These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
628 related items for PubMed ID: 19121822
1. Influence of different artificial disc kinematics on spine biomechanics. Zander T, Rohlmann A, Bergmann G. Clin Biomech (Bristol, Avon); 2009 Feb; 24(2):135-42. PubMed ID: 19121822 [Abstract] [Full Text] [Related]
3. In situ contact analysis of the prosthesis components of Prodisc-L in lumbar spine following total disc replacement. Chen WM, Park C, Lee K, Lee S. Spine (Phila Pa 1976); 2009 Sep 15; 34(20):E716-23. PubMed ID: 19752690 [Abstract] [Full Text] [Related]
4. Biomechanical effect of constraint in lumbar total disc replacement: a study with finite element analysis. Chung SK, Kim YE, Wang KC. Spine (Phila Pa 1976); 2009 May 20; 34(12):1281-6. PubMed ID: 19455003 [Abstract] [Full Text] [Related]
5. Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Cunningham BW, Gordon JD, Dmitriev AE, Hu N, McAfee PC. Spine (Phila Pa 1976); 2003 Oct 15; 28(20):S110-7. PubMed ID: 14560182 [Abstract] [Full Text] [Related]
6. Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study. Lin CY, Kang H, Rouleau JP, Hollister SJ, Marca FL. Spine (Phila Pa 1976); 2009 Jul 01; 34(15):1554-60. PubMed ID: 19564765 [Abstract] [Full Text] [Related]
9. Effect of an interspinous implant on loads in the lumbar spine. Rohlmann A, Zander T, Burra NK, Bergmann G. Biomed Tech (Berl); 2005 Oct 01; 50(10):343-7. PubMed ID: 16300050 [Abstract] [Full Text] [Related]
11. Effects of fusion-bone stiffness on the mechanical behavior of the lumbar spine after vertebral body replacement. Rohlmann A, Zander T, Bergmann G. Clin Biomech (Bristol, Avon); 2006 Mar 01; 21(3):221-7. PubMed ID: 16356613 [Abstract] [Full Text] [Related]
12. Internal and external responses of anterior lumbar/lumbosacral fusion: nonlinear finite element analysis. Guan Y, Yoganandan N, Maiman DJ, Pintar FA. J Spinal Disord Tech; 2008 Jun 01; 21(4):299-304. PubMed ID: 18525492 [Abstract] [Full Text] [Related]
18. Biomechanical comparison between lumbar disc arthroplasty and fusion. Chen SH, Zhong ZC, Chen CS, Chen WJ, Hung C. Med Eng Phys; 2009 Mar 01; 31(2):244-53. PubMed ID: 18760654 [Abstract] [Full Text] [Related]
19. Effect of a pedicle-screw-based motion preservation system on lumbar spine biomechanics: a probabilistic finite element study with subsequent sensitivity analysis. Rohlmann A, Nabil Boustani H, Bergmann G, Zander T. J Biomech; 2010 Nov 16; 43(15):2963-9. PubMed ID: 20696430 [Abstract] [Full Text] [Related]