172 related items for PubMed ID: 18041753
1. An experimental model for the measurement of inspired gas temperatures in ventilated neonates. Jardine LA, Dunster KR, Davies MW. Pediatr Pulmonol; 2008 Jan; 43(1):29-33. PubMed ID: 18041753 [Abstract] [Full Text] [Related]
2. Inspired gas temperature in ventilated neonates. Davies MW, Dunster KR, Cartwright DW. Pediatr Pulmonol; 2004 Jul; 38(1):50-4. PubMed ID: 15170873 [Abstract] [Full Text] [Related]
3. Factors affecting humidity of inspired gas in a neonatal lung model. Rios A, Brion LP, Fleischman AR. J Perinatol; 1998 Jul; 18(1):31-7. PubMed ID: 9527942 [Abstract] [Full Text] [Related]
4. A drop in gas temperature in the external part of the endotracheal tube is problematic during neonatal respiratory support. Yamada Y, Kyuno T, Suzuki S, Ito T, Kato I, Togari H. Pediatr Pulmonol; 2008 Jul; 43(7):666-73. PubMed ID: 18500729 [Abstract] [Full Text] [Related]
5. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings. Hentschel R, Buntzel J, Guttmann J, Schumann S. Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238 [Abstract] [Full Text] [Related]
6. Albuterol delivery by metered-dose inhaler with a pediatric mechanical ventilatory circuit model. Garner SS, Wiest DB, Bradley JW. Pharmacotherapy; 1994 Sep; 14(2):210-4. PubMed ID: 8197041 [Abstract] [Full Text] [Related]
7. Inspired gas humidity during mechanical ventilation: effects of humidification chamber, airway temperature probe position and environmental conditions. Todd DA, Boyd J, Lloyd J, John E. J Paediatr Child Health; 2001 Oct; 37(5):489-94. PubMed ID: 11885715 [Abstract] [Full Text] [Related]
8. Inspired gas temperature during mechanical ventilation: effects of environmental temperature and airway temperature probe position. Todd DA, Boyd J, Lloyd J, John E. J Paediatr Child Health; 2001 Oct; 37(5):495-500. PubMed ID: 11885716 [Abstract] [Full Text] [Related]
9. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate. Ivanov VA. Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200 [Abstract] [Full Text] [Related]
10. Inspired gas humidity and temperature during mechanical ventilation with the Stephanie ventilator. Preo BL, Shadbolt B, Todd DA. Paediatr Anaesth; 2013 Nov; 23(11):1062-8. PubMed ID: 23750698 [Abstract] [Full Text] [Related]
11. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM, Salyer JW, Zignego JC, Redding GJ, Richardson CP. Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [Abstract] [Full Text] [Related]
12. Humidification during high-frequency oscillation ventilation is affected by ventilator circuit and ventilatory setting. Chikata Y, Imanaka H, Onishi Y, Ueta M, Nishimura M. Paediatr Anaesth; 2009 Aug; 19(8):779-83. PubMed ID: 19624365 [Abstract] [Full Text] [Related]
13. Catheters for tracheal gas insufflation. Adams AB. Respir Care; 2001 Feb; 46(2):177-84. PubMed ID: 11175246 [Abstract] [Full Text] [Related]
14. The temperature and humidity in a low-flow anesthesia workstation with and without a heat and moisture exchanger. de Castro J, Bolfi F, de Carvalho LR, Braz JR. Anesth Analg; 2011 Sep; 113(3):534-8. PubMed ID: 21680862 [Abstract] [Full Text] [Related]
15. Effect of heliox on albuterol delivery by metered-dose inhaler in pediatric in vitro models of mechanical ventilation. Garner SS, Wiest DB, Stevens CE, Habib DM. Pharmacotherapy; 2006 Oct; 26(10):1396-402. PubMed ID: 16999649 [Abstract] [Full Text] [Related]
16. Performance of heated wire humidifiers: an in vitro study. Pelosi P, Chiumello D, Severgnini P, De Grandis CE, Landi L, Chierichetti LM, Frigerio A, Munaro M, Park G, Chiaranda M. J Crit Care; 2007 Sep; 22(3):258-64. PubMed ID: 17869979 [Abstract] [Full Text] [Related]
17. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief? Maeda Y, Fujino Y, Uchiyama A, Taenaka N, Mashimo T, Nishimura M. Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975 [Abstract] [Full Text] [Related]
18. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification. Inui D, Oto J, Nishimura M. BMC Pulm Med; 2006 Aug 08; 6():19. PubMed ID: 16895607 [Abstract] [Full Text] [Related]
19. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures. Brown MK, Willms DC. Respir Care; 2005 Mar 08; 50(3):354-60. PubMed ID: 15737245 [Abstract] [Full Text] [Related]
20. The temperature and humidity of inspired gases in infants using a pediatric circle system: effects of high and low-flow anesthesia. Hunter T, Lerman J, Bissonnette B. Paediatr Anaesth; 2005 Sep 08; 15(9):750-4. PubMed ID: 16101705 [Abstract] [Full Text] [Related] Page: [Next] [New Search]