These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


390 related items for PubMed ID: 17899755

  • 1. [On the thermal responses of a rectangular AFM cantilever coupled surface by the elastic biological specimens].
    Fang Y, Wu J.
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):829-34. PubMed ID: 17899755
    [Abstract] [Full Text] [Related]

  • 2. Thermo-mechanical responses of a surface-coupled AFM cantilever.
    Wu J, Fang Y, Yang D, Zhu C.
    J Biomech Eng; 2005 Dec; 127(7):1208-15. PubMed ID: 16502663
    [Abstract] [Full Text] [Related]

  • 3. Suppression of spurious vibration of cantilever in atomic force microscopy by enhancement of bending rigidity of cantilever chip substrate.
    Tsuji T, Kobari K, Ide S, Yamanaka K.
    Rev Sci Instrum; 2007 Oct; 78(10):103703. PubMed ID: 17979424
    [Abstract] [Full Text] [Related]

  • 4. Atomic force microscopy (AFM).
    Trache A, Meininger GA.
    Curr Protoc Microbiol; 2008 Feb; Chapter 2():Unit 2C.2. PubMed ID: 18770536
    [Abstract] [Full Text] [Related]

  • 5. Cell dynamic adhesion and elastic properties probed with cylindrical atomic force microscopy cantilever tips.
    Rico F, Roca-Cusachs P, Sunyer R, Farré R, Navajas D.
    J Mol Recognit; 2007 Feb; 20(6):459-66. PubMed ID: 17891755
    [Abstract] [Full Text] [Related]

  • 6. Assessing micromechanical properties of cells with atomic force microscopy: importance of the contact point.
    Crick SL, Yin FC.
    Biomech Model Mechanobiol; 2007 Apr; 6(3):199-210. PubMed ID: 16775736
    [Abstract] [Full Text] [Related]

  • 7. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers.
    Yeh MK, Tai NH, Chen BY.
    Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729
    [Abstract] [Full Text] [Related]

  • 8. Studying the mechanics of cellular processes by atomic force microscopy.
    Radmacher M.
    Methods Cell Biol; 2007 Sep; 83():347-72. PubMed ID: 17613316
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Compact variable-temperature scanning force microscope.
    Chuang TM, de Lozanne A.
    Rev Sci Instrum; 2007 May; 78(5):053710. PubMed ID: 17552828
    [Abstract] [Full Text] [Related]

  • 12. Direct measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter.
    Ying ZC, Reitsma MG, Gates RS.
    Rev Sci Instrum; 2007 Jun; 78(6):063708. PubMed ID: 17614617
    [Abstract] [Full Text] [Related]

  • 13. Nanointerrogation of ultrasonic contrast agent microbubbles using atomic force microscopy.
    Sboros V, Glynos E, Pye SD, Moran CM, Butler M, Ross J, Short R, McDicken WN, Koutsos V.
    Ultrasound Med Biol; 2006 Apr; 32(4):579-85. PubMed ID: 16616603
    [Abstract] [Full Text] [Related]

  • 14. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array.
    Gates RS, Reitsma MG.
    Rev Sci Instrum; 2007 Aug; 78(8):086101. PubMed ID: 17764361
    [Abstract] [Full Text] [Related]

  • 15. Quasi-simultaneous imaging/pulling analysis of single polyprotein molecules by atomic force microscopy.
    Valbuena A, Oroz J, Vera AM, Gimeno A, Gómez-Herrero J, Carrión-Vázquez M.
    Rev Sci Instrum; 2007 Nov; 78(11):113707. PubMed ID: 18052480
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18. Reduction of the damping on an AFM cantilever in fluid by the use of micropillars.
    Kawakami M, Taniguchi Y, Hiratsuka Y, Shimoike M, Smith DA.
    Langmuir; 2010 Jan 19; 26(2):1002-7. PubMed ID: 19785459
    [Abstract] [Full Text] [Related]

  • 19. Viscoelastic properties of single polysaccharide molecules determined by analysis of thermally driven oscillations of an atomic force microscope cantilever.
    Kawakami M, Byrne K, Khatri B, McLeish TC, Radford SE, Smith DA.
    Langmuir; 2004 Oct 12; 20(21):9299-303. PubMed ID: 15461521
    [Abstract] [Full Text] [Related]

  • 20. Constant tip-surface distance with atomic force microscopy via quality factor feedback.
    Fan L, Potter D, Sulchek T.
    Rev Sci Instrum; 2012 Feb 12; 83(2):023706. PubMed ID: 22380098
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 20.