These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


251 related items for PubMed ID: 1773763

  • 1. Guidelines for energy-efficient coils: coils designed for magnetic stimulation of the heart.
    Mouchawar GA, Nyenhuis JA, Bourland JD, Geddes LA.
    Electroencephalogr Clin Neurophysiol Suppl; 1991; 43():255-67. PubMed ID: 1773763
    [Abstract] [Full Text] [Related]

  • 2. Toroidal coil models for transcutaneous magnetic stimulation of nerves.
    Carbunaru R, Durand DM.
    IEEE Trans Biomed Eng; 2001 Apr; 48(4):434-41. PubMed ID: 11322531
    [Abstract] [Full Text] [Related]

  • 3. Magnetic coil design considerations for functional magnetic stimulation.
    Lin VW, Hsiao IN, Dhaka V.
    IEEE Trans Biomed Eng; 2000 May; 47(5):600-10. PubMed ID: 10851804
    [Abstract] [Full Text] [Related]

  • 4. Marked differences in the thermal characteristics of figure-of-eight shaped coils used for repetitive transcranial magnetic stimulation.
    Weyh T, Wendicke K, Mentschel C, Zantow H, Siebner HR.
    Clin Neurophysiol; 2005 Jun; 116(6):1477-86. PubMed ID: 15978511
    [Abstract] [Full Text] [Related]

  • 5. Electric field properties of two commercial figure-8 coils in TMS: calculation of focality and efficiency.
    Thielscher A, Kammer T.
    Clin Neurophysiol; 2004 Jul; 115(7):1697-708. PubMed ID: 15203072
    [Abstract] [Full Text] [Related]

  • 6. A 3-D differential coil design for localized magnetic stimulation.
    Hsu KH, Durand DM.
    IEEE Trans Biomed Eng; 2001 Oct; 48(10):1162-8. PubMed ID: 11585040
    [Abstract] [Full Text] [Related]

  • 7. [Improvement of coils used in functional magnetic stimulation].
    Wang Y, Shen Q, Jiang D.
    Space Med Med Eng (Beijing); 2001 Aug; 14(4):261-3. PubMed ID: 11681338
    [Abstract] [Full Text] [Related]

  • 8. Analysis of efficiency of magnetic stimulation.
    Hsu KH, Nagarajan SS, Durand DM.
    IEEE Trans Biomed Eng; 2003 Nov; 50(11):1276-85. PubMed ID: 14619998
    [Abstract] [Full Text] [Related]

  • 9. Three-dimensional distribution of the electric field induced in the brain by transcranial magnetic stimulation using figure-8 and deep H-coils.
    Roth Y, Amir A, Levkovitz Y, Zangen A.
    J Clin Neurophysiol; 2007 Feb; 24(1):31-8. PubMed ID: 17277575
    [Abstract] [Full Text] [Related]

  • 10. Improved coil design for functional magnetic stimulation of expiratory muscles.
    Hsiao IN, Lin VW.
    IEEE Trans Biomed Eng; 2001 Jun; 48(6):684-94. PubMed ID: 11396598
    [Abstract] [Full Text] [Related]

  • 11. Frequency-related effects in the optimization of coils for the magnetic stimulation of the nervous system.
    Ravazzani P, Ruohonen J, Tognola G, Anfosso F, Ollikainen M, Ilmoniemi RJ, Grandori F.
    IEEE Trans Biomed Eng; 2002 May; 49(5):463-71. PubMed ID: 12002178
    [Abstract] [Full Text] [Related]

  • 12. Magnetic nerve stimulation: the effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output.
    Barker AT, Garnham CW, Freeston IL.
    Electroencephalogr Clin Neurophysiol Suppl; 1991 May; 43():227-37. PubMed ID: 1773760
    [Abstract] [Full Text] [Related]

  • 13. Magnetic-based microfluidic platform for biomolecular separation.
    Ramadan Q, Samper V, Poenar D, Yu C.
    Biomed Microdevices; 2006 Jun; 8(2):151-8. PubMed ID: 16688574
    [Abstract] [Full Text] [Related]

  • 14. Theoretical and practical performance of magnetic stimulators and coils.
    Sgro J, Stanton P, Emerson R.
    Electroencephalogr Clin Neurophysiol Suppl; 1991 Jun; 43():279-83. PubMed ID: 1773765
    [Abstract] [Full Text] [Related]

  • 15. [Changes in magnetic coil orientation affect the stimulation effects of human peripheral nerve].
    Sun SJ.
    Fukuoka Igaku Zasshi; 1996 Mar; 87(3):66-76. PubMed ID: 8727356
    [Abstract] [Full Text] [Related]

  • 16. A novel electric design for electromagnetic stimulation--the Slinky coil.
    Ren C, Tarjan PP, Popović DB.
    IEEE Trans Biomed Eng; 1995 Sep; 42(9):918-25. PubMed ID: 7558066
    [Abstract] [Full Text] [Related]

  • 17. Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils.
    Salinas FS, Lancaster JL, Fox PT.
    Phys Med Biol; 2007 May 21; 52(10):2879-92. PubMed ID: 17473357
    [Abstract] [Full Text] [Related]

  • 18. Cylindrical tissue model for magnetic field stimulation of neurons: effects of coil geometry.
    Esselle KP, Stuchly MA.
    IEEE Trans Biomed Eng; 1995 Sep 21; 42(9):934-41. PubMed ID: 7558068
    [Abstract] [Full Text] [Related]

  • 19. Practical induction heating coil designs for clinical hyperthermia with ferromagnetic implants.
    Stauffer PR, Sneed PK, Hashemi H, Phillips TL.
    IEEE Trans Biomed Eng; 1994 Jan 21; 41(1):17-28. PubMed ID: 8200664
    [Abstract] [Full Text] [Related]

  • 20. Multichannel magnetic stimulation system design considering mutual couplings among the stimulation coils.
    Han BH, Chun IK, Lee SC, Lee SY.
    IEEE Trans Biomed Eng; 2004 May 21; 51(5):812-7. PubMed ID: 15132507
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 13.