These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
262 related items for PubMed ID: 18348214
1. An improved pixel-based approach for analyzing images in two-dimensional gel electrophoresis. Rye MB, Faergestad EM, Martens H, Wold JP, Alsberg BK. Electrophoresis; 2008 Mar; 29(6):1382-93. PubMed ID: 18348214 [Abstract] [Full Text] [Related]
2. A new method for assigning common spot boundaries for multiple gels in two-dimensional gel electrophoresis. Rye MB, Faergestad EM, Alsberg BK. Electrophoresis; 2008 Mar; 29(6):1359-68. PubMed ID: 18348212 [Abstract] [Full Text] [Related]
3. Pixel-based analysis of multiple images for the identification of changes: a novel approach applied to unravel proteome patterns [corrected] of 2-D electrophoresis gel images. Faergestad EM, Rye M, Walczak B, Gidskehaug L, Wold JP, Grove H, Jia X, Hollung K, Indahl UG, Westad F, van den Berg F, Martens H. Proteomics; 2007 Oct; 7(19):3450-61. PubMed ID: 17726676 [Abstract] [Full Text] [Related]
4. A multivariate spot filtering model for two-dimensional gel electrophoresis. Rye MB, Alsberg BK. Electrophoresis; 2008 Mar; 29(6):1369-81. PubMed ID: 18348213 [Abstract] [Full Text] [Related]
5. Quantitative comparison and evaluation of two commercially available, two-dimensional electrophoresis image analysis software packages, Z3 and Melanie. Raman B, Cheung A, Marten MR. Electrophoresis; 2002 Jul; 23(14):2194-202. PubMed ID: 12210223 [Abstract] [Full Text] [Related]
6. The inter- and intra-operator variability in manual spot segmentation and its effect on spot quantitation in two-dimensional electrophoresis analysis. Millioni R, Sbrignadello S, Tura A, Iori E, Murphy E, Tessari P. Electrophoresis; 2010 May; 31(10):1739-42. PubMed ID: 20408132 [Abstract] [Full Text] [Related]
8. A review of the CLIP system for the quantitative analysis of two-dimensional electrophoresis gels. Potter DJ. Electrophoresis; 1990 May; 11(5):415-9. PubMed ID: 2364927 [Abstract] [Full Text] [Related]
9. Explorative data analysis of two-dimensional electrophoresis gels. Schultz J, Gottlieb DM, Petersen M, Nesic L, Jacobsen S, Søndergaard I. Electrophoresis; 2004 Feb; 25(3):502-11. PubMed ID: 14760644 [Abstract] [Full Text] [Related]
12. Improved dynamic range of protein quantification in silver-stained gels by modelling gel images over time. Grove H, Faergestad EM, Hollung K, Martens H. Electrophoresis; 2009 Jun; 30(11):1856-62. PubMed ID: 19517441 [Abstract] [Full Text] [Related]
13. Measurement of specific radioactivity in proteins separated by two-dimensional gel electrophoresis. Zhou S, Mann CJ, Dunn MJ, Preedy VR, Emery PW. Electrophoresis; 2006 Mar; 27(5-6):1147-53. PubMed ID: 16470777 [Abstract] [Full Text] [Related]
15. An alternative approach to deal with geometric uncertainties in computer analysis of two-dimensional electrophoresis gels. Kriegel K, Seefeldt I, Hoffmann F, Schultz C, Wenk C, Regitz-Zagrosek V, Oswald H, Fleck E. Electrophoresis; 2000 Jul; 21(13):2637-40. PubMed ID: 10949140 [Abstract] [Full Text] [Related]
16. Challenges related to analysis of protein spot volumes from two-dimensional gel electrophoresis as revealed by replicate gels. Grove H, Hollung K, Uhlen AK, Martens H, Faergestad EM. J Proteome Res; 2006 Dec; 5(12):3399-410. PubMed ID: 17137341 [Abstract] [Full Text] [Related]
18. An image analysis suite for spot detection and spot matching in two-dimensional electrophoresis gels. Srinark T, Kambhamettu C. Electrophoresis; 2008 Feb; 29(3):706-15. PubMed ID: 18203251 [Abstract] [Full Text] [Related]
19. Warping two-dimensional electrophoresis gel images to correct for geometric distortions of the spot pattern. Gustafsson JS, Blomberg A, Rudemo M. Electrophoresis; 2002 Jun; 23(11):1731-44. PubMed ID: 12179995 [Abstract] [Full Text] [Related]