These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


201 related items for PubMed ID: 19847883

  • 1. Evaluation of a dry format reagent alternative for CD4 T-cell enumeration for the FACSCount system: a report on a Moroccan-Canadian study.
    Bergeron M, Ding T, Elharti E, Oumzil H, Soucy N, Harmouche H, Chaouch S, Aouad RE, Chabot C, Mandy F.
    Cytometry B Clin Cytom; 2010 May; 78(3):188-93. PubMed ID: 19847883
    [Abstract] [Full Text] [Related]

  • 2. New BD FACSCount CD4 reagent system for simultaneous enumeration of percent and absolute CD4 T-lymphocytes in HIV-1-infected pediatric patients.
    Pattanapanyasat K, Sukapirom K, Kowawisatsut L, Thepthai C.
    Cytometry B Clin Cytom; 2008 May; 74 Suppl 1():S98-106. PubMed ID: 18307252
    [Abstract] [Full Text] [Related]

  • 3. Evaluation of a flow cytometry method for CD4 T cell enumeration based on volumetric primary CD4 gating using thermoresistant reagents.
    Dieye TN, Diaw PA, Daneau G, Wade D, Sylla Niang M, Camara M, Diallo AA, Toure Kane C, Diop Ndiaye H, Mbengue B, Dieye A, Kestens L, Mboup S.
    J Immunol Methods; 2011 Sep 30; 372(1-2):7-13. PubMed ID: 21835181
    [Abstract] [Full Text] [Related]

  • 4. Evaluation of a dry format reagent for CD4+ and CD8+ T-cell enumeration with FACSCount and Guava PCA [corrected].
    Sachithanandham J, Solomon K, Prasannakumar S, Nithyandham G, Kannangai R.
    Indian J Med Microbiol; 2011 Sep 30; 29(4):401-5. PubMed ID: 22120802
    [Abstract] [Full Text] [Related]

  • 5. Evaluation of a single-platform microcapillary flow cytometer for enumeration of absolute CD4+ T-lymphocyte counts in HIV-1 infected Thai patients.
    Pattanapanyasat K, Phuang-Ngern Y, Lerdwana S, Wasinrapee P, Sakulploy N, Noulsri E, Thepthai C, McNicholl JM.
    Cytometry B Clin Cytom; 2007 Sep 30; 72(5):387-96. PubMed ID: 17474130
    [Abstract] [Full Text] [Related]

  • 6. Performance of the Panleucogating protocol for CD4+ T cell enumeration in an HIV dedicated laboratory facility in Barbados.
    Sippy-Chatrani N, Marshall S, Branch S, Carmichael-Simmons K, Landis RC, Abayomi A.
    Cytometry B Clin Cytom; 2008 Sep 30; 74 Suppl 1():S65-8. PubMed ID: 18228556
    [Abstract] [Full Text] [Related]

  • 7. Enumeration of the absolute CD4 T-lymphocyte count by cell-bead assay.
    Nantakomol D, Nuchnoi P, Noulsri E, Lerdwana S, Krisin S, Chanprasert S, Pattanapanyasat K.
    Cytometry B Clin Cytom; 2010 Jul 30; 78(4):260-6. PubMed ID: 20309993
    [Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9. A multicenter evaluation of the PanLeucogating method and the use of generic monoclonal antibody reagents for CD4 enumeration in HIV-infected patients in Thailand.
    Pattanapanyasat K, Shain H, Noulsri E, Lerdwana S, Thepthai C, Prasertsilpa V, Likanonsakul S, Yothipitak P, Nookhai S, Eksaengsri A.
    Cytometry B Clin Cytom; 2005 May 30; 65(1):29-36. PubMed ID: 15800883
    [Abstract] [Full Text] [Related]

  • 10. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings.
    Li X, Ymeti A, Lunter B, Breukers C, Tibbe AG, Terstappen LW, Greve J.
    Cytometry B Clin Cytom; 2007 Sep 30; 72(5):397-407. PubMed ID: 17311352
    [Abstract] [Full Text] [Related]

