These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Left ventricular mass regression one year after transcatheter aortic valve implantation. Tzikas A, Geleijnse ML, Van Mieghem NM, Schultz CJ, Nuis RJ, van Dalen BM, Sarno G, van Domburg RT, Serruys PW, de Jaegere PP. Ann Thorac Surg; 2011 Mar; 91(3):685-91. PubMed ID: 21352980 [Abstract] [Full Text] [Related]
5. Left ventricular mass regression is independent of gradient drop and effective orifice area after aortic valve replacement with a porcine bioprosthesis. Sádaba JR, Herregods MC, Bogaert J, Harringer W, Gerosa G. J Heart Valve Dis; 2012 Nov; 21(6):788-94. PubMed ID: 23409363 [Abstract] [Full Text] [Related]
6. Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome. Bové T, Van Belleghem Y, François K, Caes F, Van Overbeke H, Van Nooten G. Eur J Cardiothorac Surg; 2006 Nov; 30(5):706-13. PubMed ID: 16950630 [Abstract] [Full Text] [Related]
12. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients. Haverich A, Wahlers TC, Borger MA, Shrestha M, Kocher AA, Walther T, Roth M, Misfeld M, Mohr FW, Kempfert J, Dohmen PM, Schmitz C, Rahmanian P, Wiedemann D, Duhay FG, Laufer G. J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2854-60. PubMed ID: 25218544 [Abstract] [Full Text] [Related]
13. Impact of the improvement of valve area achieved with aortic valve replacement on the regression of left ventricular hypertrophy in patients with pure aortic stenosis. Tasca G, Brunelli F, Cirillo M, Dalla Tomba M, Mhagna Z, Troise G, Quaini E. Ann Thorac Surg; 2005 Apr; 79(4):1291-6; discussion 1296. PubMed ID: 15797064 [Abstract] [Full Text] [Related]
14. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression. Alassal MA, Ibrahim BM, Elsadeck N. Asian Cardiovasc Thorac Ann; 2014 Jun; 22(5):546-50. PubMed ID: 24867028 [Abstract] [Full Text] [Related]
15. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus. Wagner IM, Eichinger WB, Bleiziffer S, Botzenhardt F, Gebauer I, Guenzinger R, Bauernschmitt R, Lange R. J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435 [Abstract] [Full Text] [Related]
19. Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosis. Bech-Hanssen O, Caidahl K, Wall B, Mykén P, Larsson S, Wallentin I. J Thorac Cardiovasc Surg; 1999 Jul; 118(1):57-65. PubMed ID: 10384185 [Abstract] [Full Text] [Related]
20. Clinical Impact of Changes in Left Ventricular Function After Aortic Valve Replacement: Analysis From 3112 Patients. Une D, Mesana L, Chan V, Maklin M, Chan R, Masters RG, Mesana TG, Ruel M. Circulation; 2015 Aug 25; 132(8):741-7. PubMed ID: 26304665 [Abstract] [Full Text] [Related] Page: [Next] [New Search]