These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


106 related items for PubMed ID: 1882182

  • 1. Use of calcium-titrated sodium heparinate for ionized calcium determination on plasma and whole blood (heparinized blood sampler B-129 Radiometer).
    Sachs C, Rabouine P, Chaneac M, Kindermans C, Dechaux M.
    Scand J Clin Lab Invest; 1991 May; 51(3):303-6. PubMed ID: 1882182
    [Abstract] [Full Text] [Related]

  • 2. In vitro evaluation of a heparinized blood sampler for ionized calcium measurement.
    Sachs C, Rabouine P, Chaneac M, Kindermans C, Dechaux M.
    Ann Clin Biochem; 1991 May; 28 ( Pt 3)():240-4. PubMed ID: 1872569
    [Abstract] [Full Text] [Related]

  • 3. Preanalytical errors in ionized calcium measurements induced by the use of liquid heparin.
    Sachs C, Rabouine P, Chaneac M, Kindermans C, Dechaux M, Falch-Christiansen T.
    Ann Clin Biochem; 1991 Mar; 28 ( Pt 2)():167-73. PubMed ID: 1859155
    [Abstract] [Full Text] [Related]

  • 4. Evaluation of capillaries for ionized calcium measurements.
    Sachs C, Rabouine P, Kindermans C, Dautzenberg MD, Dechaux M.
    Ann Clin Biochem; 1992 May; 29 ( Pt 3)():296-301. PubMed ID: 1610105
    [Abstract] [Full Text] [Related]

  • 5. Anticoagulant-induced preanalytical errors in ionized calcium determination on blood.
    Sachs C, Rabouine P, Chaneac M, Kindermans C, Dechaux M.
    Scand J Clin Lab Invest; 1989 Nov; 49(7):647-51. PubMed ID: 2609108
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Heparinization of samples for plasma ionized calcium measurement.
    Heining MP, Jordan WS.
    Crit Care Med; 1988 Jan; 16(1):67-8. PubMed ID: 3338281
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Interference in ionized calcium measurements by heparin salts.
    Landt M, Hortin GL, Smith CH, McClellan A, Scott MG.
    Clin Chem; 1994 Apr; 40(4):565-70. PubMed ID: 8149611
    [Abstract] [Full Text] [Related]

  • 12. Recommendation on sampling, transport, and storage for the determination of the concentration of ionized calcium in whole blood, plasma, and serum. IFC Scientific Division, Working Group on Ion-Selective Electrodes (WGSE).
    Boink AB, Buckley BM, Christiansen TF, Covington AK, Maas AH, Müller-Plathe O, Sachs C, Siggaard-Andersen O.
    J Int Fed Clin Chem; 1992 Sep; 4(4):147-52. PubMed ID: 10148305
    [Abstract] [Full Text] [Related]

  • 13. Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients.
    Chantler J, Cox DJ.
    Br J Anaesth; 1999 Nov; 83(5):810-2. PubMed ID: 10690149
    [Abstract] [Full Text] [Related]

  • 14. International Federation of Clinical Chemistry (IFCC), scientific division: IFCC recommendation on sampling transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.
    Boink AB, Buckley BM, Christiansen TF, Covington AK, Maas AH, Müller-Plathe O, Sachs C, Siggaard-Andersen O.
    Eur J Clin Chem Clin Biochem; 1991 Nov; 29(11):767-72. PubMed ID: 1782285
    [Abstract] [Full Text] [Related]

  • 15. International Federation of Clinical Chemistry (IFCC) scientific division IFCC recommendation. Recommendation on sampling, transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.
    Boink AB, Buckley BM, Christiansen TF, Covington AK, Maas AH, Müller-Plathe O, Sachs C, Siggaard-Andersen O.
    Ann Biol Clin (Paris); 1991 Nov; 49(8):434-8. PubMed ID: 1776715
    [Abstract] [Full Text] [Related]

  • 16. Electrolyte measurement in goats: Comparison of 2 blood gas analyzers and evaluation of the preanalytical blood sample preparation on measurement results.
    Luethy D, Hopster K.
    Tierarztl Prax Ausg G Grosstiere Nutztiere; 2020 Jun; 48(3):148-155. PubMed ID: 32557512
    [Abstract] [Full Text] [Related]

  • 17. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients.
    Wiese J, Didwania A, Kerzner R, Chernow B.
    Crit Care Med; 1997 Nov; 25(11):1847-50. PubMed ID: 9366768
    [Abstract] [Full Text] [Related]

  • 18. Electrolyte balanced heparin may produce a bias in the measurement of ionized calcium concentration in specimens with abnormally low protein concentration.
    Lyon ME, Guajardo M, Laha T, Malik S, Henderson PJ, Kenny MA.
    Clin Chim Acta; 1995 Jan 16; 233(1-2):105-13. PubMed ID: 7758198
    [No Abstract] [Full Text] [Related]

  • 19. Zinc heparin introduces a preanalytical error in the measurement of ionized calcium concentration.
    Lyon ME, Guajardo M, Laha T, Malik S, Henderson PJ, Kenny MA.
    Scand J Clin Lab Invest; 1995 Feb 16; 55(1):61-5. PubMed ID: 7624738
    [Abstract] [Full Text] [Related]

  • 20. Preanalytical procedures in the measurement of ionized calcium in serum and plasma.
    Kallner A.
    Eur J Clin Chem Clin Biochem; 1996 Jan 16; 34(1):53-8. PubMed ID: 8704036
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.