These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up. Zwartelé RE, Olsthoorn PG, Pöll RG, Brand R, Doets HC. Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793 [Abstract] [Full Text] [Related]
3. Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis. Nieuwenhuis JJ, Malefijt Jde W, Hendriks JC, Gosens T, Bonnet M. Acta Orthop Belg; 2005 Jun; 71(3):294-302. PubMed ID: 16035702 [Abstract] [Full Text] [Related]
6. Good stability and minimal osteolysis with a biconical threaded cup at 10 years. Zweymüller KA, Steindl M, Schwarzinger U. Clin Orthop Relat Res; 2007 Oct; 463():128-37. PubMed ID: 17960675 [Abstract] [Full Text] [Related]
7. A comparison of a second- and a third-generation modular cup design: is new improved? Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH, Engh CA, Engh CA. J Arthroplasty; 2010 Jun; 25(4):514-21. PubMed ID: 19361949 [Abstract] [Full Text] [Related]
8. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Coathup MJ, Blackburn J, Goodship AE, Cunningham JL, Smith T, Blunn GW. Biomaterials; 2005 Jul; 26(19):4161-9. PubMed ID: 15664643 [Abstract] [Full Text] [Related]
9. Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years. Reikerås O, Gunderson RB. Acta Orthop Scand; 2002 Jan; 73(1):104-8. PubMed ID: 11928902 [Abstract] [Full Text] [Related]
10. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]. Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R. Acta Chir Orthop Traumatol Cech; 2002 Jan; 69(1):8-15. PubMed ID: 11951572 [Abstract] [Full Text] [Related]
11. Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years. Reikerås O, Gunderson RB. Arch Orthop Trauma Surg; 2006 Oct; 126(8):503-8. PubMed ID: 16799792 [Abstract] [Full Text] [Related]
12. Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up. Cheung KW, Yung SH, Wong KC, Chiu KH. J Arthroplasty; 2005 Aug; 20(5):627-31. PubMed ID: 16309999 [Abstract] [Full Text] [Related]
13. Extra-large press-fit cups without screws for acetabular revision. Obenaus C, Winkler H, Girtler R, Huber M, Schwägerl W. J Arthroplasty; 2003 Apr; 18(3):271-7. PubMed ID: 12728417 [Abstract] [Full Text] [Related]