These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
169 related items for PubMed ID: 1984881
1. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Chafizadeh ER, Zoghbi WA. Circulation; 1991 Jan; 83(1):213-23. PubMed ID: 1984881 [Abstract] [Full Text] [Related]
2. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L, Carratino L, De Gaetano G, Piazza R, Calisi P, Passerone G, Lucatti A. G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [Abstract] [Full Text] [Related]
3. Doppler assessment of prosthetic valve orifice area. An in vitro study. Baumgartner H, Khan SS, DeRobertis M, Czer LS, Maurer G. Circulation; 1992 Jun; 85(6):2275-83. PubMed ID: 1591841 [Abstract] [Full Text] [Related]
4. Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: an in vivo and in vitro study. Bech-Hanssen O, Caidahl K, Wallentin I, Ask P, Wranne B. J Thorac Cardiovasc Surg; 2001 Aug; 122(2):287-95. PubMed ID: 11479501 [Abstract] [Full Text] [Related]
5. Doppler echocardiographic assessment with the continuity equation of St. Jude Medical mechanical prostheses in the mitral valve position. Bitar JN, Lechin ME, Salazar G, Zoghbi WA. Am J Cardiol; 1995 Aug 01; 76(4):287-93. PubMed ID: 7618626 [Abstract] [Full Text] [Related]
6. [Limitation of Doppler echocardiography in evaluation of aortic valve prostheses]]. Geibel A, Kasper W, Fraedrich G, Konstantinides S, Schöllhorn J, Tiede N, Just H. Z Kardiol; 1993 Mar 01; 82(3):175-80. PubMed ID: 8475654 [Abstract] [Full Text] [Related]
7. Impact of size mismatch and left ventricular function on performance of the St. Jude disc valve after aortic valve replacement. Lund O, Emmertsen K, Nielsen TT, Jensen FT, Flø C, Pilegaard HK, Rasmussen BS, Hansen OK, Kristensen LH. Ann Thorac Surg; 1997 May 01; 63(5):1227-34. PubMed ID: 9146307 [Abstract] [Full Text] [Related]
8. Application of the continuity equation and valve resistance to the evaluation of St. Jude Medical prosthetic aortic valve dysfunction. Saad RM, Barbetseas J, Olmos L, Rubio N, Zoghbi WA. Am J Cardiol; 1997 Nov 01; 80(9):1239-42. PubMed ID: 9359564 [Abstract] [Full Text] [Related]
9. Analysis of Doppler-obtained velocity curves in functional evaluation of mechanical prosthetic valves in the mitral and aortic positions. Goldrath N, Zimes R, Vered Z. J Am Soc Echocardiogr; 1988 Nov 01; 1(3):211-25. PubMed ID: 3272769 [Abstract] [Full Text] [Related]
10. Improved Doppler assessment of the Bjork-Shiley mitral prosthesis using the continuity equation. Mohan JC, Agrawal R, Arora R, Khalilullah M. Int J Cardiol; 1994 Mar 01; 43(3):321-6. PubMed ID: 8181890 [Abstract] [Full Text] [Related]
11. Assessment of the St. Jude Medical Regent prosthetic valve by continuous-wave Doppler and dobutamine stress echocardiography. Sezai A, Kasamaki Y, Abe K, Hata M, Sekino H, Shimura K, Minami K. Ann Thorac Surg; 2010 Jan 01; 89(1):87-92. PubMed ID: 20103211 [Abstract] [Full Text] [Related]
12. Determination of aortic valve area by two-dimensional and Doppler echocardiography in patients with normal and stenotic bioprosthetic valves. Rothbart RM, Castriz JL, Harding LV, Russo CD, Teague SM. J Am Coll Cardiol; 1990 Mar 15; 15(4):817-24. PubMed ID: 2307793 [Abstract] [Full Text] [Related]
15. Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions. Badano L, Mocchegiani R, Bertoli D, DeGaetano G, Carratino L, Pasetti L, Caudullo M, Budini A, Mannello B, Passerone G. J Am Soc Echocardiogr; 1997 Mar 15; 10(6):632-43. PubMed ID: 9282353 [Abstract] [Full Text] [Related]
16. Clinical experience and Doppler echocardiographic assessment of the first one hundred ATS AP (advanced performance) prosthetic valve in the aortic position. Jazayeri S, Gomez MC, Tatou E, Ecarnot A, Saleh M, Bouchot O, Renaud C, Brenot R, David M. J Heart Valve Dis; 2003 Sep 15; 12(5):628-34; discussion 634. PubMed ID: 14565717 [Abstract] [Full Text] [Related]
17. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography. Panidis IP, Ross J, Mintz GS. J Am Coll Cardiol; 1986 Aug 15; 8(2):317-26. PubMed ID: 2942593 [Abstract] [Full Text] [Related]
18. Doppler echocardiographic assessment of TTK Chitra prosthetic heart valve in the mitral position. Namboodiri N, Shajeem O, Tharakan JA, Sankarkumar R, Titus T, Valaparambil A, Sivasankaran S, Krishnamoorthy KM, Harikrishnan SP, Dora SK. Eur J Echocardiogr; 2008 Sep 15; 9(5):599-604. PubMed ID: 18296411 [Abstract] [Full Text] [Related]