These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


114 related items for PubMed ID: 1926282

  • 1. Particle concentration fluorescence immunoassay of gentamicin.
    Varma-Nelson P, Nelson JE, Belknap SM.
    Ther Drug Monit; 1991 May; 13(3):260-2. PubMed ID: 1926282
    [Abstract] [Full Text] [Related]

  • 2. Comparative evaluation of the Abbott TDX, the Abbott ABA200, and the Syva LAB5000 for assay of serum gentamicin.
    Cheng AF, Lam AW, French GL.
    J Antimicrob Chemother; 1987 Jan; 19(1):127-33. PubMed ID: 3549667
    [Abstract] [Full Text] [Related]

  • 3. Evaluation of Innofluor fluorescence polarization immunoassay kits for the determination of serum concentrations of gentamicin, tobramycin, amikacin and vancomycin.lesassays@ukneqasaa.win-uk.net.
    White LO, Holt HA, Reeves DS, MacGowan AP.
    J Antimicrob Chemother; 1997 Mar; 39(3):355-61. PubMed ID: 9096185
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Flow injection fluorescence immunoassay for gentamicin using sol-gel-derived mesoporous biomaterial.
    Yang HH, Zhu QZ, Qu HY, Chen XL, Ding MT, Xu JG.
    Anal Biochem; 2002 Sep 01; 308(1):71-6. PubMed ID: 12234465
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Performance of a fluorescence polarization immunoassay system evaluated by therapeutic monitoring of four drugs.
    Zaninotto M, Secchiero S, Paleari CD, Burlina A.
    Ther Drug Monit; 1992 Aug 01; 14(4):301-5. PubMed ID: 1519304
    [Abstract] [Full Text] [Related]

  • 9. Evaluation of a novel fluorescence polarization immunoassay for teicoplanin.
    Cox H, Whitby M, Nimmo G, Williams G.
    Antimicrob Agents Chemother; 1993 Sep 01; 37(9):1924-6. PubMed ID: 8239606
    [Abstract] [Full Text] [Related]

  • 10. Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.
    Pohlod DJ, Saravolatz LD, Somerville MM.
    J Clin Microbiol; 1984 Nov 01; 20(5):866-8. PubMed ID: 6392321
    [Abstract] [Full Text] [Related]

  • 11. Serum gentamicin assay: an assessment of two different Syva EMIT and Abbot TDx instruments.
    Seifart HI, van der Bijl P, Brits DA, Kotze TJ.
    J Antimicrob Chemother; 1990 Apr 01; 25(4):665-72. PubMed ID: 2190973
    [Abstract] [Full Text] [Related]

  • 12. A comparison of the homogeneous enzyme immunoassay and polarization fluoroimmunoassay of gentamicin.
    Andrews JM, Wise R.
    J Antimicrob Chemother; 1984 Nov 01; 14(5):509-20. PubMed ID: 6392280
    [Abstract] [Full Text] [Related]

  • 13. Fluorescence polarization immunoassay of gentamicin or netilmicin in blood spotted on filter paper.
    Fujimoto T, Tsuda Y, Tawa R, Hirose S.
    Clin Chem; 1989 May 01; 35(5):867-9. PubMed ID: 2720984
    [Abstract] [Full Text] [Related]

  • 14. Comparison of a fluorescent immunoassay with an enzyme immunoassay and a radioimmunoassay for gentamicin.
    Lau AH, Chow-Tung E.
    Am J Hosp Pharm; 1984 Dec 01; 41(12):2647-50. PubMed ID: 6393760
    [Abstract] [Full Text] [Related]

  • 15. Comparison of the fluorescence polarization immunoassay and the microbiological assay methods for the determination of gentamicin concentration in human serum.
    Tayeb OS, el-Tahawy AT, Islam SI.
    Ther Drug Monit; 1986 Dec 01; 8(2):232-5. PubMed ID: 3726941
    [Abstract] [Full Text] [Related]

  • 16. [Immunological assay of sisomycin by fluorescence polarization].
    Failler JM, Farinotti R, Dauphin A.
    Ann Biol Clin (Paris); 1985 Dec 01; 43(4):341-5. PubMed ID: 4091297
    [Abstract] [Full Text] [Related]

  • 17. Assay of low trough serum gentamicin concentrations by fluorescence polarization immunoassay.
    White LO, MacGowan AP, Lovering AM, Holt HA, Reeves DS, Ryder D.
    J Antimicrob Chemother; 1994 May 01; 33(5):1068-70. PubMed ID: 8089059
    [No Abstract] [Full Text] [Related]

  • 18. Gentamicin substrate-labeled fluorescent immunoassay containing monoclonal antibody.
    Place JD, Thompson SG, Clements HM, Ott RA, Jensen FC.
    Antimicrob Agents Chemother; 1983 Aug 01; 24(2):246-51. PubMed ID: 6357072
    [Abstract] [Full Text] [Related]

  • 19. Comparison of gentamicin pharmacokinetic parameters determined by fluorescence polarization immunoassay and latex agglutination methods.
    Madaras-Kelly KJ, Mihalovic S, Zittel D, Ehresman D, Lakatua DJ, Rotschafer JC.
    Ther Drug Monit; 1994 Aug 01; 16(4):395-9. PubMed ID: 7974630
    [Abstract] [Full Text] [Related]

  • 20. Operator error: a critical determinant of false amikacin and tobramycin concentrations using fluorescence polarization immunoassay kits and TDX analyzer.
    Banerjee SK, Wells A, Dasgupta A.
    Ther Drug Monit; 1999 Oct 01; 21(5):540-3. PubMed ID: 10519452
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.