These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


169 related items for PubMed ID: 19202807

  • 1. Determination of trace amounts of zinc by flame atomic absorption spectrometry after preconcentration with modified clinoptilolite zeolite.
    Hajialigol S, Taher MA, Malekpour A.
    J AOAC Int; 2008; 91(6):1446-52. PubMed ID: 19202807
    [Abstract] [Full Text] [Related]

  • 2. Natural analcime zeolite modified with 5-Br-PADAP for the preconcentration and anodic stripping voltammetric determination of trace amount of cadmium.
    Afzali D, Mostafavi A, Taher MA, Rezaeipour E, Khayatzadeh Mahani M.
    Anal Sci; 2005 Apr; 21(4):383-6. PubMed ID: 15844330
    [Abstract] [Full Text] [Related]

  • 3. Flame atomic absorption spectrometric determination of trace amounts of nickel after extraction and preconcentration onto natural modified analcime zeolite loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol.
    Afzali D, Taher MA, Mostafavi A, Mahani MK.
    J AOAC Int; 2005 Apr; 88(3):842-6. PubMed ID: 16001860
    [Abstract] [Full Text] [Related]

  • 4. Determination of trace amounts of vanadium by UV-vis spectrophotometric after separation and preconcentration with modified natural clinoptilolite as a new sorbent.
    Rostampour L, Taher MA.
    Talanta; 2008 Jun 15; 75(5):1279-83. PubMed ID: 18585213
    [Abstract] [Full Text] [Related]

  • 5. Natural analcime zeolite modified with 2,3,5,6-tetra(2-pyridyl)pyrazine for preconcentration and determination of trace amounts of cadmium by flame atomic absorption spectrometry.
    Saljooghi AS, Saljoghi ZS.
    Toxicol Ind Health; 2012 Oct 15; 28(9):771-8. PubMed ID: 22033430
    [Abstract] [Full Text] [Related]

  • 6. Study on solid-phase extraction and flame atomic absorption spectrometry for the selective determination of cadmium in water and plant samples with modified clinoptilolite.
    Malekpour A, Hajialigol S, Taher MA.
    J Hazard Mater; 2009 Dec 15; 172(1):229-33. PubMed ID: 19640644
    [Abstract] [Full Text] [Related]

  • 7. Flame atomic absorption spectrometric determination of trace amounts of manganese in alloys and biological samples after preconcentration with the ion pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and ammonium tetraphenylborate on microcrystalline naphthalene or by column method.
    Taher MA.
    Anal Sci; 2001 Aug 15; 17(8):969-73. PubMed ID: 11708102
    [Abstract] [Full Text] [Related]

  • 8. Atomic absorption spectrometric determination of trace zinc in alloys and biological samples after preconcentration with [1-(2-pyridylazo)-2-naphthol] on microcrystalline naphthalene.
    Taher MA.
    Analyst; 2000 Oct 15; 125(10):1865-8. PubMed ID: 11070556
    [Abstract] [Full Text] [Related]

  • 9. Application of l-cystine modified zeolite for preconcentration and determination of ultra-trace levels of cadmium by flame atomic absorption spectrometry.
    Rezvani SA, Soleymanpour A.
    J Chromatogr A; 2016 Mar 04; 1436():34-41. PubMed ID: 26852265
    [Abstract] [Full Text] [Related]

  • 10. Simultaneous Separation and Preconcentration of Trace Amounts of Cu(II), Ni(II), Zn(II), and Cd(II) with Modified Nanoporous Pumpellyite Zeolite.
    Mohammadi SZ, Shamspur T, Shahsavani E, Fozooni S.
    J AOAC Int; 2015 Mar 04; 98(3):828-833. PubMed ID: 26086263
    [Abstract] [Full Text] [Related]

  • 11. Flame atomic absorption spectrometry determination of trace amount of cobalt (II) after preconcentration using modified analcime zeolite loaded with bis-(2-hydroxy-1-naphthaldimine)-N-diethylene-triamine.
    Shamspur T, Mostafavi A.
    J AOAC Int; 2009 Mar 04; 92(4):1203-7. PubMed ID: 19714991
    [Abstract] [Full Text] [Related]

  • 12. Determination of trace cadmium in waters by flame atomic absorption spectrophotometry after preconcentration with 1-nitroso-2-naphthol-3,6-disulfonic acid on Ambersorb 572.
    Kendüzler E, Türker AR.
    Ann Chim; 2005 Mar 04; 95(1-2):77-85. PubMed ID: 15801179
    [Abstract] [Full Text] [Related]

  • 13. Preconcentration and determination of cadmium by GFAAS after solid-phase extraction with synthetic zeolite.
    Minamisawa H, Okunugi R, Minamisawa M, Tanaka S, Saitoh K, Arai N, Shibukawa M.
    Anal Sci; 2006 May 04; 22(5):709-13. PubMed ID: 16770049
    [Abstract] [Full Text] [Related]

  • 14. Determination of ultra-trace amounts of cadmium by ET-AAS after column preconcentration with a new sorbent of modified MWCNTs.
    Madadizadeh M, Taher MA, Ashkenani H.
    Environ Monit Assess; 2013 May 04; 185(5):4097-105. PubMed ID: 22941187
    [Abstract] [Full Text] [Related]

  • 15. [Determination of trace cadmium in environment water samples by flame atomic absorption spectrometry using flow injection on-line preconcentration with double microcolumns].
    Kang WJ, Liang SX, Jia LH, Xu LQ, Zhao Y, Sun HW.
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 May 04; 25(5):792-5. PubMed ID: 16128092
    [Abstract] [Full Text] [Related]

  • 16. Determination of trace levels of manganese in various biological and environmental samples by atomic absorption spectrometry after solid-liquid extraction and preconcentration with the ion pair formed by the nitroso-S anion and the tetradecyldimethylbenzylammonium cation.
    Taher MA, Dehzoei AM.
    J AOAC Int; 2001 May 04; 84(3):706-12. PubMed ID: 11417635
    [Abstract] [Full Text] [Related]

  • 17. New use of polypyrrole-chloride for selective preconcentration of copper prior to its determination of flame atomic absorption spectrometry.
    Sönmez S, Divrikli U, Elçi L.
    Talanta; 2010 Aug 15; 82(3):939-44. PubMed ID: 20678649
    [Abstract] [Full Text] [Related]

  • 18. Utility of solid-phase spectrophotometry to determine trace amounts of zinc in environmental and biological samples.
    Amin AS.
    Anal Biochem; 2011 Nov 15; 418(2):172-9. PubMed ID: 21820999
    [Abstract] [Full Text] [Related]

  • 19. Determination of trace amounts of lead and manganese in water samples after simultaneous preconcentration onto modified amberlite XAD-4 resin.
    Mobarakeh SZ, Afzali D, Taher MA, Dargahi R.
    J AOAC Int; 2009 Nov 15; 92(5):1576-9. PubMed ID: 19916395
    [Abstract] [Full Text] [Related]

  • 20. Column chromatographic pre-concentration of iron(III) in alloys and biological samples with 1-nitroso-2-naphthol-3,6-disulphonate and benzyldimethyltetradecylammonium-perchlorate adsorbent supported on naphthalene using atomic absorption spectrometry.
    Miura J, Arima S, Satake M.
    Analyst; 1990 Sep 15; 115(9):1191-5. PubMed ID: 2091489
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.