These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
451 related items for PubMed ID: 17785313
1. Evaluation of the BioPlex 2200 ANA screen for the detection of antinuclear antibodies and comparison with conventional methods. Desplat-Jego S, Bardin N, Larida B, Sanmarco M. Ann N Y Acad Sci; 2007 Aug; 1109():245-55. PubMed ID: 17785313 [Abstract] [Full Text] [Related]
2. Evaluation of the BioPlex 2200 ANA screen: analysis of 510 healthy subjects: incidence of natural/predictive autoantibodies. Shovman O, Gilburd B, Barzilai O, Shinar E, Larida B, Zandman-Goddard G, Binder SR, Shoenfeld Y. Ann N Y Acad Sci; 2005 Jun; 1050():380-8. PubMed ID: 16014555 [Abstract] [Full Text] [Related]
3. Multiplexed AtheNA multi-lyte immunoassay for ANA screening in autoimmune diseases. Shovman O, Gilburd B, Zandman-Goddard G, Yehiely A, Langevitz P, Shoenfeld Y. Autoimmunity; 2005 Feb; 38(1):105-9. PubMed ID: 15804711 [Abstract] [Full Text] [Related]
4. Laboratory screening of connective tissue diseases by a new automated ENA screening assay (EliA Symphony) in clinically defined patients. González C, García-Berrocal B, Pérez M, Navajo JA, Herraez O, González-Buitrago JM. Clin Chim Acta; 2005 Sep; 359(1-2):109-14. PubMed ID: 15894301 [Abstract] [Full Text] [Related]
5. Measurement of autoantibodies using multiplex methodology in patients with systemic lupus erythematosus. Hanly JG, Thompson K, McCurdy G, Fougere L, Theriault C, Wilton K. J Immunol Methods; 2010 Jan 31; 352(1-2):147-52. PubMed ID: 19836394 [Abstract] [Full Text] [Related]
6. Cost-effective detection of non-antidouble-stranded DNA antinuclear antibody specificities in daily clinical practice. Vos PA, Bast EJ, Derksen RH. Rheumatology (Oxford); 2006 May 31; 45(5):629-35. PubMed ID: 16368728 [Abstract] [Full Text] [Related]
7. BioPlex 2200 multiplexed system: simultaneous detection of anti-dsDNA and anti-chromatin antibodies in patients with systemic lupus erythematosus. Bardin N, Desplat-Jego S, Daniel L, Jourde Chiche N, Sanmarco M. Autoimmunity; 2009 Jan 31; 42(1):63-8. PubMed ID: 19127456 [Abstract] [Full Text] [Related]
8. Comparison of different test systems for simultaneous autoantibody detection in connective tissue diseases. Eissfeller P, Sticherling M, Scholz D, Hennig K, Lüttich T, Motz M, Kromminga A. Ann N Y Acad Sci; 2005 Jun 31; 1050():327-39. PubMed ID: 16014549 [Abstract] [Full Text] [Related]
9. Evaluation of the LIAISON ANA screen assay for antinuclear antibody testing in autoimmune diseases. Ghillani P, Rouquette AM, Desgruelles C, Hauguel N, Le Pendeven C, Piette JC, Musset L. Ann N Y Acad Sci; 2007 Aug 31; 1109():407-13. PubMed ID: 17785329 [Abstract] [Full Text] [Related]
10. [Evaluation of simultaneous detection of specific antinuclear antibodies using multiplexed technology]. Uto K, Hayashi N, Kinoshita S, Kawano S, Kumagai S. Rinsho Byori; 2009 Oct 31; 57(10):941-53. PubMed ID: 19928490 [Abstract] [Full Text] [Related]
11. Correlation of antinuclear antibody immunofluorescence patterns with immune profile using line immunoassay in the Indian scenario. Sebastian W, Roy A, Kini U, Mullick S. Indian J Pathol Microbiol; 2010 Oct 31; 53(3):427-32. PubMed ID: 20699497 [Abstract] [Full Text] [Related]
12. Efficiency of different strategies to detect autoantibodies to extractable nuclear antigens. Almeida González D, Cabrera de León A, Rodríguez Pérez Mdel C, Brito Díaz B, González Hernández A, García García D, Vázquez Moncholi C, Aguirre Jaime A. J Immunol Methods; 2010 Aug 31; 360(1-2):89-95. PubMed ID: 20600078 [Abstract] [Full Text] [Related]
13. Detection of autoantibodies to nuclear antigens by EIA and IF techniques. Alem M, Moghadam S, Malki J, Zaidi A, Nayak N, Li TM. Allerg Immunol (Paris); 1997 Sep 31; 29(7):188, 191-4. PubMed ID: 9373708 [Abstract] [Full Text] [Related]
14. [Comparison between line immunoassay (LIA) and enzyme-linked immunosorbent assay (ELISA) for the determination of antibodies to extractable nuclear antigenes (ENA) with reference to other laboratory results and clinical features]. Maclachlan D, Vogt P, Wu X, Rose L, Tyndall A, Hasler P. Z Rheumatol; 2002 Oct 31; 61(5):534-44. PubMed ID: 12399881 [Abstract] [Full Text] [Related]
15. Detection and identification of significant ANAs in previously determined ANA negative samples. Kidd K, Cusi K, Mueller R, Goodner M, Boyes B, Hoy E. Clin Lab; 2005 Oct 31; 51(9-10):517-21. PubMed ID: 16285474 [Abstract] [Full Text] [Related]
16. Evaluation of the new multiplexed immunoassay, FIDIS, for simultaneous quantitative determination of antinuclear antibodies and comparison with conventional methods. Rouquette AM, Desgruelles C, Laroche P. Am J Clin Pathol; 2003 Nov 31; 120(5):676-81. PubMed ID: 14608892 [Abstract] [Full Text] [Related]
17. Antinuclear antibody detection by automated multiplex immunoassay in untreated patients at the time of diagnosis. Op De Beéck K, Vermeersch P, Verschueren P, Westhovens R, Mariën G, Blockmans D, Bossuyt X. Autoimmun Rev; 2012 Dec 31; 12(2):137-43. PubMed ID: 22387973 [Abstract] [Full Text] [Related]
18. Detection of antinuclear antibodies: comparative evaluation of enzyme immunoassay and indirect immunofluorescence methods. Homburger HA, Cahen YD, Griffiths J, Jacob GL. Arch Pathol Lab Med; 1998 Nov 31; 122(11):993-9. PubMed ID: 9822128 [Abstract] [Full Text] [Related]
19. Multiplex assessment of non-organ-specific autoantibodies with a novel microbead-based immunoassay. Grossmann K, Roggenbuck D, Schröder C, Conrad K, Schierack P, Sack U. Cytometry A; 2011 Feb 31; 79(2):118-25. PubMed ID: 21265005 [Abstract] [Full Text] [Related]
20. Clinical value of multiplexed bead-based immunoassays for detection of autoantibodies to nuclear antigens. Avaniss-Aghajani E, Berzon S, Sarkissian A. Clin Vaccine Immunol; 2007 May 31; 14(5):505-9. PubMed ID: 17376860 [Abstract] [Full Text] [Related] Page: [Next] [New Search]