These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Zinc oxide/redox mediator composite films-based sensor for electrochemical detection of important biomolecules. Tang CF, Kumar SA, Chen SM. Anal Biochem; 2008 Sep 15; 380(2):174-83. PubMed ID: 18577367 [Abstract] [Full Text] [Related]
6. Acid yellow 9 as a dispersing agent for carbon nanotubes: preparation of redox polymer-carbon nanotube composite film and its sensing application towards ascorbic acid and dopamine. Kumar SA, Wang SF, Yang TC, Yeh CT. Biosens Bioelectron; 2010 Aug 15; 25(12):2592-7. PubMed ID: 20462750 [Abstract] [Full Text] [Related]
7. Poly(4-amino-1-1'-azobenzene-3, 4'-disulfonic acid) coated electrode for selective detection of dopamine from its interferences. Kumar SA, Tang CF, Chen SM. Talanta; 2008 Jan 15; 74(4):860-6. PubMed ID: 18371720 [Abstract] [Full Text] [Related]
8. Electrochemical synthesis of polyaniline nano-networks on p-aminobenzene sulfonic acid functionalized glassy carbon electrode Its use for the simultaneous determination of ascorbic acid and uric acid. Zhang L, Zhang C, Lian J. Biosens Bioelectron; 2008 Dec 01; 24(4):690-5. PubMed ID: 18706798 [Abstract] [Full Text] [Related]
9. Electroanalytical determination of acetaminophen using nano-TiO(2)/polymer coated electrode in the presence of dopamine. Kumar SA, Tang CF, Chen SM. Talanta; 2008 Sep 15; 76(5):997-1005. PubMed ID: 18761146 [Abstract] [Full Text] [Related]
10. Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid and uric acid. Balamurugan A, Chen SM. Anal Chim Acta; 2007 Jul 16; 596(1):92-8. PubMed ID: 17616245 [Abstract] [Full Text] [Related]
11. Easy modification of glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid. Thiagarajan S, Tsai TH, Chen SM. Biosens Bioelectron; 2009 Apr 15; 24(8):2712-5. PubMed ID: 19162467 [Abstract] [Full Text] [Related]
13. [Selective determination of norepinephrine by a cyclic voltammetric method using poly-proline-modified electrodes]. Ma XY, Chao Z. Nan Fang Yi Ke Da Xue Xue Bao; 2008 Aug 15; 28(8):1454-7. PubMed ID: 18753086 [Abstract] [Full Text] [Related]
15. Fabrication of cytochrome c-poly(5-amino-2-napthalenesulfonic acid) electrode by one step procedure and direct electrochemistry of cytochrome c. Balamurugan A, Chen SM. Biosens Bioelectron; 2008 Dec 01; 24(4):982-6. PubMed ID: 18774287 [Abstract] [Full Text] [Related]
16. Carbon nanotubes-polymer-redox mediator hybrid thin film for electrocatalytic sensing. Raj CR, Chakraborty S. Biosens Bioelectron; 2006 Dec 15; 22(5):700-6. PubMed ID: 16584882 [Abstract] [Full Text] [Related]
17. Electrochemical determination of uric acid at ordered mesoporous carbon functionalized with ferrocenecarboxylic acid-modified electrode. Ndamanisha JC, Guo L. Biosens Bioelectron; 2008 Jun 15; 23(11):1680-5. PubMed ID: 18339534 [Abstract] [Full Text] [Related]
18. Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode. Deng C, Chen J, Chen X, Xiao C, Nie L, Yao S. Biosens Bioelectron; 2008 Mar 14; 23(8):1272-7. PubMed ID: 18178424 [Abstract] [Full Text] [Related]
19. Determination of dopamine in the presence of ascorbic acid using poly(3,5-dihydroxy benzoic acid) film modified electrode. Hou S, Zheng N, Feng H, Li X, Yuan Z. Anal Biochem; 2008 Oct 15; 381(2):179-84. PubMed ID: 18455490 [Abstract] [Full Text] [Related]
20. Selective electrochemical sensor for folic acid at physiological pH using ultrathin electropolymerized film of functionalized thiadiazole modified glassy carbon electrode. Kalimuthu P, John SA. Biosens Bioelectron; 2009 Aug 15; 24(12):3575-80. PubMed ID: 19523810 [Abstract] [Full Text] [Related] Page: [Next] [New Search]