These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


676 related items for PubMed ID: 18761477

  • 1. The technique, validity and clinical use of the sweep VEP.
    Almoqbel F, Leat SJ, Irving E.
    Ophthalmic Physiol Opt; 2008 Sep; 28(5):393-403. PubMed ID: 18761477
    [Abstract] [Full Text] [Related]

  • 2. [Measuring vernier acuity and motion perception with the parameter sweep VEP].
    Wesemann W, Norcia AM, Manny RE.
    Klin Monbl Augenheilkd; 1996 Jan; 208(1):11-7. PubMed ID: 8839339
    [Abstract] [Full Text] [Related]

  • 3. Validation study of VEP vernier acuity in normal-vision and amblyopic adults.
    Hou C, Good WV, Norcia AM.
    Invest Ophthalmol Vis Sci; 2007 Sep; 48(9):4070-8. PubMed ID: 17724189
    [Abstract] [Full Text] [Related]

  • 4. Screening and diagnosis of optic pathway gliomas in children with neurofibromatosis type 1 by using sweep visual evoked potentials.
    Chang BC, Mirabella G, Yagev R, Banh M, Mezer E, Parkin PC, Westall CA, Buncic JR.
    Invest Ophthalmol Vis Sci; 2007 Jun; 48(6):2895-902. PubMed ID: 17525226
    [Abstract] [Full Text] [Related]

  • 5. Visual impairment in children with spastic cerebral palsy measured by psychophysical and electrophysiological grating acuity tests.
    Costa MF, Ventura DF.
    Dev Neurorehabil; 2012 Jun; 15(6):414-24. PubMed ID: 23030659
    [Abstract] [Full Text] [Related]

  • 6. Normal vernier acuity in infants with delayed visual maturation.
    Good WV, Hou C.
    Am J Ophthalmol; 2004 Jul; 138(1):140-2. PubMed ID: 15234296
    [Abstract] [Full Text] [Related]

  • 7. [Sweep-VEP: a new method for objective visual assessment in small children].
    Prünte-Glowazki A, Zemon V.
    Klin Monbl Augenheilkd; 1993 May; 202(5):422-4. PubMed ID: 8377406
    [Abstract] [Full Text] [Related]

  • 8. Methods of visual acuity determination with the spatial frequency sweep visual evoked potential.
    Ridder WH.
    Doc Ophthalmol; 2004 Nov; 109(3):239-47. PubMed ID: 15957609
    [Abstract] [Full Text] [Related]

  • 9. The assessment of visual acuity in children with periventricular damage: a comparison of behavioural and electrophysiological techniques.
    Tinelli F, Pei F, Guzzetta A, Bancale A, Mazzotti S, Baldassi S, Cioni G.
    Vision Res; 2008 May; 48(10):1233-41. PubMed ID: 18384834
    [Abstract] [Full Text] [Related]

  • 10. A comparison of contrast sensitivity and sweep visual evoked potential (sVEP) acuity estimates in normal humans.
    Ridder WH.
    Doc Ophthalmol; 2019 Dec; 139(3):207-219. PubMed ID: 31414313
    [Abstract] [Full Text] [Related]

  • 11. [Effects of temporal frequency on the sweep pattern visual evoked response acuity].
    Liu RJ, Chen JM, Xia WT, Fan LH, Zhu GY.
    Fa Yi Xue Za Zhi; 2009 Dec; 25(6):409-11. PubMed ID: 20225613
    [Abstract] [Full Text] [Related]

  • 12. Objective measurement of contrast sensitivity and visual acuity with the steady-state visual evoked potential.
    Strasburger H, Remky A, Murray IJ, Hadjizenonos C, Rentschler I.
    Ger J Ophthalmol; 1996 Jan; 5(1):42-52. PubMed ID: 8646179
    [Abstract] [Full Text] [Related]

  • 13. Detection of Amblyopia Using Sweep VEP Vernier and Grating Acuity.
    Hou C, Good WV, Norcia AM.
    Invest Ophthalmol Vis Sci; 2018 Mar 01; 59(3):1435-1442. PubMed ID: 29625467
    [Abstract] [Full Text] [Related]

  • 14. Similarities and differences between behavioral and electrophysiological visual acuity thresholds in healthy infants during the second half of the first year of life.
    Polevoy C, Muckle G, Séguin JR, Ouellet E, Saint-Amour D.
    Doc Ophthalmol; 2017 Apr 01; 134(2):99-110. PubMed ID: 28220265
    [Abstract] [Full Text] [Related]

  • 15. Real-time rapid acuity assessment using VEPs: development and validation of the step VEP technique.
    Mackay AM, Bradnam MS, Hamilton R, Elliot AT, Dutton GN.
    Invest Ophthalmol Vis Sci; 2008 Jan 01; 49(1):438-41. PubMed ID: 18172123
    [Abstract] [Full Text] [Related]

  • 16. Vision abnormalities in young children exposed prenatally to organic solvents.
    Till C, Westall CA, Koren G, Nulman I, Rovet JF.
    Neurotoxicology; 2005 Aug 01; 26(4):599-613. PubMed ID: 16054697
    [Abstract] [Full Text] [Related]

  • 17. Development of VEP Vernier acuity and grating acuity in human infants.
    Skoczenski AM, Norcia AM.
    Invest Ophthalmol Vis Sci; 1999 Sep 01; 40(10):2411-7. PubMed ID: 10476810
    [Abstract] [Full Text] [Related]

  • 18. [Comparison of several visual evoked potential tests in measuring normal adults' real visual acuity].
    Xia WT, Zhu GY.
    Fa Yi Xue Za Zhi; 2007 Aug 01; 23(4):254-7. PubMed ID: 17896513
    [Abstract] [Full Text] [Related]

  • 19. Measurement of position acuity in strabismus and amblyopia: specificity of the vernier VEP paradigm.
    Chen SI, Norcia AM, Pettet MW, Chandna A.
    Invest Ophthalmol Vis Sci; 2005 Dec 01; 46(12):4563-70. PubMed ID: 16303949
    [Abstract] [Full Text] [Related]

  • 20. Stimulus duration, neural adaptation, and sweep visual evoked potential acuity estimates.
    Ridder WH, McCulloch D, Herbert AM.
    Invest Ophthalmol Vis Sci; 1998 Dec 01; 39(13):2759-68. PubMed ID: 9856787
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 34.