These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


1724 related items for PubMed ID: 19590115

  • 21. Energy-resolved computed tomography: first experimental results.
    Shikhaliev PM.
    Phys Med Biol; 2008 Oct 21; 53(20):5595-613. PubMed ID: 18799830
    [Abstract] [Full Text] [Related]

  • 22. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1.
    Illers H, Buhr E, Hoeschen C.
    Radiat Prot Dosimetry; 2005 Oct 21; 114(1-3):39-44. PubMed ID: 15933079
    [Abstract] [Full Text] [Related]

  • 23. Determining air kerma from pixel values in digital mammography.
    Toroi P, Nieminen MT, Tenkanen-Rautakoski P, Varjonen M.
    Phys Med Biol; 2009 Jun 21; 54(12):3865-79. PubMed ID: 19491454
    [Abstract] [Full Text] [Related]

  • 24.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 25. Application of European protocol in the evaluation of contrast-to-noise ratio and mean glandular dose for two digital mammography systems.
    Muhogora WE, Devetti A, Padovani R, Msaki P, Bonutti F.
    Radiat Prot Dosimetry; 2008 Jun 21; 129(1-3):231-6. PubMed ID: 18283065
    [Abstract] [Full Text] [Related]

  • 26.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 27.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 28. AEC set-up optimisation with computed radiography imaging.
    Mazzocchi S, Belli G, Busoni S, Gori C, Menchi I, Salucci P, Taddeucci A, Zatelli G.
    Radiat Prot Dosimetry; 2005 Jun 21; 117(1-3):169-73. PubMed ID: 16461503
    [Abstract] [Full Text] [Related]

  • 29. Imaging performance of the hybrid pixel detectors XPAD3-S.
    Brunner FC, Clemens JC, Hemmer C, Morel C.
    Phys Med Biol; 2009 Mar 21; 54(6):1773-89. PubMed ID: 19258683
    [Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31. Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system.
    Mackenzie A, Dance DR, Workman A, Yip M, Wells K, Young KC.
    Med Phys; 2012 May 21; 39(5):2721-34. PubMed ID: 22559643
    [Abstract] [Full Text] [Related]

  • 32. Physical characterization of a high-resolution CCD detector for mammography.
    Elbakri IA, Tesic MM, Xiong Q.
    Phys Med Biol; 2007 Apr 21; 52(8):2171-83. PubMed ID: 17404462
    [Abstract] [Full Text] [Related]

  • 33. Management of pediatric radiation dose using Philips digital radiography.
    Neitzel U.
    Pediatr Radiol; 2004 Oct 21; 34 Suppl 3():S227-33; discussion S234-41. PubMed ID: 15558266
    [Abstract] [Full Text] [Related]

  • 34. [Physical imaging properties of a flat panel X-ray detector system].
    Yoshida A, Nakamura S, Nishihara S, Kohama C, Takahata A, Fujikawa K.
    Igaku Butsuri; 2002 Oct 21; 22(4):246-54. PubMed ID: 12766270
    [Abstract] [Full Text] [Related]

  • 35.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 36. Seven general radiography x-ray detectors with pixel sizes ranging from 175 to 76μm: technical evaluation with the focus on orthopaedic imaging.
    Marshall NW, Vandenbroucke D, Cockmartin L, Wanninger F, Smet M, Feng Y, Ni Y, Bosmans H.
    Phys Med Biol; 2023 Sep 20; 68(19):. PubMed ID: 37659394
    [Abstract] [Full Text] [Related]

  • 37. Automatic exposure control calibration and optimisation for abdomen, pelvis and lumbar spine imaging with an Agfa computed radiography system.
    Moore CS, Wood TJ, Avery G, Balcam S, Needler L, Joshi H, Saunderson JR, Beavis AW.
    Phys Med Biol; 2016 Nov 07; 61(21):N551-N564. PubMed ID: 27716642
    [Abstract] [Full Text] [Related]

  • 38.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 39. Status and prospects of digital detector technology for CR and DR.
    Neitzel U.
    Radiat Prot Dosimetry; 2005 Nov 07; 114(1-3):32-8. PubMed ID: 15933078
    [Abstract] [Full Text] [Related]

  • 40. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.
    Roessl E, Brendel B, Engel KJ, Schlomka JP, Thran A, Proksa R.
    IEEE Trans Med Imaging; 2011 Sep 07; 30(9):1678-90. PubMed ID: 21507770
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 87.