These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
424 related items for PubMed ID: 18435638
1. In vitro study of percutaneous aortic valve replacement: selection of a tissue valve. Flecher EM, Curry JW, Joudinaud TM, Saber H, MacNett J, Ahlin A, Weber PA, Duran CM. J Card Surg; 2008; 23(3):234-8. PubMed ID: 18435638 [Abstract] [Full Text] [Related]
2. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep]. Song GM, Zhou JY, Hu SS, Cui JW, Song YH, Tang Y, Zhang Y, Jiang H, Yuan WM, Song XY. Zhonghua Yi Xue Za Zhi; 2008 Jul 29; 88(29):2059-63. PubMed ID: 19080436 [Abstract] [Full Text] [Related]
3. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves. Gerosa G, Tarzia V, Rizzoli G, Bottio T. J Thorac Cardiovasc Surg; 2006 May 29; 131(5):1058-64. PubMed ID: 16678590 [Abstract] [Full Text] [Related]
4. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position. Babin-Ebell J, Sievers HH, Misfeld M, Runge M, Vogt PR, Scharfschwerdt M. J Heart Valve Dis; 2008 Sep 29; 17(5):566-70. PubMed ID: 18980091 [Abstract] [Full Text] [Related]
5. Transapical aortic valve implantation: an animal feasibility study. Dewey TM, Walther T, Doss M, Brown D, Ryan WH, Svensson L, Mihaljevic T, Hambrecht R, Schuler G, Wimmer-Greinecker G, Mohr FW, Mack MJ. Ann Thorac Surg; 2006 Jul 29; 82(1):110-6. PubMed ID: 16798200 [Abstract] [Full Text] [Related]
6. Suboptimal geometrical implantation of biological aortic valves provokes functional deficits. Kuehnel RU, Wendt MO, Jainski U, Hartrumpf M, Pohl M, Albes JM. Interact Cardiovasc Thorac Surg; 2010 Jun 29; 10(6):971-5; discussion 975. PubMed ID: 20233809 [Abstract] [Full Text] [Related]
7. Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro study. Flecher EM, Curry JW, Joudinaud TM, Kegel CL, Weber PA, Duran CM. Eur J Cardiothorac Surg; 2007 Aug 29; 32(2):291-4; discussion 295. PubMed ID: 17561412 [Abstract] [Full Text] [Related]
8. A novel pulse duplicator system: evaluation of different valve prostheses. Haaf P, Steiner M, Attmann T, Pfister G, Cremer J, Lutter G. Thorac Cardiovasc Surg; 2009 Feb 29; 57(1):10-7. PubMed ID: 19169990 [Abstract] [Full Text] [Related]
9. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus. Wagner IM, Eichinger WB, Bleiziffer S, Botzenhardt F, Gebauer I, Guenzinger R, Bauernschmitt R, Lange R. J Thorac Cardiovasc Surg; 2007 May 29; 133(5):1234-41. PubMed ID: 17467435 [Abstract] [Full Text] [Related]
10. The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests. Bottio T, Tarzia V, Rizzoli G, Gerosa G. Interact Cardiovasc Thorac Surg; 2008 Oct 29; 7(5):750-4. PubMed ID: 18628343 [Abstract] [Full Text] [Related]
11. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro. Jennings LM, Butterfield M, Walker PG, Watterson KG, Fisher J. J Heart Valve Dis; 2001 Mar 29; 10(2):269-75. PubMed ID: 11297215 [Abstract] [Full Text] [Related]
12. The in vitro hydrodynamic characteristics of the porcine pulmonary valve and root with regard to the ross procedure. Nagy ZL, Fisher J, Walker PG, Watterson KG. J Thorac Cardiovasc Surg; 2000 Aug 29; 120(2):284-9. PubMed ID: 10917944 [Abstract] [Full Text] [Related]
13. [Transapical approach for aortic stented valve implantation: experimental results]. Flecher EM, Joudinaud TM, Curry JW, Solis J, Lopez J, Kegel C, Weber P, Duran C. Ann Cardiol Angeiol (Paris); 2007 Jun 29; 56(3):122-5. PubMed ID: 17524346 [Abstract] [Full Text] [Related]
14. Transapical implantation of a novel self-expanding sutureless aortic valve prosthesis. Stalder M, Suri RM, Kraehenbuehl ES, Hellige G, Wenaweser P, Zobrist C, Schaff HV, Carrel TP. J Heart Valve Dis; 2010 Mar 29; 19(2):182-7; discussion 188. PubMed ID: 20369501 [Abstract] [Full Text] [Related]
15. The influence of stenting on the behavior of amino-oleic acid-treated, glutaraldehyde-fixed porcine aortic valves in a sheep model. Ozaki S, Herijgers P, Verbeken E, Van Lommel A, Nishida T, Perek B, Zietkiewicz M, Leunens V, Flameng W. J Heart Valve Dis; 2000 Jul 29; 9(4):552-9; discussion 559-60. PubMed ID: 10947049 [Abstract] [Full Text] [Related]