These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


386 related items for PubMed ID: 18371059

  • 1. Influence of temperature and time before centrifugation of specimens for routine coagulation testing.
    Salvagno GL, Lippi G, Montagnana M, Franchini M, Poli G, Guidi GC.
    Int J Lab Hematol; 2009 Aug; 31(4):462-7. PubMed ID: 18371059
    [Abstract] [Full Text] [Related]

  • 2. Influence of the centrifuge time of primary plasma tubes on routine coagulation testing.
    Lippi G, Salvagno GL, Montagnana M, Manzato F, Guidi GC.
    Blood Coagul Fibrinolysis; 2007 Jul; 18(5):525-8. PubMed ID: 17581331
    [Abstract] [Full Text] [Related]

  • 3. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?
    Rimac V, Coen Herak D.
    Int J Lab Hematol; 2017 Oct; 39(5):475-481. PubMed ID: 28488785
    [Abstract] [Full Text] [Related]

  • 4. Effect of freezing method and storage at -20 degrees C and -70 degrees C on prothrombin time, aPTT and plasma fibrinogen levels.
    Alesci S, Borggrefe M, Dempfle CE.
    Thromb Res; 2009 May; 124(1):121-6. PubMed ID: 19128820
    [Abstract] [Full Text] [Related]

  • 5. Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimer.
    Kemkes-Matthes B, Fischer R, Peetz D.
    Blood Coagul Fibrinolysis; 2011 Apr; 22(3):215-20. PubMed ID: 21297453
    [Abstract] [Full Text] [Related]

  • 6. Influence of Preanalytical Variables on Prothrombin Time, Activated Partial Thromboplastin Time, and Fibrinogen.
    Kim H, Kim Y, Lee HK.
    Clin Lab; 2015 Apr; 61(9):1337-40. PubMed ID: 26554255
    [Abstract] [Full Text] [Related]

  • 7. Effects of storage and thawing conditions on coagulation testing.
    Gosselin RC, Honeychurch K, Kang HJ, Dwyre DM.
    Int J Lab Hematol; 2015 Aug; 37(4):551-9. PubMed ID: 25766006
    [Abstract] [Full Text] [Related]

  • 8. Effect of freezing plasma at -20°C for 2 weeks on prothrombin time, activated partial thromboplastin time, dilute Russell viper venom time, activated protein C resistance, and D-dimer levels.
    Foshat M, Bates S, Russo W, Huerta A, Albright K, Giddings K, Indrikovs A, Qian YW.
    Clin Appl Thromb Hemost; 2015 Jan; 21(1):41-7. PubMed ID: 24842886
    [Abstract] [Full Text] [Related]

  • 9. Influence of temperature and storage duration on measurement of activated partial thromboplastin time, D-dimers, fibrinogen, prothrombin time and thrombin time, in citrate-anticoagulated whole blood specimens.
    Zhao Y, Lv G.
    Int J Lab Hematol; 2013 Oct; 35(5):566-70. PubMed ID: 23718185
    [Abstract] [Full Text] [Related]

  • 10. Coagulation parameters of thawed fresh-frozen plasma during storage at different temperatures.
    Lamboo M, Poland DC, Eikenboom JC, Harvey MS, Groot E, Brand A, de Vries RR.
    Transfus Med; 2007 Jun; 17(3):182-6. PubMed ID: 17561859
    [Abstract] [Full Text] [Related]

  • 11. Monitoring heparin therapy by the activated partial thromboplastin time--the effect of pre-analytical conditions.
    van den Besselaar AM, Meeuwisse-Braun J, Jansen-Grüter R, Bertina RM.
    Thromb Haemost; 1987 Apr 07; 57(2):226-31. PubMed ID: 3603414
    [Abstract] [Full Text] [Related]

  • 12. Modifications of coagulation and fibrinolytic parameters in laparoscopic cholecystectomy.
    Vecchio R, Cacciola E, Martino M, Cacciola RR, MacFadyen BV.
    Surg Endosc; 2003 Mar 07; 17(3):428-33. PubMed ID: 12457211
    [Abstract] [Full Text] [Related]

  • 13. Impact of different storage times at room temperature of unspun citrated blood samples on routine coagulation tests results. Results of a bicenter study and review of the literature.
    Toulon P, Metge S, Hangard M, Zwahlen S, Piaulenne S, Besson V.
    Int J Lab Hematol; 2017 Oct 07; 39(5):458-468. PubMed ID: 28481034
    [Abstract] [Full Text] [Related]

  • 14. Problems with assays based on fibrin clot formation principle: analysis of multilaboratory data.
    Hirai N, Tatsumi N, Hino M, Yamane T, Ohta K.
    Osaka City Med J; 1998 Jun 07; 44(1):55-71. PubMed ID: 9834619
    [Abstract] [Full Text] [Related]

  • 15. Measurement of prothrombin time (PT) and activated partial thromboplastin time (APTT) on canine citrated plasma samples following different storage conditions.
    Rizzo F, Papasouliotis K, Crawford E, Dodkin S, Cue S.
    Res Vet Sci; 2008 Aug 07; 85(1):166-70. PubMed ID: 17998140
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Optimization of the storage conditions for coagulation screening tests.
    Mohammed Saghir SA, Al-Hassan FM, Alsalahi OS, Abdul Manaf FS, Baqir HS.
    J Coll Physicians Surg Pak; 2012 May 07; 22(5):294-7. PubMed ID: 22538033
    [Abstract] [Full Text] [Related]

  • 18. Determining the effect of storage conditions on prothrombin time, activated partial thromboplastin time and fibrinogen concentration in rat plasma samples.
    Goyal VK, Kakade S, Pandey SK, Gothi AK, Nirogi R.
    Lab Anim; 2015 Oct 07; 49(4):311-8. PubMed ID: 26206586
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of a bench-top coagulation analyzer for measurement of prothrombin time, activated partial thromboplastin time, and fibrinogen concentrations in healthy dogs.
    Mineo HK, Garabed RB.
    Am J Vet Res; 2007 Dec 07; 68(12):1342-7. PubMed ID: 18052739
    [Abstract] [Full Text] [Related]

  • 20. [Rapid centrifugation for routine coagulation testing].
    Boudaoud L, Divaret G, Marie P, Bezeaud A.
    Ann Biol Clin (Paris); 2006 Dec 07; 64(4):315-7. PubMed ID: 16829473
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 20.