These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


126 related items for PubMed ID: 18969387

  • 1. Second derivative spectrophotometric method for simultaneous determination of cobalt, nickel and iron using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol.
    Sözgen K, Tütem E.
    Talanta; 2004 Apr 19; 62(5):971-6. PubMed ID: 18969387
    [Abstract] [Full Text] [Related]

  • 2. Simultaneous derivative spectrophotometric determination of cobalt(II) and nickel(II) by dithizone without extraction.
    Oztürk BD, Filik H, Tütem E, Apak R.
    Talanta; 2000 Oct 02; 53(1):263-9. PubMed ID: 18968111
    [Abstract] [Full Text] [Related]

  • 3. Reversed-phase liquid chromatographic simultaneous determination of iron(III) and iron(II) as complexes with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Determination of iron(III) and iron(II) in water samples and ultrasound field effect on distribution of iron(III) and iron(II) in micellar solution.
    Oszwałdowski S, Pikus A.
    Talanta; 2002 Oct 16; 58(4):773-83. PubMed ID: 18968807
    [Abstract] [Full Text] [Related]

  • 4. Simultaneous determination of Fe(III) and Al(III) by first-derivative spectrophotometry and partial least-squares (PLS-2) method - application to post-haemodialysis fluids.
    Aguerssif N, Benamor M, Kachbi M, Draa MT.
    J Trace Elem Med Biol; 2008 Oct 16; 22(3):175-82. PubMed ID: 18755392
    [Abstract] [Full Text] [Related]

  • 5. Simultaneous determination of Mn(II), Cu(II) and Fe(III) as 2-(5'-bromo-2'-pyridylazo)-5-diethylaminophenol complexes by adsorptive cathodic stripping voltammetry at a carbon paste electrode.
    Ghoneim EM.
    Talanta; 2010 Jul 15; 82(2):646-52. PubMed ID: 20602949
    [Abstract] [Full Text] [Related]

  • 6. Derivative spectrophotometric determination of nickel using Br-PADAP.
    Ferreira SL, Costa AC, de Jesus DS.
    Talanta; 1996 Oct 15; 43(10):1649-56. PubMed ID: 18966648
    [Abstract] [Full Text] [Related]

  • 7. Simultaneous spectrophotometric determination of iron, nickel and cobalt in micellar media by using direct orthogonal signal correction-partial least squares method.
    Zarei K, Atabati M, Malekshabani Z.
    Anal Chim Acta; 2006 Jan 18; 556(1):247-54. PubMed ID: 17723355
    [Abstract] [Full Text] [Related]

  • 8. Column preconcentration and FAAS determination of copper, iron, nickel and zinc using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol-tetraphenylborate-naphthalene adsorbent.
    Pancras JP, Puri BK.
    Anal Bioanal Chem; 2002 Dec 18; 374(7-8):1306-11. PubMed ID: 12474102
    [Abstract] [Full Text] [Related]

  • 9. Ammonium tetraphenylborate-naphthalene adsorbent for the preconcentration and trace determination of iron in alloys and biological samples using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol by third derivative spectrophotometry.
    Ali Taher M, Krishan Puri B.
    Talanta; 1996 Feb 18; 43(2):247-53. PubMed ID: 18966485
    [Abstract] [Full Text] [Related]

  • 10. Fiber optic-linear array detection spectrophotometry in combination with cloud point extraction for simultaneous preconcentration and determination of cobalt and nickel.
    Shokoufi N, Shemirani F, Memarzadeh F.
    Anal Chim Acta; 2007 Oct 10; 601(2):204-11. PubMed ID: 17920393
    [Abstract] [Full Text] [Related]

  • 11. Preconcentration of trace cobalt with the ion pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and tetraphenylborate onto microcrystalline naphthalene or column method and its determination by derivative spectrophotometry.
    Pancras JP, Puri BK, Taher MA, Dehzoei AM, Sheibani A.
    Talanta; 1998 Aug 10; 46(5):1107-13. PubMed ID: 18967235
    [Abstract] [Full Text] [Related]

  • 12. H-point standard addition method for simultaneous spectrophotometric determination of Co(II) and Ni(II) by 1-(2-pyridylazo)2-naphthol in micellar media.
    Afkhami A, Bahram M.
    Spectrochim Acta A Mol Biomol Spectrosc; 2004 Jan 10; 60(1-2):181-6. PubMed ID: 14670476
    [Abstract] [Full Text] [Related]

  • 13. Development of an optical chemical sensor based on 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol in Nafion for determination of nickel ion.
    Amini MK, Momeni-Isfahani T, Khorasani JH, Pourhossein M.
    Talanta; 2004 Jun 17; 63(3):713-20. PubMed ID: 18969491
    [Abstract] [Full Text] [Related]

  • 14. Successive ratio-derivative spectra as a new spectrophotometric method for the analysis of ternary mixtures.
    Afkhami A, Bahram M.
    Spectrochim Acta A Mol Biomol Spectrosc; 2005 Mar 17; 61(5):869-77. PubMed ID: 15683791
    [Abstract] [Full Text] [Related]

  • 15. Simultaneous determination of cobalt, nickel and palladium in micellar media using partial least square regression and direct orthogonal signal correction.
    Arab Chamjangali M, Bagherian G, Azizi G.
    Spectrochim Acta A Mol Biomol Spectrosc; 2005 Nov 17; 62(1-3):189-96. PubMed ID: 16257713
    [Abstract] [Full Text] [Related]

  • 16. Simultaneous spectrophotometric determination of La, Ho, Mn 5-Br-PADAP complexes using multivariate calibration with partial least-squares (PLS) data evaluation.
    Ferreyra RE, Camiña JM, Marchevsky E, Luco JM.
    Fresenius J Anal Chem; 2000 Nov 17; 368(6):595-600. PubMed ID: 11228709
    [Abstract] [Full Text] [Related]

  • 17. H-point standard addition method for simultaneous determination of Fe(II), Co(II) and Cu(II) in micellar media with simultaneous addition of three analytes.
    Hasani M, Yaghoubi L, Abdollahi H.
    Talanta; 2006 Feb 28; 68(5):1528-35. PubMed ID: 18970495
    [Abstract] [Full Text] [Related]

  • 18. Atmospheric pressure chemical ionization mass spectrometric and visible spectrophotometric studies of copper(I) and copper(II) complexes with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol.
    Oszwałdowski S, Witowska J, Jarosz M.
    J Mass Spectrom; 2001 Nov 28; 36(11):1230-6. PubMed ID: 11747120
    [Abstract] [Full Text] [Related]

  • 19. [Simultaneous determination of iron, copper and cobalt in food samples by diode array detection-flow injection analysis using partial least squares calibration model].
    Mi JP, Li YQ, Zou XL, Zheng B, Yang JG.
    Guang Pu Xue Yu Guang Pu Fen Xi; 2007 Jun 28; 27(6):1188-91. PubMed ID: 17763789
    [Abstract] [Full Text] [Related]

  • 20. Simultaneous derivative spectrophotometric determination of zinc and cadmium with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in the presence of cetylpyridinium chloride.
    Agnihotri NK, Ratnani S, Singh VK, Singh HB.
    Anal Sci; 2004 Jun 28; 20(6):955-9. PubMed ID: 15228118
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.