These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


202 related items for PubMed ID: 19356769

  • 1. Effects of inadequate low-pass filter application.
    García-Niebla J, Serra-Autonell G.
    J Electrocardiol; 2009; 42(4):303-4. PubMed ID: 19356769
    [Abstract] [Full Text] [Related]

  • 2. A wavelet-based adaptive filter for removing ECG interference in EMGdi signals.
    Zhan C, Yeung LF, Yang Z.
    J Electromyogr Kinesiol; 2010 Jun; 20(3):542-9. PubMed ID: 19692270
    [Abstract] [Full Text] [Related]

  • 3. What is inside the electrocardiograph?
    Gregg RE, Zhou SH, Lindauer JM, Helfenbein ED, Giuliano KK.
    J Electrocardiol; 2008 Jun; 41(1):8-14. PubMed ID: 18191652
    [Abstract] [Full Text] [Related]

  • 4. Real time ECG artifact removal for myoelectric prosthesis control.
    Zhou P, Lock B, Kuiken TA.
    Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
    [Abstract] [Full Text] [Related]

  • 5. A simple method to remove ECG artifacts from trunk muscle EMG signals.
    Hof AL.
    J Electromyogr Kinesiol; 2009 Dec; 19(6):e554-5. PubMed ID: 19121951
    [No Abstract] [Full Text] [Related]

  • 6. Power-line interference detection and suppression in ECG signal processing.
    Lin YD, Hu YH.
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):354-7. PubMed ID: 18232382
    [Abstract] [Full Text] [Related]

  • 7. Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators.
    Jekova I, Krasteva V.
    Physiol Meas; 2005 Dec; 26(6):987-1003. PubMed ID: 16311447
    [Abstract] [Full Text] [Related]

  • 8. Effect of ECG filter settings on J-waves.
    Nakagawa M, Tsunemitsu C, Katoh S, Kamiyama Y, Sano N, Ezaki K, Miyazaki H, Teshima Y, Yufu K, Takahashi N, Saikawa T.
    J Electrocardiol; 2014 Dec; 47(1):7-11. PubMed ID: 24369740
    [Abstract] [Full Text] [Related]

  • 9. Application of filtering methods for removal of resuscitation artifacts from human ECG signals.
    Markovsky I, Amann A, Van Huffel S.
    Annu Int Conf IEEE Eng Med Biol Soc; 2008 Dec; 2008():13-6. PubMed ID: 19162582
    [Abstract] [Full Text] [Related]

  • 10. Low-pass differentiators for biological signals with known spectra: application to ECG signal processing.
    Laguna P, Thakor NV, Caminal P, Jańe R.
    IEEE Trans Biomed Eng; 1990 Apr; 37(4):420-5. PubMed ID: 2338356
    [Abstract] [Full Text] [Related]

  • 11. Fast time-varying linear filters for suppression of baseline drift in electrocardiographic signals.
    Kozumplík J, Provazník I.
    Biomed Eng Online; 2017 Feb 07; 16(1):24. PubMed ID: 28173809
    [Abstract] [Full Text] [Related]

  • 12. Basic aspects concerning the event-synchronous interference canceller.
    Ungureanu M, Wolf WM.
    IEEE Trans Biomed Eng; 2006 Nov 07; 53(11):2240-7. PubMed ID: 17073329
    [Abstract] [Full Text] [Related]

  • 13. Removal of baseline wandering in ECG signal by improved detrending method.
    Shin SW, Kim KS, Song CG, Lee JW, Kim JH, Jeung GW.
    Biomed Mater Eng; 2015 Nov 07; 26 Suppl 1():S1087-93. PubMed ID: 26405865
    [Abstract] [Full Text] [Related]

  • 14. Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals.
    Rheinberger K, Steinberger T, Unterkofler K, Baubin M, Klotz A, Amann A.
    IEEE Trans Biomed Eng; 2008 Jan 07; 55(1):130-7. PubMed ID: 18232354
    [Abstract] [Full Text] [Related]

  • 15. Pseudo pacemaker stimuli.
    Smelley MP, Childers R, Knight BP.
    Pacing Clin Electrophysiol; 2008 Apr 07; 31(4):513-6. PubMed ID: 18373775
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms.
    Xu L, Zhang D, Wang K.
    IEEE Trans Biomed Eng; 2005 Nov 07; 52(11):1973-5. PubMed ID: 16285403
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. ECG denoising and compression using a modified extended Kalman filter structure.
    Sayadi O, Shamsollahi MB.
    IEEE Trans Biomed Eng; 2008 Sep 07; 55(9):2240-8. PubMed ID: 18713693
    [Abstract] [Full Text] [Related]

  • 20. Early experience with a novel ambulatory monitor.
    Russell JK, Gehman S.
    J Electrocardiol; 2007 Sep 07; 40(6 Suppl):S160-4. PubMed ID: 17993315
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]