These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Dosimetric evaluation of conventional radiotherapy, 3-D conformal radiotherapy and direct machine parameter optimisation intensity-modulated radiotherapy for breast cancer after conservative surgery. Zhang F, Zheng M. J Med Imaging Radiat Oncol; 2011 Dec; 55(6):595-602. PubMed ID: 22141607 [Abstract] [Full Text] [Related]
6. Intensity-modulated radiotherapy improves lymph node coverage and dose to critical structures compared with three-dimensional conformal radiation therapy in clinically localized prostate cancer. Wang-Chesebro A, Xia P, Coleman J, Akazawa C, Roach M. Int J Radiat Oncol Biol Phys; 2006 Nov 01; 66(3):654-62. PubMed ID: 17011444 [Abstract] [Full Text] [Related]
7. Dosimetric comparison of three different involved nodal irradiation techniques for stage II Hodgkin's lymphoma patients: conventional radiotherapy, intensity-modulated radiotherapy, and three-dimensional proton radiotherapy. Chera BS, Rodriguez C, Morris CG, Louis D, Yeung D, Li Z, Mendenhall NP. Int J Radiat Oncol Biol Phys; 2009 Nov 15; 75(4):1173-80. PubMed ID: 19386423 [Abstract] [Full Text] [Related]
8. Dosimetric comparison of four different external beam partial breast irradiation techniques: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy. Moon SH, Shin KH, Kim TH, Yoon M, Park S, Lee DH, Kim JW, Kim DW, Park SY, Cho KH. Radiother Oncol; 2009 Jan 15; 90(1):66-73. PubMed ID: 18992950 [Abstract] [Full Text] [Related]
9. Dosimetry and radiobiologic model comparison of IMRT and 3D conformal radiotherapy in treatment of carcinoma of the prostate. Luxton G, Hancock SL, Boyer AL. Int J Radiat Oncol Biol Phys; 2004 May 01; 59(1):267-84. PubMed ID: 15093924 [Abstract] [Full Text] [Related]
10. Dosimetric comparison between 3DCRT and IMRT using different multileaf collimators in the treatment of brain tumors. Ding M, Newman F, Chen C, Stuhr K, Gaspar LE. Med Dosim; 2009 May 01; 34(1):1-8. PubMed ID: 19181248 [Abstract] [Full Text] [Related]
12. Combined photon and electron three-dimensional conformal versus intensity-modulated radiotherapy with integrated boost for adjuvant treatment of malignant pleural mesothelioma after pleuropneumonectomy. Krayenbuehl J, Oertel S, Davis JB, Ciernik IF. Int J Radiat Oncol Biol Phys; 2007 Dec 01; 69(5):1593-9. PubMed ID: 17931793 [Abstract] [Full Text] [Related]
13. Dosimetric comparison between 2-dimensional radiation therapy and intensity modulated radiation therapy in treatment of advanced T-stage nasopharyngeal carcinoma: to treat less or more in the planning organ-at-risk volume of the brainstem and spinal cord. Chau RM, Teo PM, Kam MK, Leung SF, Cheung KY, Chan AT. Med Dosim; 2007 Dec 01; 32(4):263-70. PubMed ID: 17980826 [Abstract] [Full Text] [Related]
14. Helical tomotherapy for radiotherapy in esophageal cancer: a preferred plan with better conformal target coverage and more homogeneous dose distribution. Chen YJ, Liu A, Han C, Tsai PT, Schultheiss TE, Pezner RD, Vora N, Lim D, Shibata S, Kernstine KH, Wong JY. Med Dosim; 2007 Dec 01; 32(3):166-71. PubMed ID: 17707195 [Abstract] [Full Text] [Related]
15. Potential effect of robust and simple IMRT approach for left-sided breast cancer on cardiac mortality. Lohr F, El-Haddad M, Dobler B, Grau R, Wertz HJ, Kraus-Tiefenbacher U, Steil V, Madyan YA, Wenz F. Int J Radiat Oncol Biol Phys; 2009 May 01; 74(1):73-80. PubMed ID: 18973977 [Abstract] [Full Text] [Related]
16. Is intensity-modulated radiotherapy better than conventional radiation treatment and three-dimensional conformal radiotherapy for mediastinal masses in patients with Hodgkin's disease, and is there a role for beam orientation optimization and dose constraints assigned to virtual volumes? Girinsky T, Pichenot C, Beaudre A, Ghalibafian M, Lefkopoulos D. Int J Radiat Oncol Biol Phys; 2006 Jan 01; 64(1):218-26. PubMed ID: 16169675 [Abstract] [Full Text] [Related]
17. Direct aperture optimization-based intensity-modulated radiotherapy for whole breast irradiation. Ahunbay EE, Chen GP, Thatcher S, Jursinic PA, White J, Albano K, Li XA. Int J Radiat Oncol Biol Phys; 2007 Mar 15; 67(4):1248-58. PubMed ID: 17275205 [Abstract] [Full Text] [Related]
18. Improvement in dose homogeneity with electronic tissue compensation over IMRT and conventional RT in whole brain radiotherapy. Goyal S, Yue NJ, Millevoi R, Kagan E, Haffty B, Narra V. Radiother Oncol; 2008 Aug 15; 88(2):196-201. PubMed ID: 18362037 [Abstract] [Full Text] [Related]
19. Improving dose homogeneity in large breasts by IMRT: efficacy and dosimetric accuracy of different techniques. Abo-Madyan Y, Polednik M, Rahn A, Schneider F, Dobler B, Wenz F, Lohr F. Strahlenther Onkol; 2008 Feb 15; 184(2):86-92. PubMed ID: 18259700 [Abstract] [Full Text] [Related]
20. Pilot study of conformal intensity modulated radiation therapy for localized prostate cancer. Aillères N, Azria D, Thézenas S, Barbier N, Fenoglietto P, Delard R, Hay MH, Dubois JB. Cancer Radiother; 2004 Apr 15; 8(2):59-69. PubMed ID: 15063872 [Abstract] [Full Text] [Related] Page: [Next] [New Search]