These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
289 related items for PubMed ID: 18091167
1. Effects of surface conditioning on the retentiveness of titanium crowns over short implant abutments. Sadig WM, Al Harbi MW. Implant Dent; 2007 Dec; 16(4):387-96. PubMed ID: 18091167 [Abstract] [Full Text] [Related]
2. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns. Kim Y, Yamashita J, Shotwell JL, Chong KH, Wang HL. J Prosthet Dent; 2006 Jun; 95(6):450-5. PubMed ID: 16765158 [Abstract] [Full Text] [Related]
3. Retentiveness of dental cements used with metallic implant components. Squier RS, Agar JR, Duncan JP, Taylor TD. Int J Oral Maxillofac Implants; 2001 Jun; 16(6):793-8. PubMed ID: 11769829 [Abstract] [Full Text] [Related]
13. Retention of zirconia ceramic copings bonded to titanium abutments. Ebert A, Hedderich J, Kern M. Int J Oral Maxillofac Implants; 2007 Feb; 22(6):921-7. PubMed ID: 18271373 [Abstract] [Full Text] [Related]
14. Fracture resistance and failure location of zirconium and metallic implant abutments. Aramouni P, Zebouni E, Tashkandi E, Dib S, Salameh Z, Almas K. J Contemp Dent Pract; 2008 Nov 01; 9(7):41-8. PubMed ID: 18997915 [Abstract] [Full Text] [Related]
15. Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration. Pan YH, Ramp LC, Lin CK, Liu PR. Int J Oral Maxillofac Implants; 2006 Nov 01; 21(4):587-92. PubMed ID: 16955610 [Abstract] [Full Text] [Related]
16. Influence of abutment height and surface roughness on in vitro retention of three luting agents. Cano-Batalla J, Soliva-Garriga J, Campillo-Funollet M, Munoz-Viveros CA, Giner-Tarrida L. Int J Oral Maxillofac Implants; 2012 Nov 01; 27(1):36-41. PubMed ID: 22299076 [Abstract] [Full Text] [Related]
19. The effect of luting agents on the retention of dental implant-supported crowns. Pan YH, Lin CK. Chang Gung Med J; 2005 Jun 01; 28(6):403-10. PubMed ID: 16124156 [Abstract] [Full Text] [Related]
20. Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments. Keith SE, Miller BH, Woody RD, Higginbottom FL. Int J Oral Maxillofac Implants; 1999 Jun 01; 14(3):369-78. PubMed ID: 10379110 [Abstract] [Full Text] [Related] Page: [Next] [New Search]