These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
560 related items for PubMed ID: 18640027
1. An enhanced glucose biosensor using charge transfer techniques. Lee SR, Sawada K, Takao H, Ishida M. Biosens Bioelectron; 2008 Dec 01; 24(4):650-6. PubMed ID: 18640027 [Abstract] [Full Text] [Related]
2. Fabrication of a highly sensitive penicillin sensor based on charge transfer techniques. Lee SR, Rahman MM, Sawada K, Ishida M. Biosens Bioelectron; 2009 Mar 15; 24(7):1877-82. PubMed ID: 18977651 [Abstract] [Full Text] [Related]
3. A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor. Shervedani RK, Mehrjardi AH, Zamiri N. Bioelectrochemistry; 2006 Oct 15; 69(2):201-8. PubMed ID: 16580891 [Abstract] [Full Text] [Related]
4. A glucose biosensor based on Prussian blue/chitosan hybrid film. Wang X, Gu H, Yin F, Tu Y. Biosens Bioelectron; 2009 Jan 01; 24(5):1527-30. PubMed ID: 19010659 [Abstract] [Full Text] [Related]
5. Direct electrochemistry of glucose oxidase in a colloid Au-dihexadecylphosphate composite film and its application to develop a glucose biosensor. Wu Y, Hu S. Bioelectrochemistry; 2007 May 01; 70(2):335-41. PubMed ID: 16766233 [Abstract] [Full Text] [Related]
6. New glucose biosensor based on glucose oxidase-immobilized gelatin film coated electrodes. Sungur S, Emregül E, Günendi G, Numanoğlu Y. J Biomater Appl; 2004 Apr 01; 18(4):265-77. PubMed ID: 15070514 [Abstract] [Full Text] [Related]
7. Application of polymaleimidostyrene as a convenient immobilization reagent of enzyme in biosensor. Uchiyama S, Tomita R, Sekioka N, Imaizumi E, Hamana H, Hagiwara T. Bioelectrochemistry; 2006 May 01; 68(2):119-25. PubMed ID: 16039167 [Abstract] [Full Text] [Related]
8. Glucose oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing. Kang X, Wang J, Wu H, Aksay IA, Liu J, Lin Y. Biosens Bioelectron; 2009 Dec 15; 25(4):901-5. PubMed ID: 19800781 [Abstract] [Full Text] [Related]
9. The potential use of hydrazine as an alternative to peroxidase in a biosensor: comparison between hydrazine and HRP-based glucose sensors. Rahman MA, Won MS, Shim YB. Biosens Bioelectron; 2005 Aug 15; 21(2):257-65. PubMed ID: 16023952 [Abstract] [Full Text] [Related]
10. Extended-gate FET-based enzyme sensor with ferrocenyl-alkanethiol modified gold sensing electrode. Ishige Y, Shimoda M, Kamahori M. Biosens Bioelectron; 2009 Jan 01; 24(5):1096-102. PubMed ID: 18672358 [Abstract] [Full Text] [Related]
11. Development of a novel, sensitive amperometric-FIA glucose biosensor by packing up the amperometric cell with glucose oxidase modified anion exchange resin. Su Y, Huang W, Hu R, Ding H, Hu K. Biosens Bioelectron; 2009 Apr 15; 24(8):2665-70. PubMed ID: 19264473 [Abstract] [Full Text] [Related]
13. A noninterference polypyrrole glucose biosensor. Chen C, Jiang Y, Kan J. Biosens Bioelectron; 2006 Dec 15; 22(5):639-43. PubMed ID: 16540308 [Abstract] [Full Text] [Related]
15. A super highly sensitive glucose biosensor based on Au nanoparticles-AgCl@polyaniline hybrid material. Yan W, Feng X, Chen X, Hou W, Zhu JJ. Biosens Bioelectron; 2008 Feb 28; 23(7):925-31. PubMed ID: 18093821 [Abstract] [Full Text] [Related]
16. A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink. Crouch E, Cowell DC, Hoskins S, Pittson RW, Hart JP. Biosens Bioelectron; 2005 Nov 15; 21(5):712-8. PubMed ID: 16242609 [Abstract] [Full Text] [Related]
17. A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized on nitrogen-doped carbon nanotubes. Deng S, Jian G, Lei J, Hu Z, Ju H. Biosens Bioelectron; 2009 Oct 15; 25(2):373-7. PubMed ID: 19683424 [Abstract] [Full Text] [Related]
20. Acetylcholinesterase-ISFET based system for the detection of acetylcholine and acetylcholinesterase inhibitors. Hai A, Ben-Haim D, Korbakov N, Cohen A, Shappir J, Oren R, Spira ME, Yitzchaik S. Biosens Bioelectron; 2006 Dec 15; 22(5):605-12. PubMed ID: 16529923 [Abstract] [Full Text] [Related] Page: [Next] [New Search]