These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
336 related items for PubMed ID: 18356038
1. Quantum dots-bienzyme hybrid system for the sensitive determination of glucose. Yuan J, Guo W, Wang E. Biosens Bioelectron; 2008 May 15; 23(10):1567-71. PubMed ID: 18356038 [Abstract] [Full Text] [Related]
3. A bienzyme channeling glucose sensor with a wide concentration range based on co-entrapment of enzymes in SBA-15 mesopores. Dai Z, Bao J, Yang X, Ju H. Biosens Bioelectron; 2008 Feb 28; 23(7):1070-6. PubMed ID: 18054830 [Abstract] [Full Text] [Related]
4. Bienzyme HRP-GOx-modified gold nanoelectrodes for the sensitive amperometric detection of glucose at low overpotentials. Delvaux M, Walcarius A, Demoustier-Champagne S. Biosens Bioelectron; 2005 Feb 15; 20(8):1587-94. PubMed ID: 15626613 [Abstract] [Full Text] [Related]
5. Chemiluminescence flow biosensor for glucose based on gold nanoparticle-enhanced activities of glucose oxidase and horseradish peroxidase. Lan D, Li B, Zhang Z. Biosens Bioelectron; 2008 Dec 01; 24(4):940-4. PubMed ID: 18783937 [Abstract] [Full Text] [Related]
9. Quantum dot enhancement of bacteriorhodopsin-based electrodes. Griep MH, Walczak KA, Winder EM, Lueking DR, Friedrich CR. Biosens Bioelectron; 2010 Feb 15; 25(6):1493-7. PubMed ID: 19954962 [Abstract] [Full Text] [Related]
10. Magnetic bead-based DNA detection with multi-layers quantum dots labeling for rapid detection of Escherichia coli O157:H7. Liu YJ, Yao DJ, Chang HY, Liu CM, Chen C. Biosens Bioelectron; 2008 Dec 01; 24(4):558-65. PubMed ID: 18644710 [Abstract] [Full Text] [Related]
11. A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase. Sanz V, de Marcos S, Galbán J. Biosens Bioelectron; 2007 Jan 15; 22(6):956-64. PubMed ID: 16750620 [Abstract] [Full Text] [Related]
12. Pd nanoparticle assemblies--as the substitute of HRP, in their biosensing applications for H2O2 and glucose. Han M, Liu S, Bao J, Dai Z. Biosens Bioelectron; 2012 Jan 15; 31(1):151-6. PubMed ID: 22100764 [Abstract] [Full Text] [Related]
13. Graphene quantum dots as a new substrate for immobilization and direct electrochemistry of glucose oxidase: application to sensitive glucose determination. Razmi H, Mohammad-Rezaei R. Biosens Bioelectron; 2013 Mar 15; 41():498-504. PubMed ID: 23098855 [Abstract] [Full Text] [Related]
14. An enhanced glucose biosensor using charge transfer techniques. Lee SR, Sawada K, Takao H, Ishida M. Biosens Bioelectron; 2008 Dec 01; 24(4):650-6. PubMed ID: 18640027 [Abstract] [Full Text] [Related]
15. A simple strategy for one-step construction of bienzyme biosensor by in-situ formation of biocomposite film through electrodeposition. Li F, Wang Z, Chen W, Zhang S. Biosens Bioelectron; 2009 Jun 15; 24(10):3030-5. PubMed ID: 19395252 [Abstract] [Full Text] [Related]
16. Microfluidic bioassay system based on microarrays of hydrogel sensing elements entrapping quantum dot-enzyme conjugates. Jang E, Kim S, Koh WG. Biosens Bioelectron; 2012 Jan 15; 31(1):529-36. PubMed ID: 22177543 [Abstract] [Full Text] [Related]
17. Enzyme biosensor based on NAD-sensitive quantum dots. Ren X, Yang L, Tang F, Yan C, Ren J. Biosens Bioelectron; 2010 Sep 15; 26(1):271-4. PubMed ID: 20627509 [Abstract] [Full Text] [Related]
18. A new route to the considerable enhancement of glucose oxidase (GOx) activity: the simple assembly of a complex from CdTe quantum dots and GOx, and its glucose sensing. Cao L, Ye J, Tong L, Tang B. Chemistry; 2008 Sep 15; 14(31):9633-40. PubMed ID: 18792902 [Abstract] [Full Text] [Related]
19. A glucose biosensor based on Prussian blue/chitosan hybrid film. Wang X, Gu H, Yin F, Tu Y. Biosens Bioelectron; 2009 Jan 01; 24(5):1527-30. PubMed ID: 19010659 [Abstract] [Full Text] [Related]