These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


92 related items for PubMed ID: 1912092

  • 1. Cholesterol determinations from skin puncture and venous blood have similar imprecisions.
    Dörner K, Dorn-Zachertz D.
    Eur J Clin Chem Clin Biochem; 1991 Jun; 29(6):411-3. PubMed ID: 1912092
    [Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3. [Measurement of blood cholesterol, decentralized, using a Reflotron, or centralized in a laboratory. A comparison].
    Christensen TE, Agner E, Jensen SE, Jacobsen K, Mahnfeldt MS, Baastrup A.
    Ugeskr Laeger; 1990 Nov 05; 152(45):3346-8. PubMed ID: 2238225
    [Abstract] [Full Text] [Related]

  • 4. Adequacies of skin puncture for evaluating biochemical and hematological blood parameters in athletes.
    Nunes LA, Gandra PG, Alves AA, Kubota LT, de Macedo DV.
    Clin J Sport Med; 2006 Sep 05; 16(5):418-21. PubMed ID: 17016119
    [Abstract] [Full Text] [Related]

  • 5. Precision of a dry-chemistry method of lipid screening.
    Bowden RG, Kingery PM, Long L.
    Public Health; 2006 Jun 05; 120(6):572-6. PubMed ID: 16730036
    [Abstract] [Full Text] [Related]

  • 6. Lymphocyte stimulation assay utilizing newborn heel skin puncture blood samples.
    Ruuskanen O, Pittard WB, Sorensen RU, Polmar SH.
    J Clin Lab Immunol; 1980 Sep 05; 4(2):111-4. PubMed ID: 7441711
    [Abstract] [Full Text] [Related]

  • 7. Multicenter evaluation of a patient-administered test for blood cholesterol measurement.
    McNamara JR, Warnick GR, Leary ET, Wittels E, Nelson FE, Pearl MF, Schaefer EJ.
    Prev Med; 1996 Sep 05; 25(5):583-92. PubMed ID: 8888327
    [Abstract] [Full Text] [Related]

  • 8. Arterial sampler filling time during arterial and venous punctures, and its relationship with mean arterial pressure in human subjects.
    Bender JJ, Allison JR, Goehring JJ, Patel MD, Niederst SM, Douce FH.
    Respir Care; 2012 Nov 05; 57(11):1945-8. PubMed ID: 22613803
    [Abstract] [Full Text] [Related]

  • 9. Accuracy of coagulation values obtained from a heparinized central venous catheter.
    Pinto KM.
    Oncol Nurs Forum; 1994 Apr 05; 21(3):573-5. PubMed ID: 8052553
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. [Measurement of cholesterol in capillary blood using the Reflotron system. Results from approximately 1,000 comparisons with reference measurements of cholesterol in venous serum].
    Gerdes LU, Bak AM, Faergeman O.
    Ugeskr Laeger; 1990 Jun 11; 152(24):1739-43. PubMed ID: 2360292
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. How accurately does the Reflotron dry-chemistry system measure plasma total cholesterol levels when used a community-screening device.
    Phillips S, Wyndham L, Shaw J, Walker SF.
    Med J Aust; 1988 Aug 01; 149(3):122-5. PubMed ID: 3398798
    [Abstract] [Full Text] [Related]

  • 15. The Reflotron Total Cholesterol assay in heparinized venous and capillary blood.
    Boerma GJ, Liem TL, Jacobs-de Haas JA, de Jong-van Staveren FA, Verbree W, Eman I.
    J Clin Chem Clin Biochem; 1990 Apr 01; 28(4):255-8. PubMed ID: 2358795
    [Abstract] [Full Text] [Related]

  • 16. Simultaneously obtained skin-puncture serum, skin-puncture plasma, and venous serum compared, and effects of warming the skin before puncture.
    Blumenfeld TA, Hertelendy WG, Ford SH.
    Clin Chem; 1977 Sep 01; 23(9):1705-10. PubMed ID: 890915
    [Abstract] [Full Text] [Related]

  • 17. Lymphocyte subset counts in skin puncture and venous blood compared.
    Cracknell SE, Hinchliffe RF, Lilleyman JS.
    J Clin Pathol; 1995 Dec 01; 48(12):1137-8. PubMed ID: 8568002
    [Abstract] [Full Text] [Related]

  • 18. Blood cholesterol concentration: fingerstick plasma vs venous serum sampling.
    Greenland P, Bowley NL, Meiklejohn B, Doane KL, Sparks CE.
    Clin Chem; 1990 Apr 01; 36(4):628-30. PubMed ID: 2323042
    [Abstract] [Full Text] [Related]

  • 19. Comparison of capillary and venous blood sampling for quantitation of plasma cholesterol.
    Ishikawa TT, Morrison J, Fallat R, Parsons D, Glueck CJ.
    J Lab Clin Med; 1974 Aug 01; 84(2):281-6. PubMed ID: 4843232
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 5.