These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
752 related items for PubMed ID: 19109848
1. Subnormothermic machine perfusion protects steatotic livers against preservation injury: a potential for donor pool increase? Vairetti M, Ferrigno A, Carlucci F, Tabucchi A, Rizzo V, Boncompagni E, Neri D, Gringeri E, Freitas I, Cillo U. Liver Transpl; 2009 Jan; 15(1):20-9. PubMed ID: 19109848 [Abstract] [Full Text] [Related]
2. Machine perfusion at 20°C reduces preservation damage to livers from non-heart beating donors. Ferrigno A, Rizzo V, Boncompagni E, Bianchi A, Gringeri E, Neri D, Richelmi P, Freitas I, Cillo U, Vairetti M. Cryobiology; 2011 Apr; 62(2):152-8. PubMed ID: 21315707 [Abstract] [Full Text] [Related]
3. Subnormothermic machine perfusion protects against rat liver preservation injury: a comparative evaluation with conventional cold storage. Vairetti M, Ferrigno A, Rizzo V, Richelmi P, Boncompagni E, Neri D, Freitas I, Cillo U. Transplant Proc; 2007 Apr; 39(6):1765-7. PubMed ID: 17692606 [Abstract] [Full Text] [Related]
4. Different susceptibility of liver grafts from lean and obese Zucker rats to preservation injury. Ferrigno A, Carlucci F, Tabucchi A, Tommassini V, Rizzo V, Richelmi P, Gringeri E, Neri D, Boncompagni E, Freitas I, Cillo U, Vairetti M. Cryobiology; 2009 Dec; 59(3):327-34. PubMed ID: 19766103 [Abstract] [Full Text] [Related]
5. Preservation of steatotic livers: a comparison between cold storage and machine perfusion preservation. Bessems M, Doorschodt BM, Kolkert JL, Vetelainen RL, van Vliet AK, Vreeling H, van Marle J, van Gulik TM. Liver Transpl; 2007 Apr; 13(4):497-504. PubMed ID: 17394146 [Abstract] [Full Text] [Related]
6. Preservation of steatotic livers in IGL-1 solution. Ben Mosbah I, Roselló-Catafau J, Franco-Gou R, Abdennebi HB, Saidane D, Ramella-Virieux S, Boillot O, Peralta C. Liver Transpl; 2006 Aug; 12(8):1215-23. PubMed ID: 16724331 [Abstract] [Full Text] [Related]
7. Correlation between the liver temperature employed during machine perfusion and reperfusion damage: role of Ca2+. Vairetti M, Ferrigno A, Rizzo V, Boncompagni E, Carraro A, Gringeri E, Milanesi G, Barni S, Freitas I, Cillo U. Liver Transpl; 2008 Apr; 14(4):494-503. PubMed ID: 18383108 [Abstract] [Full Text] [Related]
8. Addition of carvedilol to University Wisconsin solution improves rat steatotic and nonsteatotic liver preservation. Ben Mosbah I, Roselló-Catafau J, Alfany-Fernandez I, Rimola A, Parellada PP, Mitjavila MT, Lojek A, Ben Abdennebi H, Boillot O, Rodés J, Peralta C. Liver Transpl; 2010 Feb; 16(2):163-71. PubMed ID: 20104484 [Abstract] [Full Text] [Related]
9. The influence of storage temperature during machine perfusion on preservation quality of marginal donor livers. Olschewski P, Gass P, Ariyakhagorn V, Jasse K, Hunold G, Menzel M, Schöning W, Schmitz V, Neuhaus P, Puhl G. Cryobiology; 2010 Jun; 60(3):337-43. PubMed ID: 20233587 [Abstract] [Full Text] [Related]
10. The effects of N-acetylcysteine and anti-intercellular adhesion molecule-1 monoclonal antibody against ischemia-reperfusion injury of the rat steatotic liver produced by a choline-methionine-deficient diet. Nakano H, Nagasaki H, Barama A, Boudjema K, Jaeck D, Kumada K, Tatsuno M, Baek Y, Kitamura N, Suzuki T, Yamaguchi M. Hepatology; 1997 Sep; 26(3):670-8. PubMed ID: 9303498 [Abstract] [Full Text] [Related]
