These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Impact of Pulsatility and Flow Rates on Hemodynamic Energy Transmission in an Adult Extracorporeal Life Support System. Wolfe R, Strother A, Wang S, Kunselman AR, Ündar A. Artif Organs; 2015 Jul; 39(7):E127-37. PubMed ID: 25894993 [Abstract] [Full Text] [Related]
7. Hemodynamic energy delivery of the pulsatile flow in a simulated pediatric extracorporeal circuit. Wang S, Haines N, Undar A. ASAIO J; 2009 Jul; 55(1):96-9. PubMed ID: 19092666 [Abstract] [Full Text] [Related]
8. Quantification of perfusion modes in terms of surplus hemodynamic energy levels in a simulated pediatric CPB model. Undar A, Ji B, Lukic B, Zapanta CM, Kunselman AR, Reibson JD, Weiss WJ, Rosenberg G, Myers JL. ASAIO J; 2006 Jul; 52(6):712-7. PubMed ID: 17117064 [Abstract] [Full Text] [Related]
9. Evaluation of conventional nonpulsatile and novel pulsatile extracorporeal life support systems in a simulated pediatric extracorporeal life support model. Wang S, Evenson A, Chin BJ, Kunselman AR, Ündar A. Artif Organs; 2015 Jan; 39(1):E1-9. PubMed ID: 24660832 [Abstract] [Full Text] [Related]
11. A hemodynamic evaluation of the Medos Deltastream DP1 rotary pump and Jostra HL-20 roller pump under pulsatile and nonpulsatile perfusion in an infant cardiopulmonary bypass model--a pilot study. Rider AR, Griffith K, Ressler N, Kunselman AR, Wang S, Undar A. ASAIO J; 2008 Jan; 54(5):529-33. PubMed ID: 18812747 [Abstract] [Full Text] [Related]
15. In vitro performance analysis of a novel pulsatile diagonal pump in a simulated pediatric mechanical circulatory support system. Wang S, Kunselman AR, Ündar A. Artif Organs; 2014 Jan; 38(1):64-72. PubMed ID: 24237183 [Abstract] [Full Text] [Related]
16. Impact of oxygenator selection on hemodynamic energy indicators under pulsatile and nonpulsatile flow in a neonatal extracorporeal life support model. Vasavada R, Khan S, Qiu F, Kunselman A, Undar A. Artif Organs; 2011 Jun; 35(6):E101-7. PubMed ID: 21623841 [Abstract] [Full Text] [Related]
17. Impact of Pulsatile Flow Settings on Hemodynamic Energy Levels Using the Novel Diagonal Medos DP3 Pump in a Simulated Pediatric Extracorporeal Life Support System. Adedayo P, Wang S, Kunselman AR, Ündar A. World J Pediatr Congenit Heart Surg; 2014 Jul; 5(3):440-8. PubMed ID: 24958048 [Abstract] [Full Text] [Related]
19. Impact of tubing length on hemodynamics in a simulated neonatal extracorporeal life support circuit. Qiu F, Uluer MC, Kunselman A, Clark JB, Myers JL, Undar A. Artif Organs; 2010 Nov; 34(11):1003-9. PubMed ID: 21092043 [Abstract] [Full Text] [Related]