These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
320 related items for PubMed ID: 1819236
1. [Development of artificial blood vessel suitable for cerebrovascular surgery: improvement in the mechanical properties]. Miyamoto S. Nihon Geka Hokan; 1991 Jan 01; 60(1):25-37. PubMed ID: 1819236 [Abstract] [Full Text] [Related]
3. [Test of carotid artery replacement by polyurethane artificial vascular graft with recombinant fibrinolytic enzyme factor II-modified lumina in dogs]. Pan S, Yin S, Yao J, Zheng H, Yi W, Dai G. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jul 01; 22(7):832-7. PubMed ID: 18681285 [Abstract] [Full Text] [Related]
9. Tissue-engineered blood vessel graft produced by self-derived cells and allogenic acellular matrix: a functional performance and histologic study. Yang D, Guo T, Nie C, Morris SF. Ann Plast Surg; 2009 Mar 01; 62(3):297-303. PubMed ID: 19240529 [Abstract] [Full Text] [Related]
13. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model. Wilson GJ, MacGregor DC, Klement P, Weber BA, Binnington AG, Pinchuk L. ASAIO J; 1993 Mar 01; 39(3):M526-31. PubMed ID: 8268591 [Abstract] [Full Text] [Related]
14. Small-caliber polyurethane and polytetrafluoroethylene grafts: a comparative study in a canine aortoiliac model. Brothers TE, Stanley JC, Burkel WE, Graham LM. J Biomed Mater Res; 1990 Jun 01; 24(6):761-71. PubMed ID: 2361967 [Abstract] [Full Text] [Related]
15. [Effect of preparation conditions for small-diameter artificial polyurethane vascular graft on microstructure and mechanical properties]. Pan S, Yang S, Yi W, Zheng H, Tao J. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2005 Jan 01; 19(1):64-9. PubMed ID: 15704848 [Abstract] [Full Text] [Related]
16. Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation. Sonoda H, Takamizawa K, Nakayama Y, Yasui H, Matsuda T. J Biomed Mater Res A; 2003 May 01; 65(2):170-81. PubMed ID: 12734809 [Abstract] [Full Text] [Related]
17. Newly designed compliant hierarchic hybrid vascular graft wrapped with microprocessed elastomeric film--II: Morphogenesis and compliance change upon implantation. He H, Matsuda T. Cell Transplant; 2002 May 01; 11(1):75-87. PubMed ID: 12095223 [Abstract] [Full Text] [Related]
18. The effect of wall mechanical properties on patency of arterial grafts. Kidson IG. Ann R Coll Surg Engl; 1983 Jan 01; 65(1):24-9. PubMed ID: 6218775 [Abstract] [Full Text] [Related]