These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. The influence of electrode placement over the innervation zone on electromyographic amplitude and mean power frequency versus isokinetic torque relationships. Beck TW, Housh TJ, Mielke M, Cramer JT, Weir JP, Malek MH, Johnson GO. J Neurosci Methods; 2007 May 15; 162(1-2):72-83. PubMed ID: 17275093 [Abstract] [Full Text] [Related]
5. Electrode shift and normalization reduce the innervation zone's influence on EMG. Beck TW, Housh TJ, Cramer JT, Malek MH, Mielke M, Hendrix R, Weir JP. Med Sci Sports Exerc; 2008 Jul 15; 40(7):1314-22. PubMed ID: 18580413 [Abstract] [Full Text] [Related]
6. The effects of the innervation zone and interelectrode distance on the patterns of responses for electromyographic amplitude and mean power frequency versus isometric torque for the vastus lateralis muscle. Beck TW, Housh TJ, Cramer JT, Malek MH, Mielke M, Hendrix R. Electromyogr Clin Neurophysiol; 2008 Jul 15; 48(1):13-25. PubMed ID: 18338531 [Abstract] [Full Text] [Related]
7. The effects of interelectrode distance over the innervation zone and normalization on the electromyographic amplitude and mean power frequency versus concentric, eccentric, and isometric torque relationships for the vastus lateralis muscle. Beck TW, Housh TJ, Cramer JT, Weir JP. J Electromyogr Kinesiol; 2009 Apr 15; 19(2):219-31. PubMed ID: 17884581 [Abstract] [Full Text] [Related]
8. The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle. Beck TW, Housh TJ, Cramer JT, Weir JP. J Electromyogr Kinesiol; 2008 Apr 15; 18(2):317-28. PubMed ID: 17174107 [Abstract] [Full Text] [Related]
10. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii. Beck TW, Housh TJ, Johnson GO, Weir JP, Cramer JT, Coburn JW, Malek MH. J Electromyogr Kinesiol; 2005 Oct 15; 15(5):482-95. PubMed ID: 15935960 [Abstract] [Full Text] [Related]
12. The effects of parallel versus perpendicular electrode orientations on EMG amplitude and mean power frequency from the biceps brachii. Zuniga J, Housh TJ, Camic CL, Hendrix CR, Mielke M, Schmidt RJ, Johnson GO. Electromyogr Clin Neurophysiol; 2010 Mar 15; 50(2):87-96. PubMed ID: 20405784 [Abstract] [Full Text] [Related]
15. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during incremental cycle ergometry. Malek MH, Housh TJ, Coburn JW, Weir JP, Schmidt RJ, Beck TW. J Neurosci Methods; 2006 Mar 15; 151(2):139-47. PubMed ID: 16122806 [Abstract] [Full Text] [Related]