These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Variation in mouthguard thickness due to different heating conditions during fabrication. Takahashi M, Koide K, Mizuhashi F. J Prosthodont Res; 2013 Jul; 57(3):179-85. PubMed ID: 23773377 [Abstract] [Full Text] [Related]
23. Forces transmitted through EVA mouthguard materials of different types and thickness. Westerman B, Stringfellow PM, Eccleston JA. Aust Dent J; 1995 Dec; 40(6):389-91. PubMed ID: 8615745 [Abstract] [Full Text] [Related]
25. Impact energy absorption of three mouthguard materials in three environments. Lunt DR, Mendel DA, Brantley WA, Michael Beck F, Huja S, Schriever SD, Grentzer TH, Alapati SB. Dent Traumatol; 2010 Feb; 26(1):23-9. PubMed ID: 20089058 [Abstract] [Full Text] [Related]
26. Method for effectively maintaining the thickness of mouthguards fabricated using EVA sheets and a circle tray: influence of grooved sheet and heating conditions. Takahashi M, Koide K, Iwasaki S. Dent Traumatol; 2016 Jun; 32(3):206-11. PubMed ID: 26446254 [Abstract] [Full Text] [Related]
27. Optimal heating condition of ethylene-vinyl acetate co-polymer mouthguard sheet in vacuum-pressure formation. Takahashi M, Koide K, Suzuki H, Iwasaki S. Dent Traumatol; 2016 Aug; 32(4):311-5. PubMed ID: 26635146 [Abstract] [Full Text] [Related]
30. Effect of the anteroposterior position of the model on fabricated mouthguard thickness: Part 2 Influence of sheet thickness and material. Takahashi M, Bando Y. Dent Traumatol; 2018 Oct; 34(5):370-377. PubMed ID: 29932508 [Abstract] [Full Text] [Related]
31. Effective thermoforming method for maintaining mouthguard thickness with a circular sheet using a circular frame. Takahashi M, Bando Y. Dent Traumatol; 2022 Aug; 38(4):325-331. PubMed ID: 35276018 [Abstract] [Full Text] [Related]
32. Impact energy absorption of three mouthguard materials in an aqueous environment. Mendel DA, Ucar Y, Brantley WA, Rashid RG, Harrell SL, Grentzer TH. Dent Traumatol; 2009 Feb; 25(1):130-5. PubMed ID: 19208026 [Abstract] [Full Text] [Related]
33. Optimal heating conditions for forming a mouthguard using a circle tray: effect of different conditions on the thickness and fit of formed mouthguards. Takahashi M, Koide K, Mizuhashi F. J Prosthodont Res; 2014 Jul; 58(3):171-6. PubMed ID: 24780307 [Abstract] [Full Text] [Related]
34. The influence of working cast residual moisture and temperature on the fit of vacuum-forming athletic mouth guards. Yonehata Y, Maeda Y, Machi H, Sakaguchi RL. J Prosthet Dent; 2003 Jan; 89(1):23-7. PubMed ID: 12589282 [Abstract] [Full Text] [Related]
35. The influence of impact object characteristics on impact force and force absorption by mouthguard material. Takeda T, Ishigami K, Shintaro K, Nakajima K, Shimada A, Regner CW. Dent Traumatol; 2004 Feb; 20(1):12-20. PubMed ID: 14998410 [Abstract] [Full Text] [Related]
36. Mechanical Safety of Embedded Electronics for In-body Wearables: A Smart Mouthguard Study. Bridgman H, Kwong MT, Bergmann JHM. Ann Biomed Eng; 2019 Aug; 47(8):1725-1737. PubMed ID: 31025132 [Abstract] [Full Text] [Related]
37. Prioritizing model trimming to prevent thinning during mouthguard thermoforming: Influence of increased height associated with an acute model angle. Takahashi M, Bando Y. Dent Traumatol; 2023 Feb; 39(1):11-18. PubMed ID: 36251443 [Abstract] [Full Text] [Related]
38. Beneficial effects of air inclusions on the performance of ethylene vinyl acetate (EVA) mouthguard material. Westerman B, Stringfellow PM, Eccleston JA. Br J Sports Med; 2002 Feb; 36(1):51-3. PubMed ID: 11867493 [Abstract] [Full Text] [Related]
39. Shape change in mouthguard sheets during thermoforming. Takahashi M, Koide K, Satoh Y, Iwasaki S. Dent Traumatol; 2016 Oct; 32(5):379-84. PubMed ID: 26833572 [Abstract] [Full Text] [Related]