These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


182 related items for PubMed ID: 17683730

  • 21.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 22.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 23. Determination of silver in nano-plastic food packaging by microwave digestion coupled with inductively coupled plasma atomic emission spectrometry or inductively coupled plasma mass spectrometry.
    Lin QB, Li B, Song H, Wu HJ.
    Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2011 Aug; 28(8):1123-8. PubMed ID: 21790489
    [Abstract] [Full Text] [Related]

  • 24. Rapid determination of uranium isotopes in urine by inductively coupled plasma-mass spectrometry.
    Shi Y, Dai X, Collins R, Kramer-Tremblay S.
    Health Phys; 2011 Aug; 101(2):148-53. PubMed ID: 21709502
    [Abstract] [Full Text] [Related]

  • 25. Development and validation of an inductively coupled plasma mass spectrometry method with optimized microwave-assisted sample digestion for the determination of platinum at ultratrace levels in plasma and ultrafiltrate plasma.
    Breda M, Maffini M, Mangia A, Mucchino C, Musci M.
    J Pharm Biomed Anal; 2008 Sep 29; 48(2):435-9. PubMed ID: 18508222
    [Abstract] [Full Text] [Related]

  • 26.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 27. Inductively coupled plasma mass spectrometric determination of molybdenum in urine.
    Minoia C, Gatti A, Aprea C, Ronchi A, Sciarra G, Turci R, Bettinelli M.
    Rapid Commun Mass Spectrom; 2002 Sep 29; 16(13):1313-9. PubMed ID: 12112259
    [Abstract] [Full Text] [Related]

  • 28. Validation of an inductively coupled plasma mass spectrometry (ICP-MS) method for the determination of cerium, strontium, and titanium in ceramic materials used in radiological dispersal devices (RDDs).
    Packer AP, Larivière D, Li C, Chen M, Fawcett A, Nielsen K, Mattson K, Chatt A, Scriver C, Erhardt LS.
    Anal Chim Acta; 2007 Apr 11; 588(2):166-72. PubMed ID: 17386806
    [Abstract] [Full Text] [Related]

  • 29.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31. Renal dysfunction induced by long-term exposure to depleted uranium in rats.
    Zhu G, Xiang X, Chen X, Wang L, Hu H, Weng S.
    Arch Toxicol; 2009 Jan 11; 83(1):37-46. PubMed ID: 18594794
    [Abstract] [Full Text] [Related]

  • 32.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 33. Rare earth elements determined in Antarctic ice by inductively coupled plasma--time of flight, quadrupole and sector field-mass spectrometry: An inter-comparison study.
    Dick D, Wegner A, Gabrielli P, Ruth U, Barbante C, Kriews M.
    Anal Chim Acta; 2008 Jul 28; 621(2):140-7. PubMed ID: 18573377
    [Abstract] [Full Text] [Related]

  • 34. Production date determination of uranium-oxide materials by inductively coupled plasma mass spectrometry.
    Varga Z, Surányi G.
    Anal Chim Acta; 2007 Sep 05; 599(1):16-23. PubMed ID: 17765059
    [Abstract] [Full Text] [Related]

  • 35. Analysis of the contrast agent Magnevist and its transmetalation products in blood plasma by capillary electrophoresis/electrospray ionization time-of-flight mass spectrometry.
    Künnemeyer J, Terborg L, Nowak S, Telgmann L, Tokmak F, Krämer BK, Günsel A, Wiesmüller GA, Waldeck J, Bremer C, Karst U.
    Anal Chem; 2009 May 01; 81(9):3600-7. PubMed ID: 19338293
    [Abstract] [Full Text] [Related]

  • 36. Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels.
    Zheng J, Yamada M.
    Talanta; 2006 Jul 15; 69(5):1246-53. PubMed ID: 18970710
    [Abstract] [Full Text] [Related]

  • 37. [Interest and limits of inductively coupled plasma mass spectrometry (ICP-MS) for urinary diagnosis of radionuclide internal contamination].
    Lecompte Y, Bohand S, Laroche P, Cazoulat A.
    Ann Biol Clin (Paris); 2013 Jul 15; 71(3):269-81. PubMed ID: 23747664
    [Abstract] [Full Text] [Related]

  • 38. Synthesis of salicylaldehyde-modified mesoporous silica and its application as a new sorbent for separation, preconcentration and determination of uranium by inductively coupled plasma atomic emission spectrometry.
    Jamali MR, Assadi Y, Shemirani F, Hosseini MR, Kozani RR, Masteri-Farahani M, Salavati-Niasari M.
    Anal Chim Acta; 2006 Oct 02; 579(1):68-73. PubMed ID: 17723729
    [Abstract] [Full Text] [Related]

  • 39. Speciation of vanadium in water with quinine modified resin micro-column separation/preconcentration and their determination by fluorination assisted electrothermal vaporization (FETV)-inductively coupled plasma optical emission spectrometry (ICP-OES).
    Wu Y, Jiang Z, Hu B.
    Talanta; 2005 Oct 15; 67(4):854-61. PubMed ID: 18970250
    [Abstract] [Full Text] [Related]

  • 40. Determination of low amounts of platinum in environmental and biological materials using thermospray nebulization inductively coupled plasma-mass spectrometry.
    Parent M, Vanhoe H, Moens L, Dams R.
    Anal Bioanal Chem; 1996 Mar 15; 354(5-6):664-7. PubMed ID: 15067467
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 10.