These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


714 related items for PubMed ID: 18557743

  • 1. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation.
    Working Group on Non-invasive Haemodynamic Monitoring in Paediatrics, Knirsch W, Kretschmar O, Tomaske M, Stutz K, Nagdyman N, Balmer C, Schmitz A, Berger F, Bauersfeld U, Weiss M.
    Anaesthesia; 2008 Aug; 63(8):851-5. PubMed ID: 18557743
    [Abstract] [Full Text] [Related]

  • 2. Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects.
    Tomaske M, Knirsch W, Kretschmar O, Balmer C, Woitzek K, Schmitz A, Bauersfeld U, Weiss M, Working Group on Noninvasive Haemodynamic Monitoring in Paediatrics.
    Eur J Anaesthesiol; 2009 May; 26(5):412-5. PubMed ID: 19276980
    [Abstract] [Full Text] [Related]

  • 3. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle.
    Pauli C, Fakler U, Genz T, Hennig M, Lorenz HP, Hess J.
    Intensive Care Med; 2002 Jul; 28(7):947-52. PubMed ID: 12122535
    [Abstract] [Full Text] [Related]

  • 4. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C, Rex S, Wouters PF.
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [Abstract] [Full Text] [Related]

  • 5. Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.
    Jaeggi P, Hofer CK, Klaghofer R, Fodor P, Genoni M, Zollinger A.
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):217-20. PubMed ID: 12698405
    [Abstract] [Full Text] [Related]

  • 6. Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery.
    Parra V, Fita G, Rovira I, Matute P, Gomar C, Paré C.
    Eur J Anaesthesiol; 2008 Feb; 25(2):135-43. PubMed ID: 17672920
    [Abstract] [Full Text] [Related]

  • 7. Arterial pulse wave analysis: An accurate means of determining cardiac output in children.
    Kim JJ, Dreyer WJ, Chang AC, Breinholt JP, Grifka RG.
    Pediatr Crit Care Med; 2006 Nov; 7(6):532-5. PubMed ID: 17006382
    [Abstract] [Full Text] [Related]

  • 8. Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter.
    Lafanechère A, Albaladejo P, Raux M, Geeraerts T, Bocquet R, Wernet A, Castier Y, Marty J.
    J Cardiothorac Vasc Anesth; 2006 Feb; 20(1):26-30. PubMed ID: 16458209
    [Abstract] [Full Text] [Related]

  • 9. [Monitoring cardiac output: esophageal doppler vs thermodilution].
    Leone D, Servillo G, De Robertis E, Rossano F, Tufano R.
    Minerva Anestesiol; 1998 Feb; 64(7-8):351-6. PubMed ID: 9796245
    [Abstract] [Full Text] [Related]

  • 10. Constant postoperative monitoring of cardiac output after correction of congenital heart defects.
    Keagy BA, Wilcox BR, Lucas CL, Hsiao HS, Henry GW, Baudino M, Bornzin G.
    J Thorac Cardiovasc Surg; 1987 May; 93(5):658-64. PubMed ID: 3553745
    [Abstract] [Full Text] [Related]

  • 11. The impact of intra-aortic balloon pumping on cardiac output determination by pulmonary arterial and transpulmonary thermodilution in pigs.
    Janda M, Scheeren TW, Bajorat J, Westphal B, Vagts DA, Pohl B, Popescu C, Hofmockel R.
    J Cardiothorac Vasc Anesth; 2006 Jun; 20(3):320-4. PubMed ID: 16750730
    [Abstract] [Full Text] [Related]

  • 12. Transoesophageal echo-Doppler vs. thermodilution cardiac output measurement during hepatic vascular exclusion in liver transplantation.
    Boucaud C, Bouffard Y, Dumortier J, Gaillac N, Sagnard P, Graber MC, Adham M, Boillot O.
    Eur J Anaesthesiol; 2008 Jun; 25(6):485-9. PubMed ID: 18298871
    [Abstract] [Full Text] [Related]

  • 13. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A, Barnett AG, Mullany D, Fraser JF.
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [Abstract] [Full Text] [Related]

  • 14. Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device.
    Mets B, Frumento RJ, Bennett-Guerrero E, Naka Y.
    J Cardiothorac Vasc Anesth; 2002 Dec; 16(6):727-30. PubMed ID: 12486654
    [Abstract] [Full Text] [Related]

  • 15. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
    Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld AB.
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
    [Abstract] [Full Text] [Related]

  • 16. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique.
    Hofer CK, Bühlmann S, Klaghofer R, Genoni M, Zollinger A.
    Acta Anaesthesiol Scand; 2004 May; 48(5):653-7. PubMed ID: 15101865
    [Abstract] [Full Text] [Related]

  • 17. Comparison of continuous with intermittent bolus thermodilution cardiac output measurements.
    Ditmyer CE, Shively M, Burns DB, Reichman RT.
    Am J Crit Care; 1995 Nov; 4(6):460-5. PubMed ID: 8556087
    [Abstract] [Full Text] [Related]

  • 18. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery.
    Fakler U, Pauli Ch, Balling G, Lorenz HP, Eicken A, Hennig M, Hess J.
    J Thorac Cardiovasc Surg; 2007 Jan; 133(1):224-8. PubMed ID: 17198817
    [Abstract] [Full Text] [Related]

  • 19. Measuring cardiac output during dobutamine infusion after off-pump coronary artery bypass: comparison of transesophageal echo-Doppler and thermodilution.
    Husedzinović I, Barisin S, Tonković D, Sostarić S.
    Croat Med J; 2002 Dec; 43(6):680-4. PubMed ID: 12476476
    [Abstract] [Full Text] [Related]

  • 20. Cardiac output--pulse contour analysis vs. pulmonary artery thermodilution.
    Ostergaard M, Nielsen J, Rasmussen JP, Berthelsen PG.
    Acta Anaesthesiol Scand; 2006 Oct; 50(9):1044-9. PubMed ID: 16987334
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 36.