These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Brachytherapy dosimetry parameters calculated for a 131Cs source. Rivard MJ. Med Phys; 2007 Feb; 34(2):754-62. PubMed ID: 17388193 [Abstract] [Full Text] [Related]
3. Dosimetry for 131Cs and 125I seeds in solid water phantom using radiochromic EBT film. Chiu-Tsao ST, Napoli JJ, Davis SD, Hanley J, Rivard MJ. Appl Radiat Isot; 2014 Sep; 92():102-14. PubMed ID: 25038559 [Abstract] [Full Text] [Related]
4. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models. Selvam TP, Sahoo S, Vishwakarma RS. Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459 [Abstract] [Full Text] [Related]
5. Dosimetric characteristics of the new RadioCoil 103Pd wire line source for use in permanent brachytherapy implants. Meigooni AS, Zhang H, Clark JR, Rachabatthula V, Koona RA. Med Phys; 2004 Nov; 31(11):3095-105. PubMed ID: 15587663 [Abstract] [Full Text] [Related]
6. Monte Carlo calculations and experimental measurements of the TG-43U1-recommended dosimetric parameters of 125I (Model IR-Seed2) brachytherapy source. Sheikholeslami S, Nedaie HA, Sadeghi M, Pourbeigy H, Shahzadi S, Zehtabian M, Hasani M, Meigooni AS. J Appl Clin Med Phys; 2016 Jul 08; 17(4):430-441. PubMed ID: 27455485 [Abstract] [Full Text] [Related]
10. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed. Lymperopoulou G, Papagiannis P, Sakelliou L, Karaiskos P, Sandilos P, Przykutta A, Baltas D. Med Phys; 2005 Nov 08; 32(11):3313-7. PubMed ID: 16370418 [Abstract] [Full Text] [Related]
12. Determination of task group 43 dosimetric parameters for CSM40 137Cs source for use in brachytherapy. Firoozabadi MM, Jimabadi E, Ghorbani M, Behmadi M. Radiol Phys Technol; 2018 Mar 08; 11(1):82-90. PubMed ID: 29299819 [Abstract] [Full Text] [Related]
13. EchoSeed Model 6733 Iodine-125 brachytherapy source: improved dosimetric characterization using the MCNP5 Monte Carlo code. Mosleh-Shirazi MA, Hadad K, Faghihi R, Baradaran-Ghahfarokhi M, Naghshnezhad Z, Meigooni AS. Med Phys; 2012 Aug 08; 39(8):4653-9. PubMed ID: 22894389 [Abstract] [Full Text] [Related]
17. Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed brachytherapy source. Kennedy RM, Davis SD, Micka JA, DeWerd LA. Med Phys; 2010 Apr 08; 37(4):1681-8. PubMed ID: 20443489 [Abstract] [Full Text] [Related]
18. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source. Meigooni AS, Hayes JL, Zhang H, Sowards K. Med Phys; 2002 Sep 08; 29(9):2152-8. PubMed ID: 12349937 [Abstract] [Full Text] [Related]
19. Monte Carlo dosimetric study of the medium dose rate CSM40 source. Vijande J, Granero D, Perez-Calatayud J, Ballester F. Appl Radiat Isot; 2013 Dec 08; 82():283-8. PubMed ID: 24121444 [Abstract] [Full Text] [Related]
20. An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect. Abboud F, Scalliet P, Vynckier S. Med Phys; 2008 Dec 08; 35(12):5841-50. PubMed ID: 19175140 [Abstract] [Full Text] [Related] Page: [Next] [New Search]