These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
882 related items for PubMed ID: 18417426
61. Voltammetric peak separation of dopamine from uric acid in the presence of ascorbic acid at greater than ambient solution temperatures. Zen JM, Hsu CT, Hsu YL, Sue JW, Conte ED. Anal Chem; 2004 Jul 15; 76(14):4251-5. PubMed ID: 15253672 [Abstract] [Full Text] [Related]
62. Ion-exchange voltammetry of dopamine at Nafion-coated glassy carbon electrodes: quantitative features of ion-exchange partition and reassessment on the oxidation mechanism of dopamine in the presence of excess ascorbic acid. Rocha LS, Carapuça HM. Bioelectrochemistry; 2006 Oct 15; 69(2):258-66. PubMed ID: 16713377 [Abstract] [Full Text] [Related]
63. ZnO-CuxO/polypyrrole nanocomposite modified electrode for simultaneous determination of ascorbic acid, dopamine, and uric acid. Ghanbari Kh, Hajheidari N. Anal Biochem; 2015 Mar 15; 473():53-62. PubMed ID: 25576954 [Abstract] [Full Text] [Related]
64. Electropolymerisation of L-arginine at carbon paste electrode and its application to the detection of dopamine, ascorbic and uric acid. Chandrashekar BN, Swamy BE, Pandurangachar M, Sathisha TV, Sherigara BS. Colloids Surf B Biointerfaces; 2011 Nov 01; 88(1):413-8. PubMed ID: 21816583 [Abstract] [Full Text] [Related]
65. Simultaneous determination of L-cysteine and L-tyrosine using Au-nanoparticles/poly-eriochrome black T film modified glassy carbon electrode. Liu X, Luo L, Ding Y, Kang Z, Ye D. Bioelectrochemistry; 2012 Aug 01; 86():38-45. PubMed ID: 22360849 [Abstract] [Full Text] [Related]
66. [Selective determination of norepinephrine by a cyclic voltammetric method using poly-proline-modified electrodes]. Ma XY, Chao Z. Nan Fang Yi Ke Da Xue Xue Bao; 2008 Aug 01; 28(8):1454-7. PubMed ID: 18753086 [Abstract] [Full Text] [Related]
67. Sensitive determination of dopamine and uric acid by the use of a glassy carbon electrode modified with poly(3-methylthiophene)/gold nanoparticle composites. Huang X, Li Y, Wang P, Wang L. Anal Sci; 2008 Dec 01; 24(12):1563-8. PubMed ID: 19075465 [Abstract] [Full Text] [Related]
68. Enhanced sensing of dopamine in the present of ascorbic acid based on graphene/poly(p-aminobenzoic acid) composite film. Huang KJ, Jing QS, Wu ZW, Wang L, Wei CY. Colloids Surf B Biointerfaces; 2011 Nov 01; 88(1):310-4. PubMed ID: 21798724 [Abstract] [Full Text] [Related]
69. Electrochemical determination of uric acid at ordered mesoporous carbon functionalized with ferrocenecarboxylic acid-modified electrode. Ndamanisha JC, Guo L. Biosens Bioelectron; 2008 Jun 15; 23(11):1680-5. PubMed ID: 18339534 [Abstract] [Full Text] [Related]
73. Multi-walled carbon nanotube/poly(glycine) modified carbon paste electrode for the determination of dopamine in biological fluids and pharmaceuticals. Thomas T, Mascarenhas RJ, Swamy BE, Martis P, Mekhalif Z, Sherigara BS. Colloids Surf B Biointerfaces; 2013 Oct 01; 110():458-65. PubMed ID: 23770784 [Abstract] [Full Text] [Related]
75. Electrodeposited reduced graphene oxide incorporating polymerization of l-lysine on electrode surface and its application in simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid. Zhang D, Li L, Ma W, Chen X, Zhang Y. Mater Sci Eng C Mater Biol Appl; 2017 Jan 01; 70(Pt 1):241-249. PubMed ID: 27770887 [Abstract] [Full Text] [Related]
76. Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on graphene anchored with Pd-Pt nanoparticles. Yan J, Liu S, Zhang Z, He G, Zhou P, Liang H, Tian L, Zhou X, Jiang H. Colloids Surf B Biointerfaces; 2013 Nov 01; 111():392-7. PubMed ID: 23850748 [Abstract] [Full Text] [Related]
77. Simultaneous voltammetric detection of dopamine and uric acid at their physiological level in the presence of ascorbic acid using poly(acrylic acid)-multiwalled carbon-nanotube composite-covered glassy-carbon electrode. Liu A, Honma I, Zhou H. Biosens Bioelectron; 2007 Aug 30; 23(1):74-80. PubMed ID: 17467972 [Abstract] [Full Text] [Related]
78. Simultaneous determination of dopamine and uric acid using layer-by-layer graphene and chitosan assembled multilayer films. Weng X, Cao Q, Liang L, Chen J, You C, Ruan Y, Lin H, Wu L. Talanta; 2013 Dec 15; 117():359-65. PubMed ID: 24209353 [Abstract] [Full Text] [Related]
79. p-Aminophenol-multiwall carbon nanotubes-TiO2 electrode as a sensor for simultaneous determination of penicillamine and uric acid. Ensafi AA, Khoddami E, Rezaei B, Karimi-Maleh H. Colloids Surf B Biointerfaces; 2010 Nov 01; 81(1):42-9. PubMed ID: 20655185 [Abstract] [Full Text] [Related]
80. Au-nanoclusters incorporated 3-amino-5-mercapto-1,2,4-triazole film modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid and nitrite. Wang C, Yuan R, Chai Y, Zhang Y, Hu F, Zhang M. Biosens Bioelectron; 2011 Dec 15; 30(1):315-9. PubMed ID: 21982642 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]