These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1769 related items for PubMed ID: 19414489
1. Computational fluid dynamics simulation of transcatheter aortic valve degeneration. Dwyer HA, Matthews PB, Azadani A, Jaussaud N, Ge L, Guy TS, Tseng EE. Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489 [Abstract] [Full Text] [Related]
2. Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency. Dwyer HA, Matthews PB, Azadani A, Ge L, Guy TS, Tseng EE. J Thorac Cardiovasc Surg; 2009 Nov; 138(5):1227-33. PubMed ID: 19748632 [Abstract] [Full Text] [Related]
3. Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease. Chandra S, Rajamannan NM, Sucosky P. Biomech Model Mechanobiol; 2012 Sep; 11(7):1085-96. PubMed ID: 22294208 [Abstract] [Full Text] [Related]
4. Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. Sun W, Li K, Sirois E. J Biomech; 2010 Dec 01; 43(16):3085-90. PubMed ID: 20817163 [Abstract] [Full Text] [Related]
5. Age-related changes in the aortic valve affect leaflet stress distributions: implications for aortic valve degeneration. Singh R, Strom JA, Ondrovic L, Joseph B, VanAuker MD. J Heart Valve Dis; 2008 May 01; 17(3):290-8; discussion 299. PubMed ID: 18592926 [Abstract] [Full Text] [Related]
6. Aortic valve-in-valve implantation: impact of transcatheter- bioprosthesis size mismatch. Azadani AN, Jaussaud N, Matthews PB, Chuter TA, Ge L, Guy TS, Guccione J, Tseng EE. J Heart Valve Dis; 2009 Jul 01; 18(4):367-73. PubMed ID: 19852139 [Abstract] [Full Text] [Related]
7. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. Abbasi M, Azadani AN. J Biomech; 2015 Oct 15; 48(13):3663-71. PubMed ID: 26338100 [Abstract] [Full Text] [Related]
8. Stent and Leaflet Stresses in 29-mm Second-Generation Balloon-Expandable Transcatheter Aortic Valve. Xuan Y, Krishnan K, Ye J, Dvir D, Guccione JM, Ge L, Tseng EE. Ann Thorac Surg; 2017 Sep 15; 104(3):773-781. PubMed ID: 28410636 [Abstract] [Full Text] [Related]
9. Hemodynamics of the Edwards Sapien XT transcatheter heart valve in noncircular aortic annuli. Scharfschwerdt M, Meyer-Saraei R, Schmidtke C, Sievers HH. J Thorac Cardiovasc Surg; 2014 Jul 15; 148(1):126-32. PubMed ID: 24071472 [Abstract] [Full Text] [Related]
10. Blood Stasis on Transcatheter Valve Leaflets and Implications for Valve-in-Valve Leaflet Thrombosis. Vahidkhah K, Javani S, Abbasi M, Azadani PN, Tandar A, Dvir D, Azadani AN. Ann Thorac Surg; 2017 Sep 15; 104(3):751-759. PubMed ID: 28483152 [Abstract] [Full Text] [Related]
15. Mid-term results of freestyle aortic stentless bioprosthetic valve: clinical impact of quantitative analysis of in-vivo three-dimensional flow velocity profile by magnetic resonance imaging. Matsue H, Sawa Y, Matsumiya G, Matsuda H, Hamada S. J Heart Valve Dis; 2005 Sep 15; 14(5):630-6. PubMed ID: 16245502 [Abstract] [Full Text] [Related]
16. Direction and magnitude of blood flow shear stresses on the leaflets of aortic valves: is there a link with valve calcification? Ge L, Sotiropoulos F. J Biomech Eng; 2010 Jan 15; 132(1):014505. PubMed ID: 20524753 [Abstract] [Full Text] [Related]
17. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve. Xuan Y, Krishnan K, Ye J, Dvir D, Guccione JM, Ge L, Tseng EE. J Thorac Cardiovasc Surg; 2017 May 15; 153(5):1065-1073. PubMed ID: 28108064 [Abstract] [Full Text] [Related]