These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


575 related items for PubMed ID: 19837308

  • 1. Biomechanical analysis of miniplate osteosynthesis for fractures of the atrophic mandible.
    Sugiura T, Yamamoto K, Murakami K, Kawakami M, Kang YB, Tsutsumi S, Kirita T.
    J Oral Maxillofac Surg; 2009 Nov; 67(11):2397-403. PubMed ID: 19837308
    [Abstract] [Full Text] [Related]

  • 2. Three-dimensional finite element analysis of mechanical stress in symphyseal fractured human mandible reduced with miniplates during mastication.
    Wang H, Ji B, Jiang W, Liu L, Zhang P, Tang W, Tian W, Fan Y.
    J Oral Maxillofac Surg; 2010 Jul; 68(7):1585-92. PubMed ID: 20434254
    [Abstract] [Full Text] [Related]

  • 3. Comparative finite element analysis of the biomechanical stability of 2.0 fixation plates in atrophic mandibular fractures.
    Vajgel A, Camargo IB, Willmersdorf RB, de Melo TM, Laureano Filho JR, Vasconcellos RJ.
    J Oral Maxillofac Surg; 2013 Feb; 71(2):335-42. PubMed ID: 23351762
    [Abstract] [Full Text] [Related]

  • 4. An in vitro evaluation of miniplate fixation techniques for fractures of the atrophic edentulous mandible.
    Choi BH, Huh JY, Suh CH, Kim KN.
    Int J Oral Maxillofac Surg; 2005 Mar; 34(2):174-7. PubMed ID: 15695047
    [Abstract] [Full Text] [Related]

  • 5. A biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method.
    Ji B, Wang C, Liu L, Long J, Tian W, Wang H.
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Mar; 109(3):e21-7. PubMed ID: 20219581
    [Abstract] [Full Text] [Related]

  • 6. Comparative evaluation of different miniplates for internal fixation of mandible fractures using finite element analysis.
    Arbag H, Korkmaz HH, Ozturk K, Uyar Y.
    J Oral Maxillofac Surg; 2008 Jun; 66(6):1225-32. PubMed ID: 18486788
    [Abstract] [Full Text] [Related]

  • 7. A biomechanical comparison of 2 techniques for reconstructing atrophic edentulous mandible fractures.
    Madsen MJ, Haug RH.
    J Oral Maxillofac Surg; 2006 Mar; 64(3):457-65. PubMed ID: 16487809
    [Abstract] [Full Text] [Related]

  • 8. A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process.
    Wagner A, Krach W, Schicho K, Undt G, Ploder O, Ewers R.
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2002 Dec; 94(6):678-86. PubMed ID: 12464890
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model.
    Sikes JW, Smith BR, Mukherjee DP.
    J Oral Maxillofac Surg; 2000 Jan; 58(1):56-61; discussion 62. PubMed ID: 10632166
    [Abstract] [Full Text] [Related]

  • 15. Biomechanical comparison of a new technique of mandibular angle fractures: biplanar and bicortical superior proximal 3 holes and bicortical inferior plate fixation.
    Turgut G, Kayali MU, Soydan AT, Gündüz O, Salman S, Oktar F, Baş L.
    J Craniofac Surg; 2008 Mar; 19(2):428-32. PubMed ID: 18362721
    [Abstract] [Full Text] [Related]

  • 16. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle.
    Aquilina P, Chamoli U, Parr WC, Clausen PD, Wroe S.
    Br J Oral Maxillofac Surg; 2013 Jun; 51(4):326-31. PubMed ID: 22981343
    [Abstract] [Full Text] [Related]

  • 17. Combination of microplate and miniplate for osteosynthesis of mandibular fractures: an experimental study.
    Feller KU, Richter G, Schneider M, Eckelt U.
    Int J Oral Maxillofac Surg; 2002 Feb; 31(1):78-83. PubMed ID: 11936405
    [Abstract] [Full Text] [Related]

  • 18. [Experimental study on the biomechanical stability of different internal fixators for use in the mandible].
    Piffkò J, Homann Ch, Schuon R, Joos U, Meyer U.
    Mund Kiefer Gesichtschir; 2003 Jan; 7(1):1-6. PubMed ID: 12556978
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of labial versus labio-inferior lines of osteosynthesis using 3D miniplate for fractures of anterior mandible: A finite element analysis with a pilot clinical trial.
    Ponvel K, Panneerselvam E, Balasubramanian S, Krishna Kumar Raja VB.
    Chin J Traumatol; 2019 Oct; 22(5):261-269. PubMed ID: 31493976
    [Abstract] [Full Text] [Related]

  • 20. Miniplate osteosynthesis of fractures of the edentulous mandible.
    Mugino H, Takagi S, Oya R, Nakamura S, Ikemura K.
    Clin Oral Investig; 2005 Dec; 9(4):266-70. PubMed ID: 16311742
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 29.