11. Improved rat liver preservation by hypothermic continuous machine perfusion using polysol, a new, enriched preservation solution. Bessems M, Doorschodt BM, van Vliet AK, van Gulik TM. Liver Transpl; 2005 May; 11(5):539-46. PubMed ID: 15838888 [Abstract] [Full Text] [Related]
12. Improved machine perfusion preservation of the non-heart-beating donor rat liver using Polysol: a new machine perfusion preservation solution. Bessems M, Doorschodt BM, van Marle J, Vreeling H, Meijer AJ, van Gulik TM. Liver Transpl; 2005 Nov; 11(11):1379-88. PubMed ID: 16237689 [Abstract] [Full Text] [Related]
13. Impact of polysol, a newly developed preservation solution, on cold storage of steatotic rat livers. Hata K, Tolba RH, Wei L, Doorschodt BM, Büttner R, Yamamoto Y, Minor T. Liver Transpl; 2007 Jan; 13(1):114-21. PubMed ID: 17117434 [Abstract] [Full Text] [Related]
14. Melatonin protects steatotic and nonsteatotic liver grafts against cold ischemia and reperfusion injury. Zaoualí MA, Reiter RJ, Padrissa-Altés S, Boncompagni E, García JJ, Ben Abnennebi H, Freitas I, García-Gil FA, Rosello-Catafau J. J Pineal Res; 2011 Mar; 50(2):213-21. PubMed ID: 21108657 [Abstract] [Full Text] [Related]
15. Survival transplantation of preserved non-heart-beating donor rat livers: preservation by hypothermic machine perfusion. Lee CY, Jain S, Duncan HM, Zhang JX, Jones JW, Southard JH, Clemens MG. Transplantation; 2003 Nov 27; 76(10):1432-6. PubMed ID: 14657681 [Abstract] [Full Text] [Related]
16. Machine perfusion preservation of the pig liver using a new preservation solution, polysol. Bessems M, Doorschodt BM, Dinant S, de Graaf W, van Gulik TM. Transplant Proc; 2006 Jun 27; 38(5):1238-42. PubMed ID: 16797272 [Abstract] [Full Text] [Related]
17. L-carnitine ameliorates abnormal vulnerability of steatotic rat livers to cold ischemic preservation. Tolba RH, Pütz U, Decker D, Dombrowski F, Lauschke H. Transplantation; 2003 Dec 27; 76(12):1681-6. PubMed ID: 14688515 [Abstract] [Full Text] [Related]
18. Role of perfusion medium, oxygen and rheology for endoplasmic reticulum stress-induced cell death after hypothermic machine preservation of the liver. Manekeller S, Schuppius A, Stegemann J, Hirner A, Minor T. Transpl Int; 2008 Feb 27; 21(2):169-77. PubMed ID: 18005084 [Abstract] [Full Text] [Related]
19. Addition of adenosine monophosphate-activated protein kinase activators to University of Wisconsin solution: a way of protecting rat steatotic livers. Ben Mosbah I, Massip-Salcedo M, Fernández-Monteiro I, Xaus C, Bartrons R, Boillot O, Roselló-Catafau J, Peralta C. Liver Transpl; 2007 Mar 27; 13(3):410-25. PubMed ID: 17326058 [Abstract] [Full Text] [Related]
20. Machine perfusion preservation of the non-heart-beating donor rat livers using polysol, a new preservation solution. Bessems M, Doorschodt BM, van Vliet AK, van Gulik TM. Transplant Proc; 2005 Mar 27; 37(1):326-8. PubMed ID: 15808632 [Abstract] [Full Text] [Related] Page: [Next] [New Search]