These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


723 related items for PubMed ID: 19133021

  • 1.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 2. Development and characterization of an alginate-impregnated polyester vascular graft.
    Lee JH, Kim WG, Kim SS, Lee JH, Lee HB.
    J Biomed Mater Res; 1997 Aug; 36(2):200-8. PubMed ID: 9261681
    [Abstract] [Full Text] [Related]

  • 3. Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study.
    Izhar U, Schwalb H, Borman JB, Hellener GR, Hotoveli-Salomon A, Marom G, Stern T, Cohn D.
    J Surg Res; 2001 Feb; 95(2):152-60. PubMed ID: 11162039
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Analysis of graft healing in a new elastomer-coated vascular prosthesis.
    Granke K, Ochsner JL, McClugage SG, Zdrahal P.
    Cardiovasc Surg; 1993 Jun; 1(3):254-61. PubMed ID: 8076041
    [Abstract] [Full Text] [Related]

  • 7. Evaluating the Dialine vascular prosthesis knitted from an alternative source of polyester yarns.
    King MW, Marois Y, Guidoin R, Ukpabi P, Deng X, Martin L, Pâris E, Douville Y.
    J Biomed Mater Res; 1995 May; 29(5):595-610. PubMed ID: 7622545
    [Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9. A novel bioengineered small-caliber vascular graft incorporating heparin and sirolimus: excellent 6-month patency.
    Ishii Y, Sakamoto S, Kronengold RT, Virmani R, Rivera EA, Goldman SM, Prechtel EJ, Hill JG, Damiano RJ.
    J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1237-45; discussion 1245-6. PubMed ID: 18544361
    [Abstract] [Full Text] [Related]

  • 10. Biological reaction to small-diameter vascular grafts made of silk fibroin implanted in the abdominal aortae of rats.
    Fukayama T, Takagi K, Tanaka R, Hatakeyama Y, Aytemiz D, Suzuki Y, Asakura T.
    Ann Vasc Surg; 2015 Feb; 29(2):341-52. PubMed ID: 25449988
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. Healing characteristics of polymer-coated or collagen-treated Dacron grafts: an experimental porcine study.
    Pärsson H, Jundzill W, Johansson K, Jonung T, Norgren L.
    Cardiovasc Surg; 1994 Apr; 2(2):242-8. PubMed ID: 8049955
    [Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. A novel three-dimensional tubular scaffold prepared from silk fibroin by electrospinning.
    Zhou J, Cao C, Ma X.
    Int J Biol Macromol; 2009 Dec 01; 45(5):504-10. PubMed ID: 19772871
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Compliant electrospun silk fibroin tubes for small vessel bypass grafting.
    Marelli B, Alessandrino A, Farè S, Freddi G, Mantovani D, Tanzi MC.
    Acta Biomater; 2010 Oct 01; 6(10):4019-26. PubMed ID: 20466080
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 37.