12):2131-7. PubMed ID: 9867156
    [Abstract] [Full Text] [Related]

  • 3. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.
    Gref MC, Karp KH.
    Nucl Med Commun; 2009 Mar; 30(3):202-5. PubMed ID: 19262281
    [Abstract] [Full Text] [Related]

  • 4. Suitability of a simplified technique based on iohexol for decentralized measurement of glomerular filtration rate.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Scand J Urol Nephrol; 2008 Mar; 42(5):472-80. PubMed ID: 18609287
    [Abstract] [Full Text] [Related]

  • 5. Slope-only glomerular filtration rate and single-sample glomerular filtration rate as measurements of the ratio of glomerular filtration rate to extracellular fluid volume.
    Peters AM, Glass DM, Bird NJ.
    Nephrology (Carlton); 2010 Apr; 15(3):281-7. PubMed ID: 20470295
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Association between glomerular filtration rate and extracellular fluid volume in normal subjects and patients with renal impairment.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Scand J Clin Lab Invest; 2008 Apr; 68(1):39-49. PubMed ID: 18224556
    [Abstract] [Full Text] [Related]

  • 8. Glomerular filtration rate estimation by use of a correction formula for slope-intercept plasma iohexol clearance in cats.
    Finch NC, Syme HM, Elliott J, Peters AM, Gerritsen R, Croubels S, Heiene R.
    Am J Vet Res; 2011 Dec; 72(12):1652-9. PubMed ID: 22126694
    [Abstract] [Full Text] [Related]

  • 9. Iohexol clearance for GFR-determination in renal failure--single or multiple plasma sampling?
    Sterner G, Frennby B, Hultberg B, Almen T.
    Nephrol Dial Transplant; 1996 Mar; 11(3):521-5. PubMed ID: 8671824
    [Abstract] [Full Text] [Related]

  • 10. Effect of extracellular fluid volume on single-sample measurement of glomerular filtration rate.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Nephrol Dial Transplant; 2009 Jan; 24(1):104-8. PubMed ID: 18713943
    [Abstract] [Full Text] [Related]

  • 11. Validation of a new plasma cystatin C-based formula and the Modification of Diet in Renal Disease creatinine-based formula for determination of glomerular filtration rate.
    Sterner G, Björk J, Carlson J, Grubb A, Nyman U.
    Scand J Urol Nephrol; 2009 Jan; 43(3):242-9. PubMed ID: 19291590
    [Abstract] [Full Text] [Related]

  • 12. Estimation of glomerular filtration rate via 2- and 4-sample plasma clearance of iohexol and creatinine in clinically normal cats.
    Heiene R, Reynolds BS, Bexfield NH, Larsen S, Gerritsen RJ.
    Am J Vet Res; 2009 Feb; 70(2):176-85. PubMed ID: 19231948
    [Abstract] [Full Text] [Related]

  • 13. Indexing glomerular filtration rate to suit children.
    Bird NJ, Henderson BL, Lui D, Ballinger JR, Peters AM.
    J Nucl Med; 2003 Jul; 44(7):1037-43. PubMed ID: 12843217
    [Abstract] [Full Text] [Related]

  • 14. [Validity of iohexol clearance in patients with chronic renal failure and normal renal function in comparison to (99m)Tc-DTPA-clearance].
    Wiendieck E, Hartung R, Fünfstück R, Keil E, Gottschild D, Stein G.
    Dtsch Med Wochenschr; 2003 Jan 17; 128(3):76-80. PubMed ID: 12529836
    [Abstract] [Full Text] [Related]

  • 15. Glomerular filtration rate in dogs as estimated via plasma clearance of inulin and iohexol and use of limited-sample methods.
    Heiene R, Eliassen KA, Risøen U, Neal LA, Cowgill LD.
    Am J Vet Res; 2010 Sep 17; 71(9):1100-7. PubMed ID: 20807152
    [Abstract] [Full Text] [Related]

  • 16. Extracellular distribution volumes of hydrophilic solutes used to measure the glomerular filtration rate: comparison between chromium-51-EDTA and iohexol.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Physiol Meas; 2007 Feb 17; 28(2):223-34. PubMed ID: 17237593
    [Abstract] [Full Text] [Related]

  • 17. New sampling strategy using a Bayesian approach to assess iohexol clearance in kidney transplant recipients.
    Benz-de Bretagne I, Le Guellec C, Halimi JM, Gatault P, Barbet C, Alnajjar A, Büchler M, Lebranchu Y, Andres CR, Vourcʼh P, Blasco H.
    Ther Drug Monit; 2012 Jun 17; 34(3):289-97. PubMed ID: 22585184
    [Abstract] [Full Text] [Related]

  • 18. Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: use of two independent markers and an independent arbiter.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Nucl Med Commun; 2007 Sep 17; 28(9):711-8. PubMed ID: 17667750
    [Abstract] [Full Text] [Related]

  • 19. Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects.
    Bird NJ, Peters C, Michell AR, Peters AM.
    Nephrol Dial Transplant; 2008 Jun 17; 23(6):1902-9. PubMed ID: 18364371
    [Abstract] [Full Text] [Related]

  • 20. The use of iohexol clearance to determine GFR in patients with severe chronic renal failure--a comparison between different clearance techniques.
    Frennby B, Sterner G, Almén T, Hagstam KE, Hultberg B, Jacobsson L.
    Clin Nephrol; 1995 Jan 17; 43(1):35-46. PubMed ID: 7697934
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.