  • 11. CD4 estimating reagents in dry format are compatible with conventional flow cytometer; FACSCalibur for estimation of absolute CD4 count & percentages.
    Thakar M, Mahajan B, Joshi T, Sane S, Paranjape R.
    Indian J Med Res; 2013 Feb 30; 137(2):346-55. PubMed ID: 23563379
    [Abstract] [Full Text] [Related]

  • 12. Absolute and percent CD4+ T-cell enumeration by flow cytometry using capillary blood.
    Sitoe N, Luecke E, Tembe N, Matavele R, Cumbane V, Macassa E, Vaz P, Sheppard H, Jani IV.
    J Immunol Methods; 2011 Sep 30; 372(1-2):1-6. PubMed ID: 21787779
    [Abstract] [Full Text] [Related]

  • 13. Using BD Vacutainer CD4 Stabilization Tubes for Absolute Cluster of Differentiation Type 4 Cell Count Measurement on BD FacsCount and Partec Cyflow Cytometers: A Method Comparison Study from Zimbabwe.
    Vogt F, Van den Bergh R, Bernasconi A, Moyo B, Havazvidi L, Bastard M, Flevaud L, Taziwa F, Makondo E, Mtapuri-Zinyowera S.
    PLoS One; 2015 Sep 30; 10(8):e0136537. PubMed ID: 26295802
    [Abstract] [Full Text] [Related]

  • 14. Performance of the BD FACSPresto near to patient analyzer in comparison with representative conventional CD4 instruments in Cameroon.
    Sagnia B, Mbakop Ghomsi F, Gutierrez A, Sosso S, Kamgaing R, Nanfack AJ, Nji N, Ambada G, Lissom A, Tchouangueu TF, Ngu Ndengkoh L, Domkam I, Nchinda G, Ndjolo A.
    AIDS Res Ther; 2020 Aug 17; 17(1):53. PubMed ID: 32799909
    [Abstract] [Full Text] [Related]

  • 15. African regional external quality assessment for CD4 T-cell enumeration: development, outcomes, and performance of laboratories.
    Glencross DK, Aggett HM, Stevens WS, Mandy F.
    Cytometry B Clin Cytom; 2008 Aug 17; 74 Suppl 1():S69-79. PubMed ID: 18228560
    [Abstract] [Full Text] [Related]

  • 16. Flow rate calibration II: a clinical evaluation study using PanLeucoGating as a single-platform protocol.
    Storie I, Sawle A, Whitby L, Goodfellow K, Granger V, Reilly JT, Barnett D.
    Cytometry B Clin Cytom; 2003 Sep 17; 55(1):8-13. PubMed ID: 12949954
    [Abstract] [Full Text] [Related]

  • 17. CD4+ T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in service.
    Pattanapanyasat K, Chimma P, Sratongno P, Lerdwana S.
    Cytometry B Clin Cytom; 2008 Sep 17; 74(5):310-8. PubMed ID: 18481294
    [Abstract] [Full Text] [Related]

  • 18. CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration.
    Glencross D, Scott LE, Jani IV, Barnett D, Janossy G.
    Cytometry; 2002 Apr 15; 50(2):69-77. PubMed ID: 12116348
    [Abstract] [Full Text] [Related]

  • 19. Helper T-lymphocyte count. TRAx CD4 test kit versus conventional flow cytometry.
    Saah AJ, Spruill C, Hoover DR, Prevots R, Taylor E, Margolick JB, Vlahov D.
    Arch Pathol Lab Med; 1997 Sep 15; 121(9):960-2. PubMed ID: 9302928
    [Abstract] [Full Text] [Related]

  • 20. Panleucogating as an accurate and affordable flow cytometric protocol to analyse lymphocyte subsets among HIV-positive patients on HAART treatment in Mozambique.
    Ceffa S, Erba F, Assane M, Coelho E, Calgaro M, Brando B.
    J Biol Regul Homeost Agents; 2005 Sep 15; 19(3-4):169-75. PubMed ID: 16602633
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.