These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1027 related items for PubMed ID: 17905265
1. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld AB. J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265 [Abstract] [Full Text] [Related]
2. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Cannesson M, Attof Y, Rosamel P, Joseph P, Bastien O, Lehot JJ. Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154 [Abstract] [Full Text] [Related]
3. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients. Hofer CK, Button D, Weibel L, Genoni M, Zollinger A. J Cardiothorac Vasc Anesth; 2010 Apr; 24(2):257-64. PubMed ID: 19700349 [Abstract] [Full Text] [Related]
4. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. Lorsomradee S, Lorsomradee S, Cromheecke S, De Hert SG. J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266 [Abstract] [Full Text] [Related]
5. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. Manecke GR, Auger WR. J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472 [Abstract] [Full Text] [Related]
6. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F. Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863 [Abstract] [Full Text] [Related]
8. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. Della Rocca G, Costa MG, Chiarandini P, Bertossi G, Lugano M, Pompei L, Coccia C, Sainz-Barriga M, Pietropaoli P. J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423 [Abstract] [Full Text] [Related]
9. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study. Corley A, Barnett AG, Mullany D, Fraser JF. Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107 [Abstract] [Full Text] [Related]
10. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor. Zimmermann A, Kufner C, Hofbauer S, Steinwendner J, Hitzl W, Fritsch G, Schistek R, Kirnbauer M, Pauser G. J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):388-93. PubMed ID: 18503926 [Abstract] [Full Text] [Related]
11. Validation of a new arterial pulse contour-based cardiac output device. de Waal EE, Kalkman CJ, Rex S, Buhre WF. Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493 [Abstract] [Full Text] [Related]
12. [Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements]. Simon R, Desebbe O, Hénaine R, Bastien O, Lehot JJ, Cannesson M. Ann Fr Anesth Reanim; 2009 Jun; 28(6):537-41. PubMed ID: 19525086 [Abstract] [Full Text] [Related]
13. Continuous cardiac index monitoring: A prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique. McCoy JV, Hollenberg SM, Dellinger RP, Arnold RC, Ruoss L, Lotano V, Peters P, Parrillo JE, Trzeciak S. Resuscitation; 2009 Aug; 80(8):893-7. PubMed ID: 19520480 [Abstract] [Full Text] [Related]
14. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Yamada T, Tsutsui M, Sugo Y, Sato T, Akazawa T, Sato N, Yamashita K, Ishihara H, Takeda J. Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885 [Abstract] [Full Text] [Related]
18. A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Cecconi M, Dawson D, Casaretti R, Grounds RM, Rhodes A. Minerva Anestesiol; 2010 Dec; 76(12):1010-7. PubMed ID: 20634793 [Abstract] [Full Text] [Related]