These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1303 related items for PubMed ID: 19027256
1. Real-time on-line blend uniformity monitoring using near-infrared reflectance spectrometry: a noninvasive off-line calibration approach. Sulub Y, Wabuyele B, Gargiulo P, Pazdan J, Cheney J, Berry J, Gupta A, Shah R, Wu H, Khan M. J Pharm Biomed Anal; 2009 Jan 15; 49(1):48-54. PubMed ID: 19027256 [Abstract] [Full Text] [Related]
2. Blend uniformity end-point determination using near-infrared spectroscopy and multivariate calibration. Sulub Y, Konigsberger M, Cheney J. J Pharm Biomed Anal; 2011 Jun 01; 55(3):429-34. PubMed ID: 21398064 [Abstract] [Full Text] [Related]
3. Assessment of powder blend uniformity: Comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging. Bakri B, Weimer M, Hauck G, Reich G. Eur J Pharm Biopharm; 2015 Nov 01; 97(Pt A):78-89. PubMed ID: 26455421 [Abstract] [Full Text] [Related]
4. Content uniformity determination of pharmaceutical tablets using five near-infrared reflectance spectrometers: a process analytical technology (PAT) approach using robust multivariate calibration transfer algorithms. Sulub Y, LoBrutto R, Vivilecchia R, Wabuyele BW. Anal Chim Acta; 2008 Mar 24; 611(2):143-50. PubMed ID: 18328314 [Abstract] [Full Text] [Related]
5. Cohesive, multicomponent, dense powder flow characterization by NIR. Benedetti C, Abatzoglou N, Simard JS, McDermott L, Léonard G, Cartilier L. Int J Pharm; 2007 May 24; 336(2):292-301. PubMed ID: 17240094 [Abstract] [Full Text] [Related]
6. Application of process analytical technology in tablet process development using NIR spectroscopy: blend uniformity, content uniformity and coating thickness measurements. Moes JJ, Ruijken MM, Gout E, Frijlink HW, Ugwoke MI. Int J Pharm; 2008 Jun 05; 357(1-2):108-18. PubMed ID: 18394831 [Abstract] [Full Text] [Related]
7. Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe. Li W, Johnson MC, Bruce R, Ulrich S, Rasmussen H, Worosila GD. Int J Pharm; 2006 Dec 01; 326(1-2):182-5. PubMed ID: 16920283 [Abstract] [Full Text] [Related]
8. Near InfraRed Spectroscopy homogeneity evaluation of complex powder blends in a small-scale pharmaceutical preformulation process, a real-life application. Storme-Paris I, Clarot I, Esposito S, Chaumeil JC, Nicolas A, Brion F, Rieutord A, Chaminade P. Eur J Pharm Biopharm; 2009 May 01; 72(1):189-98. PubMed ID: 19059338 [Abstract] [Full Text] [Related]
9. Near-infrared chemical imaging (NIR-CI) on pharmaceutical solid dosage forms-comparing common calibration approaches. Ravn C, Skibsted E, Bro R. J Pharm Biomed Anal; 2008 Nov 04; 48(3):554-61. PubMed ID: 18774667 [Abstract] [Full Text] [Related]
10. Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond. Shi Z, Cogdill RP, Short SM, Anderson CA. J Pharm Biomed Anal; 2008 Aug 05; 47(4-5):738-45. PubMed ID: 18486399 [Abstract] [Full Text] [Related]
11. Evaluation of transmission and reflection modalities for measuring content uniformity of pharmaceutical tablets with near-infrared spectroscopy. Xiang D, LoBrutto R, Cheney J, Wabuyele BW, Berry J, Lyon R, Wu H, Khan MA, Hussain AS. Appl Spectrosc; 2009 Jan 05; 63(1):33-47. PubMed ID: 19146717 [Abstract] [Full Text] [Related]
12. Development of robust quantitative methods by near-infrared spectroscopy for rapid pharmaceutical determination of content uniformity in complex tablet matrix. Xiang D, Konigsberger M, Wabuyele B, Hornung K, Cheney J. Analyst; 2009 Jul 05; 134(7):1405-15. PubMed ID: 19562209 [Abstract] [Full Text] [Related]
13. Applications of NIR in early stage formulation development. Part I. Semi-quantitative blend uniformity and content uniformity analyses by reflectance NIR without calibration models. Li W, Bashai-Woldu A, Ballard J, Johnson M, Agresta M, Rasmussen H, Hu S, Cunningham J, Winstead D. Int J Pharm; 2007 Aug 01; 340(1-2):97-103. PubMed ID: 17467204 [Abstract] [Full Text] [Related]
14. Development of a method for the determination of caffeine anhydrate in various designed intact tablets [correction of tables] by near-infrared spectroscopy: a comparison between reflectance and transmittance technique. Ito M, Suzuki T, Yada S, Kusai A, Nakagami H, Yonemochi E, Terada K. J Pharm Biomed Anal; 2008 Aug 05; 47(4-5):819-27. PubMed ID: 18508223 [Abstract] [Full Text] [Related]
15. Acetaminophen determination in low-dose pharmaceutical syrup by NIR spectroscopy. Ziémons E, Mantanus J, Lebrun P, Rozet E, Evrard B, Hubert P. J Pharm Biomed Anal; 2010 Nov 02; 53(3):510-6. PubMed ID: 20609544 [Abstract] [Full Text] [Related]
16. In-line quantification of drug and excipients in cohesive powder blends by near infrared spectroscopy. Liew CV, Karande AD, Heng PW. Int J Pharm; 2010 Feb 15; 386(1-2):138-48. PubMed ID: 19922776 [Abstract] [Full Text] [Related]
17. The effect of beam size on real-time determination of powder blend homogeneity by an online near infrared sensor. Li W, Johnson MC, Bruce R, Rasmussen H, Worosila GD. J Pharm Biomed Anal; 2007 Jan 17; 43(2):711-7. PubMed ID: 16908115 [Abstract] [Full Text] [Related]
18. Improving prediction selectivity for on-line near-infrared monitoring of components in etchant solution by spectral range optimization. Namkung H, Lee Y, Chung H. Anal Chim Acta; 2008 Jan 07; 606(1):50-6. PubMed ID: 18068770 [Abstract] [Full Text] [Related]
19. Building the quality into pellet manufacturing environment--feasibility study and validation of an in-line quantitative near infrared (NIR) method. Mantanus J, Ziémons E, Rozet E, Streel B, Klinkenberg R, Evrard B, Rantanen J, Hubert P. Talanta; 2010 Dec 15; 83(2):305-11. PubMed ID: 21111138 [Abstract] [Full Text] [Related]
20. The use of NIR as a multi-parametric in situ monitoring technique in filamentous fermentation systems. Rodrigues LO, Vieira L, Cardoso JP, Menezes JC. Talanta; 2008 Jun 15; 75(5):1356-61. PubMed ID: 18585224 [Abstract] [Full Text] [Related] Page: [Next] [New Search]