These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
248 related items for PubMed ID: 18307394
1. Er:YAG Laser, ultrasonic system, and curette produce different profiles on dentine root surfaces: an in vitro study. de Mendonça AC, Máximo MB, Rodrigues JA, Arrais CA, de Freitas PM, Duarte PM. Photomed Laser Surg; 2008 Apr; 26(2):91-7. PubMed ID: 18307394 [Abstract] [Full Text] [Related]
2. In vitro adhesion of Streptococcus sanguinis to dentine root surface after treatment with Er:YAG laser, ultrasonic system, or manual curette. Ota-Tsuzuki C, Martins FL, Giorgetti AP, de Freitas PM, Duarte PM. Photomed Laser Surg; 2009 Oct; 27(5):735-41. PubMed ID: 19712018 [Abstract] [Full Text] [Related]
3. Profilometric Analysis of Periodontally Diseased Root Surfaces After Application of Different Instrumentation Tools: An In Vitro Study. Gürsoy H, Tunar OL, Ince Kuka G, Ozkan Karaca E, Kocabaş H, Kuru BE. Photobiomodul Photomed Laser Surg; 2020 Mar; 38(3):181-185. PubMed ID: 31944884 [Abstract] [Full Text] [Related]
4. Effects of root surface debridement using Er:YAG laser versus ultrasonic scaling - a SEM study. Miremadi SR, Cosyn J, Schaubroeck D, Lang NP, De Moor RJ, De Bruyn H. Int J Dent Hyg; 2014 Nov; 12(4):273-84. PubMed ID: 24871380 [Abstract] [Full Text] [Related]
5. Evaluation of the effects of Er:YAG and Nd:YAG lasers and ultrasonic instrumentation on root surfaces. Gómez C, Bisheimer M, Costela A, García-Moreno I, García A, García JA. Photomed Laser Surg; 2009 Feb; 27(1):43-8. PubMed ID: 19196104 [Abstract] [Full Text] [Related]
6. Effect of instrumentation using curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser on the morphology and adhesion of blood components on root surfaces: a SEM study. Tsurumaki Jdo N, Souto BH, Oliveira GJ, Sampaio JE, Marcantonio Júnior E, Marcantonio RA. Braz Dent J; 2011 Feb; 22(3):185-92. PubMed ID: 21915514 [Abstract] [Full Text] [Related]
7. Morphological assessment of dentine and cementum following apicectomy with Zekrya burs and Er:YAG laser associated with direct and indirect Nd:YAG laser irradiation. de Moura AA, Moura-Netto C, Barletta FB, Vieira-Júnior ND, Eduardo Cde P. Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Apr; 109(4):e77-82. PubMed ID: 20303051 [Abstract] [Full Text] [Related]
8. Evaluation of root surface microtopography following the use of four instrumentation systems by confocal microscopy and scanning electron microscopy: an in vitro study. Solís Moreno C, Santos A, Nart J, Levi P, Velásquez A, Sanz Moliner J. J Periodontal Res; 2012 Oct; 47(5):608-15. PubMed ID: 22494068 [Abstract] [Full Text] [Related]
9. A Comparative Evaluation of Root Surface Biomodification with Erbium-Doped Yttrium Aluminum Garnet Laser, Ethylenediaminetetraacetic Acid Gel, and Titanium Nitride Curette: In Vitro Scanning Electron Microscope and Profilometry Analyses. Tunar OL, Gursoy H, Ozkan Karaca E, Kuru BE. Photobiomodul Photomed Laser Surg; 2021 Dec; 39(12):766-773. PubMed ID: 34878931 [Abstract] [Full Text] [Related]
10. Effect of two kinds of Er:YAG laser systems on root surface in comparison to ultrasonic scaling: an in vitro study. Herrero A, García-Kass AI, Gómez C, Sanz M, García-Nuñez JA. Photomed Laser Surg; 2010 Aug; 28(4):497-504. PubMed ID: 19860568 [Abstract] [Full Text] [Related]
11. Effects of irradiation of an erbium:YAG laser on root surfaces. Yamaguchi H, Kobayashi K, Osada R, Sakuraba E, Nomura T, Arai T, Nakamura J. J Periodontol; 1997 Dec; 68(12):1151-5. PubMed ID: 9444588 [Abstract] [Full Text] [Related]
12. Effects of Nd:YAG laser radiation on removal of a root surface smear layer after root planing: a scanning electron microscopic study. Ito K, Nishikata J, Murai S. J Periodontol; 1993 Jun; 64(6):547-52. PubMed ID: 8336255 [Abstract] [Full Text] [Related]
13. Scanning electron microscopic evaluation of enamel and dentin surfaces after Er:YAG laser preparation and laser conditioning. Delmé KI, De Moor RJ. Photomed Laser Surg; 2007 Oct; 25(5):393-401. PubMed ID: 17975952 [Abstract] [Full Text] [Related]
14. Tooth substance loss resulting from mechanical, sonic and ultrasonic root instrumentation assessed by liquid scintillation. Schmidlin PR, Beuchat M, Busslinger A, Lehmann B, Lutz F. J Clin Periodontol; 2001 Nov; 28(11):1058-66. PubMed ID: 11686828 [Abstract] [Full Text] [Related]
15. Root surface removal and resultant surface texture with diamond-coated ultrasonic inserts: an in vitro and SEM study. Vastardis S, Yukna RA, Rice DA, Mercante D. J Clin Periodontol; 2005 May; 32(5):467-73. PubMed ID: 15842261 [Abstract] [Full Text] [Related]
16. Effects of dentin surface modifications treated with Er:YAG and Nd:YAG laser irradiation on fibroblast cell adhesion. Bolortuya G, Ebihara A, Ichinose S, Watanabe S, Anjo T, Kokuzawa C, Saegusa H, Kawashima N, Suda H. Photomed Laser Surg; 2012 Feb; 30(2):63-70. PubMed ID: 22107609 [Abstract] [Full Text] [Related]
17. A microscopic analysis of the effects of root surface scaling with different power parameters of Er,Cr:YSGG laser. de Oliveira GJ, Cominotte MA, Beraldo TP, Sampaio JE, Marcantonio RA. Microsc Res Tech; 2015 Jun; 78(6):529-35. PubMed ID: 25951453 [Abstract] [Full Text] [Related]
18. Histological and SEM analysis of root cementum following irradiation with Er:YAG and CO2 lasers. Almehdi A, Aoki A, Ichinose S, Taniguchi Y, Sasaki KM, Ejiri K, Sawabe M, Chui C, Katagiri S, Izumi Y. Lasers Med Sci; 2013 Jan; 28(1):203-13. PubMed ID: 22580557 [Abstract] [Full Text] [Related]
19. Root surface roughness evaluation following application of different periodontal instruments and Er:YAG laser: A profilometry and SEM study. İnce Kuka G, Gürsoy H. Lasers Med Sci; 2024 Apr 07; 39(1):98. PubMed ID: 38583109 [Abstract] [Full Text] [Related]
20. In vitro studies of the ablation mechanism of periodontopathic bacteria and decontamination effect on periodontally diseased root surfaces by erbium:yttrium-aluminum-garnet laser. Akiyama F, Aoki A, Miura-Uchiyama M, Sasaki KM, Ichinose S, Umeda M, Ishikawa I, Izumi Y. Lasers Med Sci; 2011 Mar 07; 26(2):193-204. PubMed ID: 20309597 [Abstract] [Full Text] [Related] Page: [Next] [New Search]