These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


208 related items for PubMed ID: 19454009

  • 1. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.
    Marqué S, Cariou A, Chiche JD, Squara P.
    Crit Care; 2009; 13(3):R73. PubMed ID: 19454009
    [Abstract] [Full Text] [Related]

  • 2. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter.
    Lamia B, Kim HK, Severyn DA, Pinsky MR.
    J Clin Monit Comput; 2018 Feb; 32(1):33-43. PubMed ID: 28188408
    [Abstract] [Full Text] [Related]

  • 3. Noninvasive cardiac output monitoring (NICOM): a clinical validation.
    Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C.
    Intensive Care Med; 2007 Jul; 33(7):1191-1194. PubMed ID: 17458538
    [Abstract] [Full Text] [Related]

  • 4. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.
    Button D, Weibel L, Reuthebuch O, Genoni M, Zollinger A, Hofer CK.
    Br J Anaesth; 2007 Sep; 99(3):329-36. PubMed ID: 17631509
    [Abstract] [Full Text] [Related]

  • 5. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo.
    Marqué S, Gros A, Chimot L, Gacouin A, Lavoué S, Camus C, Le Tulzo Y.
    J Clin Monit Comput; 2013 Jun; 27(3):273-9. PubMed ID: 23361128
    [Abstract] [Full Text] [Related]

  • 6. Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution.
    Hamm JB, Nguyen BV, Kiss G, Wargnier JP, Jauffroy A, Helaine L, Arvieux CC, Gueret G.
    Anaesth Intensive Care; 2010 Mar; 38(2):295-301. PubMed ID: 20369763
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers.
    Squara P, Rotcajg D, Denjean D, Estagnasie P, Brusset A.
    Crit Care; 2009 Mar; 13(4):R125. PubMed ID: 19638227
    [Abstract] [Full Text] [Related]

  • 9. Evaluation of the non-calibrated pulse contour cardiac output monitor FloTrac/Vigileo against thermodilution in standing horses.
    Kutter AP, Bettschart-Wolfensberger R, Schwarzwald CC, Portier KG, Ringer SK.
    Vet Anaesth Analg; 2016 Mar; 43(2):153-62. PubMed ID: 26095722
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography.
    Sun Y, Wu C, Wu JZ, Wang SS, Bai J, Zhu M, Zhang YQ, Zhang MZ.
    Paediatr Anaesth; 2015 Feb; 25(2):167-73. PubMed ID: 25039420
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Accuracy of Vigileo/Flotrac monitoring system in morbidly obese patients.
    Tejedor A, Rivas E, Ríos J, Arismendi E, Martinez-Palli G, Delgado S, Balust J.
    J Crit Care; 2015 Jun; 30(3):562-6. PubMed ID: 25735614
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach.
    Desebbe O, Henaine R, Keller G, Koffel C, Garcia H, Rosamel P, Obadia JF, Bastien O, Lehot JJ, Haftek M, Critchley LA.
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1122-7. PubMed ID: 24011911
    [Abstract] [Full Text] [Related]

  • 17. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients.
    Bendjelid K, Marx G, Kiefer N, Simon TP, Geisen M, Hoeft A, Siegenthaler N, Hofer CK.
    Br J Anaesth; 2013 Oct; 111(4):573-9. PubMed ID: 23625132
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.