These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Slow gantry rotation acquisition technique for on-board four-dimensional digital tomosynthesis. Maurer J, Pan T, Yin FF. Med Phys; 2010 Feb; 37(2):921-33. PubMed ID: 20229901 [Abstract] [Full Text] [Related]
4. On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. Rit S, Wolthaus JW, van Herk M, Sonke JJ. Med Phys; 2009 Jun; 36(6):2283-96. PubMed ID: 19610317 [Abstract] [Full Text] [Related]
8. Real-time respiratory triggered four dimensional cone-beam CT halves imaging dose compared to conventional 4D CBCT. Cooper BJ, O'Brien RT, Shieh CC, Keall PJ. Phys Med Biol; 2019 Mar 27; 64(7):07NT01. PubMed ID: 30754038 [Abstract] [Full Text] [Related]
9. A pilot evaluation of a 4-dimensional cone-beam computed tomographic scheme based on simultaneous motion estimation and image reconstruction. Dang J, Gu X, Pan T, Wang J. Int J Radiat Oncol Biol Phys; 2015 Feb 01; 91(2):410-8. PubMed ID: 25636763 [Abstract] [Full Text] [Related]
10. Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy. Ahmad M, Balter P, Pan T. Med Phys; 2011 Oct 01; 38(10):5646-56. PubMed ID: 21992381 [Abstract] [Full Text] [Related]
13. Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model. Zhang Q, Hu YC, Liu F, Goodman K, Rosenzweig KE, Mageras GS. Med Phys; 2010 Jun 01; 37(6):2901-9. PubMed ID: 20632601 [Abstract] [Full Text] [Related]
14. Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method. Jia X, Tian Z, Lou Y, Sonke JJ, Jiang SB. Med Phys; 2012 Sep 01; 39(9):5592-602. PubMed ID: 22957625 [Abstract] [Full Text] [Related]
17. Impact of motion velocity on four-dimensional target volumes: a phantom study. Nakamura M, Narita Y, Sawada A, Matsugi K, Nakata M, Matsuo Y, Mizowaki T, Hiraoka M. Med Phys; 2009 May 01; 36(5):1610-7. PubMed ID: 19544777 [Abstract] [Full Text] [Related]
18. Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy. Brehm M, Paysan P, Oelhafen M, Kunz P, Kachelrieß M. Med Phys; 2012 Dec 01; 39(12):7603-18. PubMed ID: 23231308 [Abstract] [Full Text] [Related]
19. Volume-of-interest cone-beam CT using a 2.35 MV beam generated with a carbon target. Robar JL, Parsons D, Berman A, Macdonald A. Med Phys; 2012 Jul 01; 39(7):4209-18. PubMed ID: 22830754 [Abstract] [Full Text] [Related]
20. Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction. Zhang H, Kruis M, Sonke JJ. Phys Med Biol; 2017 Mar 21; 62(6):2254-2275. PubMed ID: 28140361 [Abstract] [Full Text] [Related] Page: [Next] [New Search]