21. A comparison of stability of chemical analytes in plasma from the BD Vacutainer® Barricor™ tube with mechanical separator versus tubes containing gel separator. Gawria G, Tillmar L, Landberg E. J Clin Lab Anal; 2020 Feb; 34(2):e23060. PubMed ID: 31605419 [Abstract] [Full Text] [Related]
22. A determination of the pre-analytical storage conditions for insulin like growth factor-I and type III procollagen peptide. Holt RI, Erotokritou-Mulligan I, Ridley SA, McHugh CM, Bassett EE, Cowan DA, Bartlett C, Sönksen PH. Growth Horm IGF Res; 2009 Feb; 19(1):43-50. PubMed ID: 18617430 [Abstract] [Full Text] [Related]
23. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis. Bonetti G, Carta M, Montagnana M, Lo Cascio C, Bonfigli AR, Mosca A, Testa R, Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus. Biochem Med (Zagreb); 2016 Feb; 26(1):68-76. PubMed ID: 26981020 [Abstract] [Full Text] [Related]
24. Solution densities and estimated total protein contents associated with inappropriate flotation of separator gel in different blood collection tubes. Faught RC, Marshall J, Bornhorst J. Arch Pathol Lab Med; 2011 Sep; 135(9):1081-4. PubMed ID: 21877989 [Abstract] [Full Text] [Related]
25. Limited preanalytical requirements for insulin measurement. Vogeser M, Parhofer KG. Clin Biochem; 2005 Jun; 38(6):572-5. PubMed ID: 15885238 [Abstract] [Full Text] [Related]
26. Electrolyte measurement in goats: Comparison of 2 blood gas analyzers and evaluation of the preanalytical blood sample preparation on measurement results. Luethy D, Hopster K. Tierarztl Prax Ausg G Grosstiere Nutztiere; 2020 Jun; 48(3):148-155. PubMed ID: 32557512 [Abstract] [Full Text] [Related]
29. [The ionized calcium fraction of the blood: dependence on different methodical factors]. Kölling K. Zentralbl Veterinarmed A; 1991 Oct; 38(8):629-38. PubMed ID: 1771985 [Abstract] [Full Text] [Related]
30. Heparin interference in whole blood sodium measurements in a pediatric setting. Yip PM, Chan MK, Zielinski N, Adeli K. Clin Biochem; 2006 Apr; 39(4):391-5. PubMed ID: 16443209 [Abstract] [Full Text] [Related]
31. Changes in canine ionised calcium under three storage conditions. Brennan SF, O'donovan J, Mooney CT. J Small Anim Pract; 2006 Jul; 47(7):383-6. PubMed ID: 16842274 [Abstract] [Full Text] [Related]
32. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes. Lippi G, Salvagno GL, Lampus S, Danese E, Gelati M, Bovo C, Montagnana M, Simundic AM. Clin Chem Lab Med; 2018 Nov 27; 56(12):2125-2131. PubMed ID: 29935113 [Abstract] [Full Text] [Related]
33. Comparison of glucose determinations on blood samples collected in three types of tubes. Li G, Cabanero M, Wang Z, Wang H, Huang T, Alexis H, Eid I, Muth G, Pincus MR. Ann Clin Lab Sci; 2013 Nov 27; 43(3):278-84. PubMed ID: 23884222 [Abstract] [Full Text] [Related]
34. Sample stability and heparin interference in ionized calcium and ionized magnesium measurements in horses using the Stat Profile Prime Plus co-oximetry electrolyte analyzer. Sanmartí J, Robles-Guirado JA, Jose-Cunilleras E, Bassols A. Vet Clin Pathol; 2023 Jun 27; 52(2):252-260. PubMed ID: 36746672 [Abstract] [Full Text] [Related]
35. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube. Arslan FD, Karakoyun I, Basok BI, Aksit MZ, Baysoy A, Ozturk YK, Guclu YA, Duman C. Biochem Med (Zagreb); 2017 Oct 15; 27(3):030706. PubMed ID: 28900369 [Abstract] [Full Text] [Related]
36. Preanalytical procedures in the measurement of ionized calcium in serum and plasma. Kallner A. Eur J Clin Chem Clin Biochem; 1996 Jan 15; 34(1):53-8. PubMed ID: 8704036 [Abstract] [Full Text] [Related]
37. Stability of Routine Biochemical Analytes in Whole Blood and Plasma From Lithium Heparin Gel Tubes During 6-hr Storage. Monneret D, Godmer A, Le Guen R, Bravetti C, Emeraud C, Marteau A, Alkouri R, Mestari F, Dever S, Imbert-Bismut F, Bonnefont-Rousselot D. J Clin Lab Anal; 2016 Sep 15; 30(5):602-9. PubMed ID: 26891785 [Abstract] [Full Text] [Related]
38. Different manufacturers of syringes: a new source of variability in blood gas, acid-base balance and related laboratory test? Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Clin Biochem; 2012 Jun 15; 45(9):683-7. PubMed ID: 22440459 [Abstract] [Full Text] [Related]
39. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample. Lippi G, Salvagno GL, Adcock DM, Gelati M, Guidi GC, Favaloro EJ. Int J Lab Hematol; 2010 Feb 15; 32(1 Pt 2):132-8. PubMed ID: 19220524 [Abstract] [Full Text] [Related]
40. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase. Lippi G, Avanzini P, Cosmai M, Aloe R, Ernst D. Br J Biomed Sci; 2012 Feb 15; 69(2):67-70. PubMed ID: 22872930 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]