These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Husebye EE, Lyberg T, Madsen JE, Eriksen M, Røise O. Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266 [Abstract] [Full Text] [Related]
3. A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA). Goplen G, Wilson JA, McAffrey M, Deluzio K, Leighton R. Injury; 2010 Nov; 41 Suppl 2():S38-42. PubMed ID: 21144925 [Abstract] [Full Text] [Related]
4. The physiologic and pathologic effects of the reamer irrigator aspirator on fat embolism outcome: an animal study. Wang RY, Li R, Zdero R, Bell D, Blankstein M, Schemitsch EH. J Orthop Trauma; 2012 Sep; 26(9):e132-7. PubMed ID: 22377507 [Abstract] [Full Text] [Related]
5. Clinical experience of the use of reamer irrigator aspirator in Japanese patients: A report of the first 42 cases. Niikura T, Oe K, Fukui T, Hayashi S, Matsumoto T, Matsushita T, Kuroda R. J Orthop Sci; 2021 May; 26(3):459-465. PubMed ID: 32493622 [Abstract] [Full Text] [Related]
6. Surgical techniques: how I do it? The Reamer/Irrigator/Aspirator (RIA) system. Giannoudis PV, Tzioupis C, Green J. Injury; 2009 Nov; 40(11):1231-6. PubMed ID: 19783249 [Abstract] [Full Text] [Related]
7. Prospective Randomized Clinical Trial Investigating the Effect of the Reamer-Irrigator-Aspirator on the Volume of Embolic Load and Respiratory Function During Intramedullary Nailing of Femoral Shaft Fractures. Hall JA, McKee MD, Vicente MR, Morison ZA, Dehghan N, Schemitsch CE, Kreder HJ, Petrisor B, Schemitsch EH. J Orthop Trauma; 2017 Apr; 31(4):200-204. PubMed ID: 28323763 [Abstract] [Full Text] [Related]
12. Use of the reamer-irrigator-aspirator may reduce tumor dissemination during intramedullary fixation of malignancies. Cipriano CA, Arvanitis LD, Virkus WW. Orthopedics; 2012 Jan 16; 35(1):e48-52. PubMed ID: 22229613 [Abstract] [Full Text] [Related]
13. Safety and efficacy of a novel retrograde route for femoral bone graft harvesting by Reamer-Irrigator-Aspirator: a pilot study on 24 patients. Bidolegui F, Pereira S, Irigoyen C, Pires RE. Patient Saf Surg; 2022 Jan 07; 16(1):2. PubMed ID: 34996503 [Abstract] [Full Text] [Related]
20. Donor site morbidity with reamer-irrigator-aspirator (RIA) use for autogenous bone graft harvesting in a single centre 204 case series. Qvick LM, Ritter CA, Mutty CE, Rohrbacher BJ, Buyea CM, Anders MJ. Injury; 2013 Oct 07; 44(10):1263-9. PubMed ID: 23845569 [Abstract] [Full Text] [Related] Page: [Next] [New Search]