These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
353 related items for PubMed ID: 18932095
1. Calculated LET spectrum from antiproton beams stopping in water. Bassler N, Holzscheiter M. Acta Oncol; 2009; 48(2):223-6. PubMed ID: 18932095 [Abstract] [Full Text] [Related]
3. An antiproton simulation study using MCNPX for radiation therapy. Michael Handley S, Ahmad S. J Xray Sci Technol; 2011 Jan; 19(3):345-53. PubMed ID: 21876284 [Abstract] [Full Text] [Related]
4. Passive spectrometry of linear energy transfer: development and use. Spurný F, Molokanov AG, Bamblevski VP. Radiat Prot Dosimetry; 2004 Jan; 110(1-4):675-9. PubMed ID: 15353729 [Abstract] [Full Text] [Related]
5. A particle track-repeating algorithm for proton beam dose calculation. Li JS, Shahine B, Fourkal E, Ma CM. Phys Med Biol; 2005 Mar 07; 50(5):1001-10. PubMed ID: 15798272 [Abstract] [Full Text] [Related]
6. Comparison of optimized single and multifield irradiation plans of antiproton, proton and carbon ion beams. Bassler N, Kantemiris I, Karaiskos P, Engelke J, Holzscheiter MH, Petersen JB. Radiother Oncol; 2010 Apr 07; 95(1):87-93. PubMed ID: 20304512 [Abstract] [Full Text] [Related]
7. Low and high LET dose components in carbon beam. Gudowska I, Kempe J, Sobolevsky N. Radiat Prot Dosimetry; 2006 Apr 07; 122(1-4):483-4. PubMed ID: 17151009 [Abstract] [Full Text] [Related]
9. Elevated LET components in clinical proton beams. Grassberger C, Paganetti H. Phys Med Biol; 2011 Oct 21; 56(20):6677-91. PubMed ID: 21965268 [Abstract] [Full Text] [Related]
10. Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code. Guan F, Peeler C, Bronk L, Geng C, Taleei R, Randeniya S, Ge S, Mirkovic D, Grosshans D, Mohan R, Titt U. Med Phys; 2015 Nov 21; 42(11):6234-47. PubMed ID: 26520716 [Abstract] [Full Text] [Related]
11. The antiproton depth-dose curve in water. Bassler N, Holzscheiter MH, Jäkel O, Knudsen HV, Kovacevic S. Phys Med Biol; 2008 Feb 07; 53(3):793-805. PubMed ID: 18199915 [Abstract] [Full Text] [Related]
12. LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry. Kirby D, Green S, Palmans H, Hugtenburg R, Wojnecki C, Parker D. Phys Med Biol; 2010 Jan 21; 55(2):417-33. PubMed ID: 20019399 [Abstract] [Full Text] [Related]
13. The biological effectiveness of antiproton irradiation. Holzscheiter MH, Bassler N, Agazaryan N, Beyer G, Blackmore E, DeMarco JJ, Doser M, Durand RE, Hartley O, Iwamoto KS, Knudsen HV, Landua R, Maggiore C, McBride WH, Møller SP, Petersen J, Skarsgard LD, Smathers JB, Solberg TD, Uggerhøj UI, Vranjes S, Withers HR, Wong M, Wouters BG. Radiother Oncol; 2006 Dec 21; 81(3):233-42. PubMed ID: 17069916 [Abstract] [Full Text] [Related]
15. Contribution of secondary particles to the dose in 12C radiotherapy and other heavy ion beams. Jadrnícková I, Spurny F, Molokanov AG. Radiat Prot Dosimetry; 2007 Dec 21; 126(1-4):657-9. PubMed ID: 17504750 [Abstract] [Full Text] [Related]
16. A beam source model for scanned proton beams. Kimstrand P, Traneus E, Ahnesjö A, Grusell E, Glimelius B, Tilly N. Phys Med Biol; 2007 Jun 07; 52(11):3151-68. PubMed ID: 17505095 [Abstract] [Full Text] [Related]