These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A preconcentration system using polyamine Metalfix-Chelamine resin for the on-line determination of palladium(II) and platinum(IV) by inductively coupled plasma optical emission spectrometry. Muzikar M, Fontàs C, Hidalgo M, Havel J, Salvadó V. Talanta; 2006 Dec 15; 70(5):1081-6. PubMed ID: 18970884 [Abstract] [Full Text] [Related]
6. Development of an on-line preconcentration system for zinc determination in biological samples. Dutra RL, Maltez HF, Carasek E. Talanta; 2006 Apr 15; 69(2):488-93. PubMed ID: 18970593 [Abstract] [Full Text] [Related]
8. Optimization of dispersive liquid-liquid microextraction for the selective determination of trace amounts of palladium by flame atomic absorption spectroscopy. Kokya TA, Farhadi K. J Hazard Mater; 2009 Sep 30; 169(1-3):726-33. PubMed ID: 19423217 [Abstract] [Full Text] [Related]
10. Separation and preconcentration of trace manganese from various samples with Amberlyst 36 column and determination by flame atomic absorption spectrometry. Kendüzler E, Türker AR, Yalçınkaya O. Talanta; 2006 Jun 15; 69(4):835-40. PubMed ID: 18970645 [Abstract] [Full Text] [Related]
12. On-line preconcentration and recovery of palladium from waters using polyaniline (PANI) loaded in mini-column and determination by ICP-MS; elimination of spectral interferences. Krishna MV, Ranjit M, Chandrasekaran K, Venkateswarlu G, Karunasagar D. Talanta; 2009 Oct 15; 79(5):1454-63. PubMed ID: 19635384 [Abstract] [Full Text] [Related]
14. On-line preconcentration using a resin functionalized with 3,4-dihydroxybenzoic acid for the determination of trace elements in biological samples by thermospray flame furnace atomic absorption spectrometry. Lemos VA, Bezerra MA, Amorim FA. J Hazard Mater; 2008 Sep 15; 157(2-3):613-9. PubMed ID: 18280033 [Abstract] [Full Text] [Related]
15. Flow injection on-line solid phase extractive preconcentration of palladium(II) in dust and rock samples using exfoliated graphite packed microcolumns and determination by flame atomic absorption spectrometry. Praveen RS, Daniel S, Rao TP, Sampath S, Rao KS. Talanta; 2006 Sep 15; 70(2):437-43. PubMed ID: 18970789 [Abstract] [Full Text] [Related]
16. Enrichment of trace amounts of copper(II) ions in water samples using octadecyl silica disks modified by a Schiff base ionophore prior to flame atomic absorption spectrometric determination. Fathi SA, Yaftian MR. J Hazard Mater; 2009 May 15; 164(1):133-7. PubMed ID: 18778894 [Abstract] [Full Text] [Related]
17. Flame atomic absorption determination of palladium in solutions after preconcentration using octadecyl silica membrane disks modified by thioridazine.HCl. Farhadi K, Teimouri G. Talanta; 2005 Feb 28; 65(4):925-9. PubMed ID: 18969890 [Abstract] [Full Text] [Related]
18. Determination of trace metals in urine with an on-line ultrasound-assisted digestion system combined with a flow-injection preconcentration manifold coupled to flame atomic absorption spectrometry. Cespón-Romero RM, Yebra-Biurrun MC. Anal Chim Acta; 2008 Feb 25; 609(2):184-91. PubMed ID: 18261513 [Abstract] [Full Text] [Related]
19. Trace level determination of cadmium in wine by on-line preconcentration in a 5-Br-PADAP functionalized wool-packed microcolumn coupled to flame atomic absorption spectrometry. Monasterio RP, Wuilloud RG. Talanta; 2009 Oct 15; 79(5):1484-8. PubMed ID: 19635388 [Abstract] [Full Text] [Related]
20. Flow injection preconcentration system using a new functionalized resin for determination of cadmium and nickel in tobacco samples. Lemos VA, Novaes CG, Lima Ada S, Vieira DR. J Hazard Mater; 2008 Jun 30; 155(1-2):128-34. PubMed ID: 18155353 [Abstract] [Full Text] [Related] Page: [Next] [New Search]